2023-4-1 3.226.122.122
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 2951.14-2008
GB/T 2951.14-2008   Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature (English Version)
Standard No.: GB/T 2951.14-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5000 words Price(USD):130.0 remind me the price change

Email:

Implemented on:2009-4-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 2951.14-2008
English Name: Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature
Chinese Name: 电缆和光缆绝缘和护套材料通用试验方法 第14部分:通用试验方法 低温试验
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
Issued by: AQSIQ, SAC
Issued on: 2008-6-26
Implemented on: 2009-4-1
Status: valid
Superseding:GB/T 2951.4-1997 Common test methods for insulating and sheathing materials of electric cables Part 1: Methods for general application
Language: English
File Format: PDF
Word Count: 5000 words
Price(USD): 130.0
Delivery: via email in 1 business day
1 Scope GB/T 2951 specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables and optical cables for power distribution and telecommunications including cables used on ships, and in offshore applications. This part of GB/T 2951 gives the methods for tests at low temperature which apply to the insulating and sheathing PVC and PE compounds and of wires, electric and optical cables. 1.1 Normative References The following normative document contains provisions which, through reference in this text, constitute provisions of this part of GB/T 2951. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric Cables and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:1993, IDT) 2 Test Values Full test conditions (such as temperatures, durations, etc.) and full test requirements are not specified in this standard; it is intended that they should be specified by the standard dealing with the relevant type of cable. Any test requirements which are given in this part may be modified by the relevant cable standard to suit the needs of a particular type of cable.
Foreword II 1 Scope 1.1 Normative References 2 Test Values 3 Applicability 4 Type Tests and Other Tests 5 Pre-conditioning 6 Test Temperature 7 Median Value 8 Tests at Low Temperature 8.1 Bending Test at Low Temperature for Insulations 8.2 Bending Test at Low Temperature for Sheaths 8.3 Elongation Test at Low Temperature for Insulations 8.4 Elongation Test at Low Temperature for Sheaths 8.5 Impact Test at Low Temperature for PVC Insulations and Sheaths
GB/T 2951.14-2008 is referred in:
* GB/T 9330.2-2008 Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB/T 9330.2-2008 Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
* GB/T 12706.2-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 2: Cables for rated voltages from 6kV (Um=7.2kV) up t
* DL/T 5253-2010 Design technique and construction regulations for low-voltage distribution network based on the overhead bundled insulated conductors
*CQC 1104-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems
*CQC 1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 1: General Requiremen
*TB/T 1484.2-2010 Specification for cables on board rolling stock - Part 2: Thin wall insulation cables
*TB/T 1484.1-2010 Specification for cables on board rolling stock - Part 1: Standard wall insulation cables up to AC 3 kV
*MH/T 6049-2008 Underground Electrical Cable for Airport Lighting Circuits
*GB/T 18890.2-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables
*GB/T 18890.1-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 1:Test methods and requirements
*JB/T 8734.1-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 1:General requirements
*JB/T 8734.2-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 2:Insulated cables and wires for fixed wiring
*JB/T 8734.5-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 5: Screened wires
*TB/T 1484.2-2017 Specification for cables on board rolling stock-Part 2:30kVsingle phase power cables
*GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 1: Cables for rated voltage of 1kV (Um=1.2kV) and 3kV (Um=3.6kV)
*GB/T 33606-2017 Flexible and torsion resistant cables of rated voltages from 6 kV(Um=7.2 kV)up to 35 kV(Um=40.5 kV)for wind power generation
*GB/T 12706.3-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 3: Cables for rated voltage of 35kV(Um=40.5kV)
*GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
*GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2: Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
*GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)—Part 3: Cables for rated voltages of 35kV(Um=40.5kV)
*GB/T 28427-2012 27.5 kV single-phase AC XLPE insulation cable and accessories for electrification railway
*GB/T 11017.1-2014 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110 kV(Um=126 kV)―Part 1:Test methods and requirements
*GB/T 11017.2-2014 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110 kV (Um=126 kV)―Part 2:Power cables
*GB/T 29543-2013 Wind turbine generator systems for cold environments
Code of China
Standard
GB/T 2951.14-2008  Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature (English Version)
Standard No.GB/T 2951.14-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)130.0
Implemented on2009-4-1
Deliveryvia email in 1 business day
Detail of GB/T 2951.14-2008
Standard No.
GB/T 2951.14-2008
English Name
Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature
Chinese Name
电缆和光缆绝缘和护套材料通用试验方法 第14部分:通用试验方法 低温试验
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2008-6-26
Implemented on
2009-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 2951.4-1997 Common test methods for insulating and sheathing materials of electric cables Part 1: Methods for general application
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
130.0
Keywords
GB/T 2951.14-2008, GB 2951.14-2008, GBT 2951.14-2008, GB/T2951.14-2008, GB/T 2951.14, GB/T2951.14, GB2951.14-2008, GB 2951.14, GB2951.14, GBT2951.14-2008, GBT 2951.14, GBT2951.14
Introduction of GB/T 2951.14-2008
1 Scope GB/T 2951 specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables and optical cables for power distribution and telecommunications including cables used on ships, and in offshore applications. This part of GB/T 2951 gives the methods for tests at low temperature which apply to the insulating and sheathing PVC and PE compounds and of wires, electric and optical cables. 1.1 Normative References The following normative document contains provisions which, through reference in this text, constitute provisions of this part of GB/T 2951. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric Cables and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:1993, IDT) 2 Test Values Full test conditions (such as temperatures, durations, etc.) and full test requirements are not specified in this standard; it is intended that they should be specified by the standard dealing with the relevant type of cable. Any test requirements which are given in this part may be modified by the relevant cable standard to suit the needs of a particular type of cable.
Contents of GB/T 2951.14-2008
Foreword II 1 Scope 1.1 Normative References 2 Test Values 3 Applicability 4 Type Tests and Other Tests 5 Pre-conditioning 6 Test Temperature 7 Median Value 8 Tests at Low Temperature 8.1 Bending Test at Low Temperature for Insulations 8.2 Bending Test at Low Temperature for Sheaths 8.3 Elongation Test at Low Temperature for Insulations 8.4 Elongation Test at Low Temperature for Sheaths 8.5 Impact Test at Low Temperature for PVC Insulations and Sheaths
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 2951.14-2008, GB 2951.14-2008, GBT 2951.14-2008, GB/T2951.14-2008, GB/T 2951.14, GB/T2951.14, GB2951.14-2008, GB 2951.14, GB2951.14, GBT2951.14-2008, GBT 2951.14, GBT2951.14