2025-5-14 18.97.14.88
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GA 1288-2016
GA 1288-2016   Heptafluoropropane foam fire extinguishing system (English Version)
Standard No.: GA 1288-2016 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 14500 words Price(USD):430.0 remind me the price change

Email:

Implemented on:2016-8-10 Delivery: via email in 1 business day
,,
Standard No.: GA 1288-2016
English Name: Heptafluoropropane foam fire extinguishing system
Chinese Name: 七氟丙烷泡沫灭火系统
Chinese Classification: C84    Fire-fighting equipment and devices
Professional Classification: GA    Professional Standard - Security
ICS Classification: 13.220.10 13.220.10    Fire-fighting 13.220.10
Issued by: Ministry of Public Security
Issued on: 2016-03-10
Implemented on: 2016-8-10
Status: superseded
Superseded by:XF 1288-2016 Heptafluoropropane foam fire extinguishing system
Superseded on:2016-8-10
Language: English
File Format: PDF
Word Count: 14500 words
Price(USD): 430.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. In this standard, Clauses 5 and 7 are compulsory, and others are voluntary. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the Fire Department of Ministry of Public Security. This standard is under the jurisdiction of SAC/TC 113/SC 2 Technical Subcommittee on Fixed Fire Extinguishing System of National Technical Committee on Fire Protection of Standardization Administration of China. This standard is issued for the first time. Introduction The issuing body of this document draws attention to the fact that claims of compliance with this document may involve the use of relevant patents (with the patent numbers of ZL 200810120340.2 and ZL 200820163235.2). The issuing body of this document takes no position concerning the evidence, validity and scope of this patent right. The patent holder has assured the issuing body of this document that he/she allows any organization or individual to apply the patents (with the patent numbers of ZL 200810120340.2 and ZL 200820163235.2) for free on the basis of reasonableness and nondiscrimination during implementing this professional standard. The patent holders’ statements have been put on records at the issuing body of this document. The relevant information may be obtained through the following contact information: Patentee: Hangzhou New Epoch Safety Products Co., Ltd. and Hangzhou New Epoch Fire Protection Science & Technology Co., Ltd. Address: No. 3, Tangning Road, Linping Development Zone, Yuhang District, Hangzhou, Zhejiang, 311100. Attention is drawn to the possibility that some other contents of this document may also be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. Heptafluoropropane foam fire extinguishing system 1 Scope This standard specifies the terms and definitions, classification and model, technical requirements, test methods, inspection rules as well as marking, packaging, transport and storage of heptafluoropropane foam fire extinguishing system and components. This standard is applicable to the heptafluoropropane foam fire extinguishing system and components. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3222.2 Acoustics - Description, measurement and assessment of environmental noise - Part 2: Determination of environmental noise levels GB/T 3797 Electrical control assemblies GB 4208 Degrees of protection provided by enclosure (IP Code) GB/T 9969 General principles for preparation of instructions for use of industrial products GB 15308 Foam extinguishing agent GB 18614 Fire extinguishing agent heptafluoropropane (HFC227ea) GB 20031-2005 General technical specifications for foam fire extinguishing systems and components GB 25972-2010 Gas fire extinguishing systems and components GA 61-2010 General technical specifications of actuating and control devices of fixed extinguishing systems GA 834-2009 Foam-spray extinguishing equipments 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 heptafluoropropane foam fire extinguishing system fire extinguishing system which is composed of water supply system, foam concentrate storage tank, foam proportioning device, heptafluoropropane feeding device, heptafluoropropane proportioning device, heptafluoropropane foam maker, control cabinet, valve, pipeline, etc. and is able to generate heptafluoropropane foam 3.2 heptafluoropropane concentration volume percentage of liquid heptafluoropropane in heptafluoropropane foam mixture 3.3 heptafluoropropane proportioning device device for mixing liquid heptafluoropropane and foam mixture at a specified concentration 3.4 storage pressure equilibrium pressure in the heptafluoropropane storage container at 20℃ after it is filled with heptafluoropropane at the maximum filling density and pressurized 3.5 heptafluoropropane foam maker device for foaming and producing heptafluoropropane foam by gasification of liquid heptafluoropropane in heptafluoropropane foam mixture 3.6 maximum working pressure of system maximum working pressure of heptafluoropropane proportioning device 4 Classification and model 4.1 Classification 4.1.1 The heptafluoropropane foam fire extinguishing system may be classified by the type of foam proportioning device into: a) balanced type, with code of P; b) metering injection type, with code of J; c) pressure type, with code of Y; d) mechanical pumping type, with code of B; e) other types, with code of Q. 4.1.2 The heptafluoropropane foam fire extinguishing system may be classified by heptafluoropropane storage type into: a) external stored pressure type, with code of W; b) internal stored pressure type, not marked. 4.2 Model 4.2.1 System model The system shall be modeled following the following requirements: Example: PQF-WP/200/6/1.6 refers to external stored pressure heptafluoropropane foam fire extinguishing system with a maximum working pressure of 1.6 MPa, a foam concentration of 6%, a maximum flow of 200 L/s and a balanced foam proportioning device. 4.2.2 Component model See Annex A for the preparation method of component model. 5 Technical requirements 5.1 System 5.1.1 Main performance parameters See Table 1 for the main performance parameters of heptafluoropropane foam fire extinguishing system (hereinafter referred to as system). Table 1 Main performance parameters of system System working pressure range MPa System flow range L/s Heptafluoropropane concentration Foam concentrate concentration Continuous working time min Value published by the manufacturer Value published by the manufacturer 5% 3% and 6% ≥15 5.1.2 System composition 5.1.2.1 The system shall at least consist of foam concentrate storage tank, foam proportioning device, heptafluoropropane feeding device, heptafluoropropane proportioning device, heptafluoropropane foam maker, control cabinet, valve, pipeline, etc. 5.1.2.2 All components of the system shall be firmly fixed, reliably connected, installed at the correct position, reasonably arranged in an integrated way, and convenient for operation, inspection and maintenance. 5.1.3 Appearance All components of the system shall be free from any obvious processing defects or mechanical damages, and their external surfaces shall be subject to anti-corrosion treatment, and the anti-corrosion coating and plating shall be complete and even. 5.1.4 Marking 5.1.4.1 The name and filling pressure of the gas shall be marked on the front surface of the gas cylinder group, and the handwriting shall be clear and legible. 5.1.4.2 Each manually operated part of the system shall be marked with the operation method via texts and graphic symbols, and the proportioning device, check valve, etc. shall be marked with the medium flow direction. 5.1.4.3 The system shall be provided with permanent signs at conspicuous position, with the content at least covering product name, model and specification, number of standard executed, type of applicable foam concentrate, service temperature range, working pressure range of system, flow range of system, storage pressure of heptafluoropropane storage device, manufacturer, product number, date of manufacture, etc. The signs shall remain legible after being subjected to the salt spray corrosion test according to 6.11. 5.1.5 Start-up operation requirements 5.1.5.1 Start method The system shall be provided with automatic start, manual start and mechanical emergency start functions. For manual start and mechanical emergency start, effective measures shall be taken to prevent misoperation. 5.1.5.2 Delayed start function The automatic start of the system shall be provided with delayed start function. The delay time may be continuously adjustable from 0s to 30s; if step adjustment is adopted, the interval shall not be more than 10s. The delay time measurement error shall not be more than 20% of the set time. 5.1.5.3 Start-up operation The system shall be started in different ways, and its action shall be accurate, reliable and fault-free. 5.1.6 Fire extinguishing requirements Systems using alcohol-resistant foam concentrate shall be subjected to the test for extinguishing propylene oxide and n-pentane oil pan fire; systems using other types of foam concentrates shall be subjected to the test for extinguishing n-pentane oil pan fire. The fire extinguishing test shall be performed in accordance with 6.12, and the results shall meet the following requirements: a) the sprayed foam layer shall completely cover the fuel surface; b) the flame shall be completely extinguished by the end of the spray of the fire-extinguishing foam; c) after the fire is extinguished, the fuel covered by foam shall be free from reignition, burning or flashover; d) after the fire is extinguished, there shall be remaining fuel in the oil pan. 5.2 Foam extinguishing agent and heptafluoropropane extinguishing agent The foam extinguishing agent shall meet the requirements of GB 15308 and the heptafluoropropane extinguishing agent shall meet the requirements of GB 18614. 5.3 Foam proportioning device and foam concentrate storage tank 5.3.1 Foam proportioning device The foam proportioning device shall meet the requirements in 5.1 of GB 20031-2005. 5.3.2 Foam concentrate storage tank The foam concentrate storage tank shall meet the requirements in 5.1.2.3 or 5.3.7 of GB 20031-2005. 5.4 Heptafluoropropane proportioning device 5.4.1 Marking Permanent signs shall be provided at a prominent position on the enclosure of the heptafluoropropane proportioning device, with the flow direction of medium indicated by arrows. The sign shall at least indicate the following information: product name, specification and model, product number, working pressure range, flow range, heptafluoropropane concentration, executive standard, name or trademark of the manufacturer, etc. The signs shall remain legible after being subjected to the salt spray corrosion test according to 6.11. 5.4.2 Materials Parts and components that are in direct contact with the mixture of heptafluoropropane and foam shall be made of materials with a corrosion resistance not inferior to that of copper alloys. 5.4.3 Main performance parameters The main performance parameters of heptafluoropropane proportioning device shall meet the requirements in Table 2.   Table 2 Main performance parameters of heptafluoropropane proportioning device Inlet working pressure range MPa Flow range L/s Concentration Pressure loss MPa Value published by the manufacturer Value published by the manufacturer 5%~6% ≤0.2 5.4.4 Strength and sealing 5.4.4.1 Strength Carry out the strength test according to 6.2, during which the test pressure shall be 1.5 times the maximum working pressure and maintained for 5 min. After the test, there shall be no leakage, structural damage, permanent deformation or rupture of any component of the heptafluoropropane proportioning device. 5.4.4.2 Sealing Carry out the seal test according to 6.3, during which the test pressure shall be 1.1 times the maximum working pressure and maintained for 5 min. After the test, there shall be no leakage, deformation or damage of any component of the heptafluoropropane proportioning device.
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and model 5 Technical requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transport and storage Annex A (Normative) Method for preparation of component model Annex B (Normative) Test procedures and sample quantity for the system Annex C (Normative) Test procedures and sample quantity for heptafluoropropane proportioning device Annex D (Normative) Test procedures and sample quantity for heptafluoropropane foam maker Annex E (Normative) Test procedures and sample quantity for heptafluoropropane storage device Annex F (Normative) Test procedures and sample quantity for heptafluoropropane control valve Annex G (Normative) Test procedures and sample quantity for control cabinet
Referred in GA 1288-2016:
*GB/T 3222.2-2022 Acoustics—Description, measurement and assessment of environmental noise—Part 2: Determination of sound pressure levels
*GB/T 3797-2016 Electrical control assemblies
*GB 4208-2008 Degrees of Protection Provided By Enclosure (IP Code)
*GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
*GB 15308-2006 Foam extinguishing agent
*GB 18614-2012 Fire extinguishing agent heptafluoropropane(HFC227ea)
*GB 20031-2005 General technical specifications for foam fire extinguishing systems and components
*GB 25972-2010 Gas fire extinguishing systems and components
*GA 61-2010 General technical specifications of actuating and control devices of fixed extinguishing systems
*GA 834-2009 Foam-spray extinguishing equipments
GA 1288-2016 is referred in:
*JTBL1999-5 Rules of Automobile Freight Transportation -(Decree No.5 [1999] of the Ministry of Communications)
*YD/T 3168-2016 Radio frequency technical requirement and test method for public wireless LAN equipment
*LY/T 2721-2016 Standard for establishing characteristic values for mechanical properties of structural-use oriented strand board
*HDB/FZ100-2012
*HDB/FZ 104-2013 Made of cotton and chemical fiber belts, conveyor and processing trade consumption standards
*HDB/FZ070-2011 Standard for Unit Consumption in the Processing Trade of Men's Cotton and Chemical Fibre Knitted Vest
*HDB/FZ056-2009 Standard for Unit Consumption in the Processing Trade of Yarn-Dyed Woven Fabrics Made from Pure Mulberry Silk
*HDB/FZ055-2009 Standard for Unit Consumption in the Processing Trade of Cotton and Syntlhetic Fibre Weft Knitted Fabrics
*HDB/FZ054-2009 Standard for Unit Consumption in the Processing Trade of Linen and Cotton, Artificial Fibre Blended Yarn-Dyed Woven Fabrics (Grey Cloth)
*HDB/FZ053-2009 Standard for Unit Consumption in the Processing Trade of Blenched, Dyed and Printed Woven Fabrics Made from Linen and Cotton, Chemical Fibre Blends
*HDB/FZ052-2009 Standard for Unit Consumption in the Processing Trade of Nylon-6 Fabric Tapes
*HDB/FZ051-2009 Standard for Unit Consumption in the Processing Trade of Combed Wool and Chemical Fibre Blended Woven Fabrics
*HDB/FZ131-2016 Standard for Unit Consumption in the Processing Trade of Chinlon-6 Drawn Single Yarn
Code of China
Standard
GA 1288-2016  Heptafluoropropane foam fire extinguishing system (English Version)
Standard No.GA 1288-2016
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count14500 words
Price(USD)430.0
Implemented on2016-8-10
Deliveryvia email in 1 business day
Detail of GA 1288-2016
Standard No.
GA 1288-2016
English Name
Heptafluoropropane foam fire extinguishing system
Chinese Name
七氟丙烷泡沫灭火系统
Chinese Classification
C84
Professional Classification
GA
ICS Classification
Issued by
Ministry of Public Security
Issued on
2016-03-10
Implemented on
2016-8-10
Status
superseded
Superseded by
XF 1288-2016 Heptafluoropropane foam fire extinguishing system
Superseded on
2016-8-10
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
14500 words
Price(USD)
430.0
Keywords
GA 1288-2016, GA/T 1288-2016, GAT 1288-2016, GA1288-2016, GA 1288, GA1288, GA/T1288-2016, GA/T 1288, GA/T1288, GAT1288-2016, GAT 1288, GAT1288
Introduction of GA 1288-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. In this standard, Clauses 5 and 7 are compulsory, and others are voluntary. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the Fire Department of Ministry of Public Security. This standard is under the jurisdiction of SAC/TC 113/SC 2 Technical Subcommittee on Fixed Fire Extinguishing System of National Technical Committee on Fire Protection of Standardization Administration of China. This standard is issued for the first time. Introduction The issuing body of this document draws attention to the fact that claims of compliance with this document may involve the use of relevant patents (with the patent numbers of ZL 200810120340.2 and ZL 200820163235.2). The issuing body of this document takes no position concerning the evidence, validity and scope of this patent right. The patent holder has assured the issuing body of this document that he/she allows any organization or individual to apply the patents (with the patent numbers of ZL 200810120340.2 and ZL 200820163235.2) for free on the basis of reasonableness and nondiscrimination during implementing this professional standard. The patent holders’ statements have been put on records at the issuing body of this document. The relevant information may be obtained through the following contact information: Patentee: Hangzhou New Epoch Safety Products Co., Ltd. and Hangzhou New Epoch Fire Protection Science & Technology Co., Ltd. Address: No. 3, Tangning Road, Linping Development Zone, Yuhang District, Hangzhou, Zhejiang, 311100. Attention is drawn to the possibility that some other contents of this document may also be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. Heptafluoropropane foam fire extinguishing system 1 Scope This standard specifies the terms and definitions, classification and model, technical requirements, test methods, inspection rules as well as marking, packaging, transport and storage of heptafluoropropane foam fire extinguishing system and components. This standard is applicable to the heptafluoropropane foam fire extinguishing system and components. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3222.2 Acoustics - Description, measurement and assessment of environmental noise - Part 2: Determination of environmental noise levels GB/T 3797 Electrical control assemblies GB 4208 Degrees of protection provided by enclosure (IP Code) GB/T 9969 General principles for preparation of instructions for use of industrial products GB 15308 Foam extinguishing agent GB 18614 Fire extinguishing agent heptafluoropropane (HFC227ea) GB 20031-2005 General technical specifications for foam fire extinguishing systems and components GB 25972-2010 Gas fire extinguishing systems and components GA 61-2010 General technical specifications of actuating and control devices of fixed extinguishing systems GA 834-2009 Foam-spray extinguishing equipments 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 heptafluoropropane foam fire extinguishing system fire extinguishing system which is composed of water supply system, foam concentrate storage tank, foam proportioning device, heptafluoropropane feeding device, heptafluoropropane proportioning device, heptafluoropropane foam maker, control cabinet, valve, pipeline, etc. and is able to generate heptafluoropropane foam 3.2 heptafluoropropane concentration volume percentage of liquid heptafluoropropane in heptafluoropropane foam mixture 3.3 heptafluoropropane proportioning device device for mixing liquid heptafluoropropane and foam mixture at a specified concentration 3.4 storage pressure equilibrium pressure in the heptafluoropropane storage container at 20℃ after it is filled with heptafluoropropane at the maximum filling density and pressurized 3.5 heptafluoropropane foam maker device for foaming and producing heptafluoropropane foam by gasification of liquid heptafluoropropane in heptafluoropropane foam mixture 3.6 maximum working pressure of system maximum working pressure of heptafluoropropane proportioning device 4 Classification and model 4.1 Classification 4.1.1 The heptafluoropropane foam fire extinguishing system may be classified by the type of foam proportioning device into: a) balanced type, with code of P; b) metering injection type, with code of J; c) pressure type, with code of Y; d) mechanical pumping type, with code of B; e) other types, with code of Q. 4.1.2 The heptafluoropropane foam fire extinguishing system may be classified by heptafluoropropane storage type into: a) external stored pressure type, with code of W; b) internal stored pressure type, not marked. 4.2 Model 4.2.1 System model The system shall be modeled following the following requirements: Example: PQF-WP/200/6/1.6 refers to external stored pressure heptafluoropropane foam fire extinguishing system with a maximum working pressure of 1.6 MPa, a foam concentration of 6%, a maximum flow of 200 L/s and a balanced foam proportioning device. 4.2.2 Component model See Annex A for the preparation method of component model. 5 Technical requirements 5.1 System 5.1.1 Main performance parameters See Table 1 for the main performance parameters of heptafluoropropane foam fire extinguishing system (hereinafter referred to as system). Table 1 Main performance parameters of system System working pressure range MPa System flow range L/s Heptafluoropropane concentration Foam concentrate concentration Continuous working time min Value published by the manufacturer Value published by the manufacturer 5% 3% and 6% ≥15 5.1.2 System composition 5.1.2.1 The system shall at least consist of foam concentrate storage tank, foam proportioning device, heptafluoropropane feeding device, heptafluoropropane proportioning device, heptafluoropropane foam maker, control cabinet, valve, pipeline, etc. 5.1.2.2 All components of the system shall be firmly fixed, reliably connected, installed at the correct position, reasonably arranged in an integrated way, and convenient for operation, inspection and maintenance. 5.1.3 Appearance All components of the system shall be free from any obvious processing defects or mechanical damages, and their external surfaces shall be subject to anti-corrosion treatment, and the anti-corrosion coating and plating shall be complete and even. 5.1.4 Marking 5.1.4.1 The name and filling pressure of the gas shall be marked on the front surface of the gas cylinder group, and the handwriting shall be clear and legible. 5.1.4.2 Each manually operated part of the system shall be marked with the operation method via texts and graphic symbols, and the proportioning device, check valve, etc. shall be marked with the medium flow direction. 5.1.4.3 The system shall be provided with permanent signs at conspicuous position, with the content at least covering product name, model and specification, number of standard executed, type of applicable foam concentrate, service temperature range, working pressure range of system, flow range of system, storage pressure of heptafluoropropane storage device, manufacturer, product number, date of manufacture, etc. The signs shall remain legible after being subjected to the salt spray corrosion test according to 6.11. 5.1.5 Start-up operation requirements 5.1.5.1 Start method The system shall be provided with automatic start, manual start and mechanical emergency start functions. For manual start and mechanical emergency start, effective measures shall be taken to prevent misoperation. 5.1.5.2 Delayed start function The automatic start of the system shall be provided with delayed start function. The delay time may be continuously adjustable from 0s to 30s; if step adjustment is adopted, the interval shall not be more than 10s. The delay time measurement error shall not be more than 20% of the set time. 5.1.5.3 Start-up operation The system shall be started in different ways, and its action shall be accurate, reliable and fault-free. 5.1.6 Fire extinguishing requirements Systems using alcohol-resistant foam concentrate shall be subjected to the test for extinguishing propylene oxide and n-pentane oil pan fire; systems using other types of foam concentrates shall be subjected to the test for extinguishing n-pentane oil pan fire. The fire extinguishing test shall be performed in accordance with 6.12, and the results shall meet the following requirements: a) the sprayed foam layer shall completely cover the fuel surface; b) the flame shall be completely extinguished by the end of the spray of the fire-extinguishing foam; c) after the fire is extinguished, the fuel covered by foam shall be free from reignition, burning or flashover; d) after the fire is extinguished, there shall be remaining fuel in the oil pan. 5.2 Foam extinguishing agent and heptafluoropropane extinguishing agent The foam extinguishing agent shall meet the requirements of GB 15308 and the heptafluoropropane extinguishing agent shall meet the requirements of GB 18614. 5.3 Foam proportioning device and foam concentrate storage tank 5.3.1 Foam proportioning device The foam proportioning device shall meet the requirements in 5.1 of GB 20031-2005. 5.3.2 Foam concentrate storage tank The foam concentrate storage tank shall meet the requirements in 5.1.2.3 or 5.3.7 of GB 20031-2005. 5.4 Heptafluoropropane proportioning device 5.4.1 Marking Permanent signs shall be provided at a prominent position on the enclosure of the heptafluoropropane proportioning device, with the flow direction of medium indicated by arrows. The sign shall at least indicate the following information: product name, specification and model, product number, working pressure range, flow range, heptafluoropropane concentration, executive standard, name or trademark of the manufacturer, etc. The signs shall remain legible after being subjected to the salt spray corrosion test according to 6.11. 5.4.2 Materials Parts and components that are in direct contact with the mixture of heptafluoropropane and foam shall be made of materials with a corrosion resistance not inferior to that of copper alloys. 5.4.3 Main performance parameters The main performance parameters of heptafluoropropane proportioning device shall meet the requirements in Table 2.   Table 2 Main performance parameters of heptafluoropropane proportioning device Inlet working pressure range MPa Flow range L/s Concentration Pressure loss MPa Value published by the manufacturer Value published by the manufacturer 5%~6% ≤0.2 5.4.4 Strength and sealing 5.4.4.1 Strength Carry out the strength test according to 6.2, during which the test pressure shall be 1.5 times the maximum working pressure and maintained for 5 min. After the test, there shall be no leakage, structural damage, permanent deformation or rupture of any component of the heptafluoropropane proportioning device. 5.4.4.2 Sealing Carry out the seal test according to 6.3, during which the test pressure shall be 1.1 times the maximum working pressure and maintained for 5 min. After the test, there shall be no leakage, deformation or damage of any component of the heptafluoropropane proportioning device.
Contents of GA 1288-2016
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and model 5 Technical requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transport and storage Annex A (Normative) Method for preparation of component model Annex B (Normative) Test procedures and sample quantity for the system Annex C (Normative) Test procedures and sample quantity for heptafluoropropane proportioning device Annex D (Normative) Test procedures and sample quantity for heptafluoropropane foam maker Annex E (Normative) Test procedures and sample quantity for heptafluoropropane storage device Annex F (Normative) Test procedures and sample quantity for heptafluoropropane control valve Annex G (Normative) Test procedures and sample quantity for control cabinet
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GA 1288-2016, GA/T 1288-2016, GAT 1288-2016, GA1288-2016, GA 1288, GA1288, GA/T1288-2016, GA/T 1288, GA/T1288, GAT1288-2016, GAT 1288, GAT1288