2025-7-15 18.97.14.89
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 22134-2008
GB 22134-2008   Compatibility Requirements of Automatic Fire Alarm System Components (English Version)
Standard No.: GB 22134-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4000 words Price(USD):100.0 remind me the price change

Email:

Implemented on:2010-2-1 Delivery: via email in 1 business day
,,
Standard No.: GB 22134-2008
English Name: Compatibility Requirements of Automatic Fire Alarm System Components
Chinese Name: 火灾自动报警系统组件兼容性要求
Chinese Classification: C81    Fire monitoring, alarming and fire-fighting dispatching system
Professional Classification: GB    National Standard
ICS Classification: 13.220.20 13.220.20    Fire protection 13.220.20
Issued by: AQSIQ; SAC
Issued on: 30-Dec-08
Implemented on: 2010-2-1
Status: valid
Language: English
File Format: PDF
Word Count: 4000 words
Price(USD): 100.0
Delivery: via email in 1 business day
1 Scope This standard specifies the requirements for compatibility and connectability of automatic fire alarm system components. This standard is applicable to the compatibility and connectability assessment of automatic fire alarm system components. 2 Normative References The provisions of the following standards, through reference into this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to this standard are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this standard. GB 4717 "Fire Alarm Control Units" GB 14287.1 "Alarm System for Electric Fire Prevention-Part 1: Alarm Control Units for Electric Fire Prevention" GB 16806 "Automatic Control System for Fire Protection" GB 16808 "Combustible Gas Alarm Control Units" 3 Terms and Definitions The following terms and definitions apply in this standard. 3.1 Component type 1 The device required having the function of protecting the life and property safety in accordance with the national standards or codes. 3.2 Component type 2 The device not required having the function of protecting the life and property safety in accordance with the national standards or codes. 3.3 Compatibility The ability for the components type 1 to work by connection. 3.4 Connectability The ability for the component type 2 and component type 1 to work by connection. 4 General Requirements 4.1 General The compatibility and connectability of the automatic fire alarm system (the system functions are detailed in Appendix A) components shall firstly meet the requirements of this chapter, and then shall be tested according to the requirements of Chapter 5 and shall meet the test requirements. Moreover, the automatic fire alarm system components shall be carried out with the compatibility and connectability assessment according to the requirements of Chapter 6 and shall meet the test requirements of assessment. 4.2 Compatibility requirement 4.2.1 The component classification of the automatic fire alarm system and connecting device (or parts) shall comply with those specified in Appendix B, components type 1 shall adopt the product certificated by the fire product quality supervision and inspection organization of the State. The operation of components type 2 shall not affect the normal operations of automatic fire alarm system. 4.2.2 The connected automatic fire alarm system components, such as independent (zone) fire alarm control units, combustible gas alarm control units, alarm control units for electric fire prevention and fire detectors, manual fire trigger device, combustible gas detectors, detectors for electric fire prevention and fire alarm devices, shall meet the following requirements respectively:
Contents Foreword II 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 5 Requirements and Test Methods 6 Assessment Method Appendix A (Normative) Functions of Automatic Fire Alarm System Appendix B (Normative) Component Classification of Automatic Fire Alarm System Appendix C (Normative) Theoretical Analysis Method
Referred in GB 22134-2008:
*GB 4717-2005 Fire alarm control units
*GB 14287.1-2014 Electrical Fire Monitoring System - Part 1: Electrical Fire Monitoring Equipment
*GB 16806-2006/XG1-2016 Automatic control system for fire protection
*GB 16808-2008 Combustible gas alarm control units
GB 22134-2008 is referred in:
* GB 50116-2013 Code for design of automatic fire alarm system
* GB 50116-2013 Code for design of automatic fire alarm system
*GB 51309-2018 Technical standard for fire emergency lighting and evacuate indicating system
*GB 51428-2021 Standard for fire protection design of coal chemical engineering
*GB 17945-2024 Fire emergency lighting and evacuate indicating system
Code of China
Standard
GB 22134-2008  Compatibility Requirements of Automatic Fire Alarm System Components (English Version)
Standard No.GB 22134-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2010-2-1
Deliveryvia email in 1 business day
Detail of GB 22134-2008
Standard No.
GB 22134-2008
English Name
Compatibility Requirements of Automatic Fire Alarm System Components
Chinese Name
火灾自动报警系统组件兼容性要求
Chinese Classification
C81
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
30-Dec-08
Implemented on
2010-2-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
GB 22134-2008, GB/T 22134-2008, GBT 22134-2008, GB22134-2008, GB 22134, GB22134, GB/T22134-2008, GB/T 22134, GB/T22134, GBT22134-2008, GBT 22134, GBT22134
Introduction of GB 22134-2008
1 Scope This standard specifies the requirements for compatibility and connectability of automatic fire alarm system components. This standard is applicable to the compatibility and connectability assessment of automatic fire alarm system components. 2 Normative References The provisions of the following standards, through reference into this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to this standard are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this standard. GB 4717 "Fire Alarm Control Units" GB 14287.1 "Alarm System for Electric Fire Prevention-Part 1: Alarm Control Units for Electric Fire Prevention" GB 16806 "Automatic Control System for Fire Protection" GB 16808 "Combustible Gas Alarm Control Units" 3 Terms and Definitions The following terms and definitions apply in this standard. 3.1 Component type 1 The device required having the function of protecting the life and property safety in accordance with the national standards or codes. 3.2 Component type 2 The device not required having the function of protecting the life and property safety in accordance with the national standards or codes. 3.3 Compatibility The ability for the components type 1 to work by connection. 3.4 Connectability The ability for the component type 2 and component type 1 to work by connection. 4 General Requirements 4.1 General The compatibility and connectability of the automatic fire alarm system (the system functions are detailed in Appendix A) components shall firstly meet the requirements of this chapter, and then shall be tested according to the requirements of Chapter 5 and shall meet the test requirements. Moreover, the automatic fire alarm system components shall be carried out with the compatibility and connectability assessment according to the requirements of Chapter 6 and shall meet the test requirements of assessment. 4.2 Compatibility requirement 4.2.1 The component classification of the automatic fire alarm system and connecting device (or parts) shall comply with those specified in Appendix B, components type 1 shall adopt the product certificated by the fire product quality supervision and inspection organization of the State. The operation of components type 2 shall not affect the normal operations of automatic fire alarm system. 4.2.2 The connected automatic fire alarm system components, such as independent (zone) fire alarm control units, combustible gas alarm control units, alarm control units for electric fire prevention and fire detectors, manual fire trigger device, combustible gas detectors, detectors for electric fire prevention and fire alarm devices, shall meet the following requirements respectively:
Contents of GB 22134-2008
Contents Foreword II 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 5 Requirements and Test Methods 6 Assessment Method Appendix A (Normative) Functions of Automatic Fire Alarm System Appendix B (Normative) Component Classification of Automatic Fire Alarm System Appendix C (Normative) Theoretical Analysis Method
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB 22134-2008, GB/T 22134-2008, GBT 22134-2008, GB22134-2008, GB 22134, GB22134, GB/T22134-2008, GB/T 22134, GB/T22134, GBT22134-2008, GBT 22134, GBT22134