2023-2-9 3.237.29.69
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 25034-2010
GB 25034-2010   Gas-fired heating and hot water combi-boilers (English Version)
Standard No.: GB 25034-2010 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 32000 words Price(USD):280.0 remind me the price change

Email:

Implemented on:2011-7-1 Delivery: via email in 1 business day
,,
Standard No.: GB 25034-2010
English Name: Gas-fired heating and hot water combi-boilers
Chinese Name: 燃气采暖热水炉
Chinese Classification: P46    Heat supply and heating engineering
Professional Classification: GB    National Standard
ICS Classification: 91.140.99 91.140.99    Other installations in buildings 91.140.99
Issued by: AQSIQ, SAC
Issued on: 2010-9-2
Implemented on: 2011-7-1
Status: superseded
Superseded by:GB 25034-2020 Gas-fired heating and hot water combi-boiler
Superseded on:2021-11-1
Language: English
File Format: PDF
Word Count: 32000 words
Price(USD): 280.0
Delivery: via email in 1 business day
This standard specifies the terms and definitions, classification and parameter, material, construction and safety requirements, operational requirements, test methods, inspection rules, marking, cautions and instructions, packing, transport and storage of gas-fired heating and hot water combi-boilers of closed combustion (hereinafter referred to as "boiler"). This standard is applicable to the combination boilers for heating and hot water, with nominal heat input not exceeding 70kW, maximum heating operating water pressure not exceeding 0.3MPa, operating water temperature not greater than 95℃, adopting atmospheric burner or fan assisted burner or full premix burner, also to single heating boilers. This standard is not applicable to the following boilers: ——Natural draught flue type and outdoor boilers; ——Condensing boilers; ——Volumetric boilers; ——Boilers adopting two sets of independent combustion systems respectively for heating and hot water in the same enclosure, including the boilers with common duct.
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Parameters 5 Material, Construction and Safety Requirements 6 Operational Requirements 7 Test Methods 8 Inspection Rules 9 Marking, Cautions and Instructions 10 Packing, Transport and Storage Appendix A (Informative) Chapter and Article Numbers of This Standard which are Corresponding to That of EN 483: 1999 and EN 625: 1996 Appendix B (Informative) Technical Differences and Causes between this Standard and EN 483: 1999 and EN 625: 1996 Appendix C (Informative) Classification by Air Supply and Evacuation Installation Modes Appendix D (Informative) Requirements of Composition and Sealing Force of Gas Automatic Stop Valve in Gas System Appendix E (Informative) NOx Pollution Appendix F (Normative) Electrical Safety of the Boilers Using AC Power Supply Appendix G (Normative) Electromagnetic Compatibility Safety Appendix H (Informative) Heat Losses from Test Rig of the Indirect Method and Test Method for Contributions of Circulating Pump Appendix I (Informative) Means of Determining the Ignition Time at Full Load Bibliography
Referred in GB 25034-2010:
* GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
* GB/T 1019-2008 General requirements for the package of household and similar electrical appliances
* GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
* GB/T 2828.2-2008 Sampling procedures for inspection by attributes - Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
* GB 4208-2008 Degrees of Protection Provided By Enclosure (IP Code)
* GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
* GB/T 5013.1-2008 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts
* GB 5023.1-1997
* GB/T 7306.1-2000 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads--Part 1:Parallel internal and taper external threads
* GB/T 7306.2-2000 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads--Part 2: Taper internal and external threads
* GB/T 7307-2001 Pipe threads with 55 degree thread angle where pressure-tight joints are not made on the threads
* GB/T 12113-2003 Methods of measurement of touch current and protective conductor current
* GB/T 13611-2006 Classification and essential property of city gas
* GB 14536.1-2008 Automatic electrical controls for household and similar use - Part 1: General requirements
* GB 14536.6-2008 Automatic electrical controls for household and similar use - Particular requirements for automatic electrical burner control systems
* GB 14536.10-2008 electrical controls for household and similar use - Particular requirements for temperature sensing controls
* GB/T 16411-2008 Universal test methods of gas burning appliances for domestic use
* GB/T 17624.1-1998 Electromagnetic compatibility - General - Application and interpretation of fundamental definitions and terms
* GB/T 17626.1-2006 Electromagnetic compatibility - Testing and measurement techniques - Overview of immunity tests
* GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
* GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
* GB/T 17626.11-2008 Electromagnetic compatibility - Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
* GB/T 17627.1-1998 High-voltage test techniques for low-voltage equipment Part 1: Definitions, test and procedure requirements
* GB/T 17799.1-1999 Electromagnetic compatibility - Generic Standards - Immunity for residential, commercial and light-industrial environments
* CJ/T 3074-1998 Electronic controller of household gas burning appliances
GB 25034-2010 is referred in:
* CJ/T 395-2012 Gas-fired heating and hot water condensing combi-boilers
* CJ/T 395-2012 Gas-fired heating and hot water condensing combi-boilers
* GB 20665-2015 Minimum allowable values of energy efficiency and energy efficiency grades for domestic gas instantaneous water heaters and gas fired heating and hot water combi-boilers
*GB 35848-2018 Commercial gas-burning appliance
Code of China
Standard
GB 25034-2010  Gas-fired heating and hot water combi-boilers (English Version)
Standard No.GB 25034-2010
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count32000 words
Price(USD)280.0
Implemented on2011-7-1
Deliveryvia email in 1 business day
Detail of GB 25034-2010
Standard No.
GB 25034-2010
English Name
Gas-fired heating and hot water combi-boilers
Chinese Name
燃气采暖热水炉
Chinese Classification
P46
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2010-9-2
Implemented on
2011-7-1
Status
superseded
Superseded by
GB 25034-2020 Gas-fired heating and hot water combi-boiler
Superseded on
2021-11-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
32000 words
Price(USD)
280.0
Keywords
GB 25034-2010, GB/T 25034-2010, GBT 25034-2010, GB25034-2010, GB 25034, GB25034, GB/T25034-2010, GB/T 25034, GB/T25034, GBT25034-2010, GBT 25034, GBT25034
Introduction of GB 25034-2010
This standard specifies the terms and definitions, classification and parameter, material, construction and safety requirements, operational requirements, test methods, inspection rules, marking, cautions and instructions, packing, transport and storage of gas-fired heating and hot water combi-boilers of closed combustion (hereinafter referred to as "boiler"). This standard is applicable to the combination boilers for heating and hot water, with nominal heat input not exceeding 70kW, maximum heating operating water pressure not exceeding 0.3MPa, operating water temperature not greater than 95℃, adopting atmospheric burner or fan assisted burner or full premix burner, also to single heating boilers. This standard is not applicable to the following boilers: ——Natural draught flue type and outdoor boilers; ——Condensing boilers; ——Volumetric boilers; ——Boilers adopting two sets of independent combustion systems respectively for heating and hot water in the same enclosure, including the boilers with common duct.
Contents of GB 25034-2010
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Parameters 5 Material, Construction and Safety Requirements 6 Operational Requirements 7 Test Methods 8 Inspection Rules 9 Marking, Cautions and Instructions 10 Packing, Transport and Storage Appendix A (Informative) Chapter and Article Numbers of This Standard which are Corresponding to That of EN 483: 1999 and EN 625: 1996 Appendix B (Informative) Technical Differences and Causes between this Standard and EN 483: 1999 and EN 625: 1996 Appendix C (Informative) Classification by Air Supply and Evacuation Installation Modes Appendix D (Informative) Requirements of Composition and Sealing Force of Gas Automatic Stop Valve in Gas System Appendix E (Informative) NOx Pollution Appendix F (Normative) Electrical Safety of the Boilers Using AC Power Supply Appendix G (Normative) Electromagnetic Compatibility Safety Appendix H (Informative) Heat Losses from Test Rig of the Indirect Method and Test Method for Contributions of Circulating Pump Appendix I (Informative) Means of Determining the Ignition Time at Full Load Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 25034-2010, GB/T 25034-2010, GBT 25034-2010, GB25034-2010, GB 25034, GB25034, GB/T25034-2010, GB/T 25034, GB/T25034, GBT25034-2010, GBT 25034, GBT25034