2023-3-22 3.238.253.163
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 6819-2004
GB 6819-2004   Dissolved acetylene (English Version)
Standard No.: GB 6819-2004 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4000 words Price(USD):80.0 remind me the price change

Email:

Implemented on:2005-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB 6819-2004
English Name: Dissolved acetylene
Chinese Name: 溶解乙炔
Chinese Classification: G16    Basic organic chemicals
Professional Classification: GB    National Standard
ICS Classification: 71.080.10 71.080.10    Aliphatic hydrocarbons 71.080.10
Issued by: AQSIQ and SAC
Issued on: 2004-11-29
Implemented on: 2005-5-1
Status: valid
Superseding:GB 6819-1996 Dissolved acetylene
Language: English
File Format: PDF
Word Count: 4000 words
Price(USD): 80.0
Delivery: via email in 1 business day
Warning— this standard hasn't point out any potential safety problems. The users are under the obligation to adopt proper safety and health measures and shall ensure the dissolved acetylene to meet the requirements specified in national relevant regulations. 1 Scope This standard specifies the requirements, test methods, inspection rules, marks, labels, packages (filling), transportation, storage and safety etc. of dissolved acetylene. This standard is applicable to the coarse acetylene gas produced by calcium carbide and water action or with natural gas pyrolysis method after it is purified, compressed, dried and ten dissolved into acetone and then stored in the cylinder fully filled with porous aggregate. This product is mainly used as the fuel gas for metal welding, metal cutting and heating. Molecular formula: C2H2 Relative molecular mass: 26.04 (according to international relative atomic mass in 2001) 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard. GB/T1250 Rules for Expression and Judgement of Limiting Values GB/T6682 Water for Laboratory Use-Specifications [GB/T 6682-1992, neq IS0 3696: 1987] GB 7144 Colored Cylinder Mark for Gases GB 11638 Dissolved Acetylene Cylinders GB 13591-1992 Rules for the Filling of Dissolved Acetylene GB 16804 Precautionary Labels for Gas Cylinders Laoguozi (1993) No. 4 "Specification on Safety Supervision of Dissolved Acetylene Cylinders" by Formerly Ministry of Labor of the People's Republic of China 3 Requirements 3.1 Dissolved acetylene quality shall meet the technical requirements specified in Table 1. Table 1: Technical Requirements Item Index Acetylene volume fraction/% ≥ 98.0 Phosphine and sulfur hydride tests Silver-nitrate test paper doesn't discolor 4 Test Methods Unless otherwise specified, during analysis, only confirmed analytical reagent and Grade 3 water which meet the requirements stated in GB/T 6682 are used. 4.1 Sample preparation Cylinder being filled with acetylene gas and after 8h stillness is taken; before sampling, 5% mass of filled acetylene gas is let out; while in those areas where temperature is greater than 28℃, the let out mass of acetylene gas may be properly added but the most shall not be greater than 5% mass of filled acetylene. 4.2 Acetylene purity measuring Either bromine method or fuming sulfuric acid method, of which bromine method is the arbitration one 4.2.1 Bromine method 4.2.1.1 Method summary Acetylene is absorbed by the bromine saturated solution of potassium bromide and then generate chemical reaction after which tetrabromoethane is generated. Then acetylene purity is measured according to the volume after bromine saturated solution absorbing. 4.2.1.2 Reagent 4.2.1.2.1 Bromine; 4.2.1.2.2 Potassium bromide solution: 300g/L 4.2.1.2.3 Bromine saturated solution (absorption solution) of potassium bromide: proper amount of potassium bromide solution is taken and put into a ground glass stoppered flask with plug; then bromine is added slowly during which the flask is shaken so as to make the solution to be saturated; then the solution is stilled for one day for standby usage. When the absorbency of absorption solution is poor, the solution must be prepared again.
Foreword I 1 Scope 2 Normative References 3 Requirements 4 Test Methods 5 Inspection Rules 6 Package (filling), Mark, Label, Transportation and Storage 7 Safety Annex A (Informative) Comparison between the Chapter and Article Numbers of This Standard and Those of JIS K 1902: 1980 (Confirmed in 1992) Annex B (Informative) Technical Differences and the Corresponding Reasons between This Standard and JIS K 1902: 1980 (Confirmed in 1992)
Referred in GB 6819-2004:
*GB/T 1250-1989
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB 7144-1999 Coloured cylinder mark for gases
*GB 11638-2011 Dissolved acetylene cylinders
*GB 13591-1992 Rules for the filling of dissolved acetylene
*GB 16804-2011 Precautionary labels for gas cylinders
GB 6819-2004 is referred in:
* DL/T 869-2012 The code of Welding for Power Plant
* GB 50236-2011 Code for Construction of Field Equipment, Industrial Pipe Welding Engineering
* JGJ 18-2012 Specification for welding amd aceptance of reinforcing steel bars
* GB 50755-2012 Code for Construction of Steel Structures
* JGJ 18-2012 Specification for welding amd aceptance of reinforcing steel bars
* GB 50755-2012 Code for Construction of Steel Structures
* DL/T 869-2012 The code of Welding for Power Plant
* GB 50236-2011 Code for Construction of Field Equipment, Industrial Pipe Welding Engineering
* GB/T 13080-2004 Determination of lead in feeds—Method using atomic absorption spectrometry
* DL/T 5017-2007 Specification for Manufacture Installation and Acceptance of Steel Penstocks in Hydroelectric and Hydraulic Engineering
* DL/T 5017-2007 Specification for Manufacture Installation and Acceptance of Steel Penstocks in Hydroelectric and Hydraulic Engineering
* GB 11638-2011 Dissolved acetylene cylinders
*QB/T 2968-2008 Determination of strontium chloridein in toothpastes
*QB/T 2966-2014 Functional Toothpastes
*JB/T 8856-2018 Dissolved acetylene systems
*GB/T 13080-2018 Determination of lead in feeds—Atomic absorption spectrometry
*GB/T 13082-2021 Determination of cadmium in feeds
Code of China
Standard
GB 6819-2004   Dissolved acetylene (English Version)
Standard No.GB 6819-2004
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)80.0
Implemented on2005-5-1
Deliveryvia email in 1 business day
Detail of GB 6819-2004
Standard No.
GB 6819-2004
English Name
Dissolved acetylene
Chinese Name
溶解乙炔
Chinese Classification
G16
Professional Classification
GB
ICS Classification
Issued by
AQSIQ and SAC
Issued on
2004-11-29
Implemented on
2005-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 6819-1996 Dissolved acetylene
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Keywords
GB 6819-2004, GB/T 6819-2004, GBT 6819-2004, GB6819-2004, GB 6819, GB6819, GB/T6819-2004, GB/T 6819, GB/T6819, GBT6819-2004, GBT 6819, GBT6819
Introduction of GB 6819-2004
Warning— this standard hasn't point out any potential safety problems. The users are under the obligation to adopt proper safety and health measures and shall ensure the dissolved acetylene to meet the requirements specified in national relevant regulations. 1 Scope This standard specifies the requirements, test methods, inspection rules, marks, labels, packages (filling), transportation, storage and safety etc. of dissolved acetylene. This standard is applicable to the coarse acetylene gas produced by calcium carbide and water action or with natural gas pyrolysis method after it is purified, compressed, dried and ten dissolved into acetone and then stored in the cylinder fully filled with porous aggregate. This product is mainly used as the fuel gas for metal welding, metal cutting and heating. Molecular formula: C2H2 Relative molecular mass: 26.04 (according to international relative atomic mass in 2001) 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard. GB/T1250 Rules for Expression and Judgement of Limiting Values GB/T6682 Water for Laboratory Use-Specifications [GB/T 6682-1992, neq IS0 3696: 1987] GB 7144 Colored Cylinder Mark for Gases GB 11638 Dissolved Acetylene Cylinders GB 13591-1992 Rules for the Filling of Dissolved Acetylene GB 16804 Precautionary Labels for Gas Cylinders Laoguozi (1993) No. 4 "Specification on Safety Supervision of Dissolved Acetylene Cylinders" by Formerly Ministry of Labor of the People's Republic of China 3 Requirements 3.1 Dissolved acetylene quality shall meet the technical requirements specified in Table 1. Table 1: Technical Requirements Item Index Acetylene volume fraction/% ≥ 98.0 Phosphine and sulfur hydride tests Silver-nitrate test paper doesn't discolor 4 Test Methods Unless otherwise specified, during analysis, only confirmed analytical reagent and Grade 3 water which meet the requirements stated in GB/T 6682 are used. 4.1 Sample preparation Cylinder being filled with acetylene gas and after 8h stillness is taken; before sampling, 5% mass of filled acetylene gas is let out; while in those areas where temperature is greater than 28℃, the let out mass of acetylene gas may be properly added but the most shall not be greater than 5% mass of filled acetylene. 4.2 Acetylene purity measuring Either bromine method or fuming sulfuric acid method, of which bromine method is the arbitration one 4.2.1 Bromine method 4.2.1.1 Method summary Acetylene is absorbed by the bromine saturated solution of potassium bromide and then generate chemical reaction after which tetrabromoethane is generated. Then acetylene purity is measured according to the volume after bromine saturated solution absorbing. 4.2.1.2 Reagent 4.2.1.2.1 Bromine; 4.2.1.2.2 Potassium bromide solution: 300g/L 4.2.1.2.3 Bromine saturated solution (absorption solution) of potassium bromide: proper amount of potassium bromide solution is taken and put into a ground glass stoppered flask with plug; then bromine is added slowly during which the flask is shaken so as to make the solution to be saturated; then the solution is stilled for one day for standby usage. When the absorbency of absorption solution is poor, the solution must be prepared again.
Contents of GB 6819-2004
Foreword I 1 Scope 2 Normative References 3 Requirements 4 Test Methods 5 Inspection Rules 6 Package (filling), Mark, Label, Transportation and Storage 7 Safety Annex A (Informative) Comparison between the Chapter and Article Numbers of This Standard and Those of JIS K 1902: 1980 (Confirmed in 1992) Annex B (Informative) Technical Differences and the Corresponding Reasons between This Standard and JIS K 1902: 1980 (Confirmed in 1992)
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 6819-2004, GB/T 6819-2004, GBT 6819-2004, GB6819-2004, GB 6819, GB6819, GB/T6819-2004, GB/T 6819, GB/T6819, GBT6819-2004, GBT 6819, GBT6819