2025-6-15 18.97.14.88
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 31433-2015
GB/T 31433-2015   General specification for building curtain walls,windows and doors (English Version)
Standard No.: GB/T 31433-2015 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 8500 words Price(USD):240.0 remind me the price change

Email:

Implemented on:2015-12-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 31433-2015
English Name: General specification for building curtain walls,windows and doors
Chinese Name: 建筑幕墙、门窗通用技术条件
Chinese Classification: P32    Building construction and decoration engineering
Professional Classification: GB    National Standard
Issued by: AQSIQ; SAC
Issued on: 2015-04-22
Implemented on: 2015-12-1
Status: valid
Language: English
File Format: PDF
Word Count: 8500 words
Price(USD): 240.0
Delivery: via email in 1 business day
General specifications for building curtain walls, windows and doors 1. Scope This standard specifies performance classification and selection, requirements and tests concerning curtain walls, windows and doors. This standard is applicable to civilian use curtain walls, windows and doors. This standard is either applicable to external wall decoration system with the panel directly affixed to the main structure or external wall hanging system without supporting frame or structure, nor applicable to special use doors and windows e.g., fire-proof windows and doors, escape windows and doors, smoke exhaust windows, ray shielding windows and doors, etc. 2. Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2680 Determination of light transmittance, solar direction transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors GB/T 5823 Terminology for building windows and doors GB/T 71 06 Graduations and test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors GB/T 8484 Graduation and test method for thermal insulating properties of doors and windows GB/T 8485 Graduation and test method for airborne sound insulating properties of windows and doors GB/T 91 58 Mechanical test methods for windows GB/T 11 976 Graduation and test method of day-lighting properties for external windows GB/T 1 251 3 Fire resistance tests --- Elements of building construction – Glazed elements GB/T 1 41 55 Doorsets --- Soft heavy body impact test GB/T 1 5227 Test method of air permeability, water tightness, wind load resistance performance for curtain walls GB/T 1 5763.1 Safety glazing materials in building --- Part 1 : Fire-resistant glass GB/T 1 5763.4 Safety glazing materials in building --- Part 4: Heat soaked thermally tempered glass GB/T 1 6776 Structural silicone sealants for building GB/T 1 8091 Optical properties of glass curtain walls GB/T 1 8250 Graduations and test method for performance of deformation between stories of curtain wall GB/T 21 086 Curtain wall for building GB/T 29043 Graduation and test method for thermal insulating properties of curtain walls GB/T 29049 Doorsets - Vertical load test GB/T 29530 Hinged or pivoted doors --- Determination of the resistance to static torsion GB/T 29737 Graduations and test method of sand and dust resistance performance for building external windows and doors GB/T 29738 Graduations and test method for performance of exterior windows and doors, curtain walls impacted by windborne debris in windstorm GB/T 29739 Test method of resistance to repeat opening and closing for windows and doors GB/T 29908 Classification and test method of air-blast resistance performance for curtain walls, windows and doors GB/T 30591 Requirements for size coordination for opening of windows and doors in building GB 5001 6 Code of design on building fire protection and prevention GB 50057 Building Lightning Protection Design Code JG/T 397 Method of thermal recycling test for building curtain wall JGJ 1 02 Technical code for glass curtain wall engineering JGJ/T 1 51 Calculation specification for thermal performance of windows, doors and glass curtain walls ISO 1 5822 Test method of doorset opening performance in diagonal deformation ---Seismic aspects 3. Terms and definitions For the purpose of this standard, the terms and definitions given in GB/T 5823 and GB/T 21 086 and the following terms and definitions apply. 3.1 similar design The characteristics that the change in the designs of curtain walls, windows and doors, glasses and hardware etc. or the design of assembly manner not triggering the change of performance 3.2 representative sample The test piece which can represent the results of performance tests of similar design curtain walls, windows or glasses 3.3 fire resistant integrity of windows and doors The capacity of stopping fire flame or hot air passing through or fire flame appearing at the back of fire when one side of building windows and doors get fire under the standard fire resistant test condition 4. Performance classification and selection
GB/T 31433-2015 is referred in:
*GB/T 7106-2019 Test methods of air permeability,watertightness,wind load resistance performance for building external windows and doors
*GB/T 8478-2020 Aluminium windows and doors
*GB/T 38252-2019 Test method of fire-resistant integrity for building windows and doors
*GB/T 41659-2022 General technical requirements for medical doors of building
*GB/T 41334-2022 Technical specifications for accessbility of windows and doors
*GB/T 43496-2023 Test method of thermal cycling and condensation resistance of curtain walls
*GB/T 29043-2023 Test method for thermal insulating performance of curtain walls
*GB/T 28886-2023 Plastic windows and doors for buildings
*GB 16809-2024 Fire resistant windows
Code of China
Standard
GB/T 31433-2015  General specification for building curtain walls,windows and doors (English Version)
Standard No.GB/T 31433-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)240.0
Implemented on2015-12-1
Deliveryvia email in 1 business day
Detail of GB/T 31433-2015
Standard No.
GB/T 31433-2015
English Name
General specification for building curtain walls,windows and doors
Chinese Name
建筑幕墙、门窗通用技术条件
Chinese Classification
P32
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2015-04-22
Implemented on
2015-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
240.0
Keywords
GB/T 31433-2015, GB 31433-2015, GBT 31433-2015, GB/T31433-2015, GB/T 31433, GB/T31433, GB31433-2015, GB 31433, GB31433, GBT31433-2015, GBT 31433, GBT31433
Introduction of GB/T 31433-2015
General specifications for building curtain walls, windows and doors 1. Scope This standard specifies performance classification and selection, requirements and tests concerning curtain walls, windows and doors. This standard is applicable to civilian use curtain walls, windows and doors. This standard is either applicable to external wall decoration system with the panel directly affixed to the main structure or external wall hanging system without supporting frame or structure, nor applicable to special use doors and windows e.g., fire-proof windows and doors, escape windows and doors, smoke exhaust windows, ray shielding windows and doors, etc. 2. Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2680 Determination of light transmittance, solar direction transmittance, total solar energy transmittance and ultraviolet transmittance for glass in building and related glazing factors GB/T 5823 Terminology for building windows and doors GB/T 71 06 Graduations and test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors GB/T 8484 Graduation and test method for thermal insulating properties of doors and windows GB/T 8485 Graduation and test method for airborne sound insulating properties of windows and doors GB/T 91 58 Mechanical test methods for windows GB/T 11 976 Graduation and test method of day-lighting properties for external windows GB/T 1 251 3 Fire resistance tests --- Elements of building construction – Glazed elements GB/T 1 41 55 Doorsets --- Soft heavy body impact test GB/T 1 5227 Test method of air permeability, water tightness, wind load resistance performance for curtain walls GB/T 1 5763.1 Safety glazing materials in building --- Part 1 : Fire-resistant glass GB/T 1 5763.4 Safety glazing materials in building --- Part 4: Heat soaked thermally tempered glass GB/T 1 6776 Structural silicone sealants for building GB/T 1 8091 Optical properties of glass curtain walls GB/T 1 8250 Graduations and test method for performance of deformation between stories of curtain wall GB/T 21 086 Curtain wall for building GB/T 29043 Graduation and test method for thermal insulating properties of curtain walls GB/T 29049 Doorsets - Vertical load test GB/T 29530 Hinged or pivoted doors --- Determination of the resistance to static torsion GB/T 29737 Graduations and test method of sand and dust resistance performance for building external windows and doors GB/T 29738 Graduations and test method for performance of exterior windows and doors, curtain walls impacted by windborne debris in windstorm GB/T 29739 Test method of resistance to repeat opening and closing for windows and doors GB/T 29908 Classification and test method of air-blast resistance performance for curtain walls, windows and doors GB/T 30591 Requirements for size coordination for opening of windows and doors in building GB 5001 6 Code of design on building fire protection and prevention GB 50057 Building Lightning Protection Design Code JG/T 397 Method of thermal recycling test for building curtain wall JGJ 1 02 Technical code for glass curtain wall engineering JGJ/T 1 51 Calculation specification for thermal performance of windows, doors and glass curtain walls ISO 1 5822 Test method of doorset opening performance in diagonal deformation ---Seismic aspects 3. Terms and definitions For the purpose of this standard, the terms and definitions given in GB/T 5823 and GB/T 21 086 and the following terms and definitions apply. 3.1 similar design The characteristics that the change in the designs of curtain walls, windows and doors, glasses and hardware etc. or the design of assembly manner not triggering the change of performance 3.2 representative sample The test piece which can represent the results of performance tests of similar design curtain walls, windows or glasses 3.3 fire resistant integrity of windows and doors The capacity of stopping fire flame or hot air passing through or fire flame appearing at the back of fire when one side of building windows and doors get fire under the standard fire resistant test condition 4. Performance classification and selection
Contents of GB/T 31433-2015
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 31433-2015, GB 31433-2015, GBT 31433-2015, GB/T31433-2015, GB/T 31433, GB/T31433, GB31433-2015, GB 31433, GB31433, GBT31433-2015, GBT 31433, GBT31433