2025-6-18 18.97.9.172
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 34682-2017
GB/T 34682-2017   Determination of volatile organic compound(VOC) content in reactive diluent containing coatings (English Version)
Standard No.: GB/T 34682-2017 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 3500 words Price(USD):78.0 remind me the price change

Email:

Implemented on:2018-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 34682-2017
English Name: Determination of volatile organic compound(VOC) content in reactive diluent containing coatings
Chinese Name: 含有活性稀释剂的涂料中挥发性有机化合物(VOC)含量的测定
Professional Classification: GB    National Standard
Issued by: AQSIQ; SAC
Issued on: 2017-11-01
Implemented on: 2018-5-1
Status: valid
Language: English
File Format: PDF
Word Count: 3500 words
Price(USD): 78.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by China Petroleum and Chemical Industry Association. This standard is under the jurisdiction of SAC/TC 5 National Technical Committee on Paints & Pigments of Standardization Administration of China. Determination of volatile organic compound (VOC) content in reactive diluent containing coatings 1 Scope This standard specifies the terms and definitions, principles, instruments and apparatus, samples, test procedures and test data processing for the determination of volatile organic compound (VOC) content in reactive diluent containing coatings. This standard is applicable to the determination of volatile organic compound (VOC) in reactive diluent containing coatings, but not to the determination of volatile organic compound (VOC) content in radiation curable coatings. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3186 Paints, varnishes and raw materials for paints and varnishes - Sampling GB/T 5206-2015 Paints and varnishes - Terms and definitions GB/T 6750 Paints and varnishes - determination of density - Pyknometer method GB/T 6753.4-1998 Paints and varnishes - Determination of flow time by use of flow cups GB/T 9278 Temperatures and humidities for conditioning and testing of paint specimens. GB 18582-2008 Indoor decorating and refurbishing materials - Limit of harmful substances of interior architectural coatings GB/T 20777 Paints and varnishes - Examination and preparation of samples for testing GB/T 21862.2 Paints and varnishes - Determination of density - Part 2: Immersed body (plummet) method GB/T 21862.3 Paints and varnishes - Determination of density - Part 3: Oscillation method GB/T 21862.4 Paints and varnishes - Determination of density - Part 4: Pressure cup method 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 volatile organic compound content; VOC content; VOCC mass of volatile organic compounds contained in coatings measured under specified conditions [GB/T 5206-2015, Definition 2.271] 3.2 reactive diluents also called reactive solvents, which can not only dissolve or disperse film-forming substances, but also participate in the film-forming reaction in the film-forming process of coatings to form non-volatile components to remain in the coating film Note: For example, glycidyl ethers (for epoxy resin coatings), styrene (for unsaturated resin coatings), diethylene glycol-initiated polycaprolactone (for high solid coatings), polyethylene glycol (for high solid coatings), etc. 4 Principle Prepare the specimen according to the stated mixing ratio and dilution ratio of the product. After mixing evenly, determine the non-volatile content in the specimen using the difference method under the specified conditions. If the sample contains moisture, its moisture content shall be determined with Karl Fischer method or gas chromatographic method. If necessary, the density of the specimen shall be determined by an appropriate method based on the type of sample. Finally calculate the VOC content in the specimen. 5 Instruments and apparatus 5.1 Metal flat bottom dish It shall have a diameter of (75±5) mm and an edge height of 5 mm, or it is acceptable provided that the specimen does not overflow. Dishes in different diameters may also be used. In this case, the mass of the specimen used for the test, m, is calculated using Formula (1), in g: (1) where, mstandard——the mass of standard specimen tested, g; d——the bottom diameter of the dish, mm; 75——the standard diameter of the dish, mm. Note: For viscous coatings, aluminum foil with a thickness of about 0.1 mm may be used. Cut the aluminum foil into a rectangle with a size of about (100±10) mm x (300±10) mm that may be folded in half, and fully spread the viscous liquid by gently squeezing the folded parts. 5.2 Syringe Disposable syringe, 10 mL. 5.3 Oven Warning - In order to prevent explosion or fire, samples containing volatile substances shall be handled carefully in accordance with the relevant provisions of China. In order to ensure the safety of the test, a forced convection oven shall be selected, which can be kept within ±2℃ of the specified or agreed temperature, and equipped with a partition that can be horizontally placed. A natural convection oven equipped with a perforated metal partition at 1/3 height of the working chamber may also be used. 5.4 Desiccator Containing suitable desiccant, such as dry silica gel soaked by cobalt chloride. 5.5 Balance With a precision of 1 mg. 6 Samples Take samples either in accordance with the requirements of GB/T 3186, or the agreed method, and the sampling quantity shall be so determined to meet the need of inspection. Examine and prepare the specimens in accordance with the requirements in GB/T 20777.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Instruments and apparatus 6 Sample 7 Test procedures 8 Test data processing
Referred in GB/T 34682-2017:
*GB/T 3186-2006 Paints varnishes and raw materials for paints and varnishes - Sampling
*GB/T 5206-2015 Paints and varnishes―Terms and definitions
*GB/T 6750-2007 Paints and varnishes—Determination of density—Pyknometer method
*GB/T 6753.4-1998 Paints and varnishes-Determination of flow time by use of flow cups
*GB/T 9278-2008 Temperatures and humidities for conditioning and testing of paint specimens
*GB 18582-2008 Indoor decorating and refurbishing materials - Limit of harmful substances of interior architectural coatings
*GB/T 20777-2006 Paints and varnishes - Examination and prepration of samples for testing
*GB/T 21862.2-2008 Paints and varnishes - Determination of density - Part 2: Immersed body (plummet) method
*GB/T 21862.3-2008 Paints and varnishes - Determination of densit - Part 3: Oscillation method
*GB/T 21862.4-2008 Paints and varnishes - Determination of density - Part 4: Pressure cup method
GB/T 34682-2017 is referred in:
*GB/T 35602-2017 Green product assessment—Coating material
*GB 30981-2020 Limit of harmful substances of industrial protective coatings
*GB/T 38597-2020 Technical requirement for low-volatile-organic-compound-content coatings product
*GB 18581-2020 Limit of harmful substances of woodware coatings
*GB/T 4094.2-2017 Electric vehicles-Symbols for controls,indicators and tell-tales
*GBZ/T 250-2014 Radiation shielding specifications for room of industrial X-ray radiography
*GBZ/T 250-2014/XG1-2017 Radiation shielding specifications for room of industrial X-ray radiography, includes Amendment 1
*GB/T 34975-2017 Information security technology-Security technical requirements and testing and evaluation approaches for application software of smart mobile terminals
*GB/T 34823-2017 Endurance test method for agricultural tyres
*GB/T 34708-2017 General Principles for Risk Assessment of Chemicals
*GB/T 34683-2017 Determination of formaldehyde content in waterborne coatings- High performance liquid chromatographic method
Code of China
Standard
GB/T 34682-2017  Determination of volatile organic compound(VOC) content in reactive diluent containing coatings (English Version)
Standard No.GB/T 34682-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3500 words
Price(USD)78.0
Implemented on2018-5-1
Deliveryvia email in 1 business day
Detail of GB/T 34682-2017
Standard No.
GB/T 34682-2017
English Name
Determination of volatile organic compound(VOC) content in reactive diluent containing coatings
Chinese Name
含有活性稀释剂的涂料中挥发性有机化合物(VOC)含量的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2017-11-01
Implemented on
2018-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
3500 words
Price(USD)
78.0
Keywords
GB/T 34682-2017, GB 34682-2017, GBT 34682-2017, GB/T34682-2017, GB/T 34682, GB/T34682, GB34682-2017, GB 34682, GB34682, GBT34682-2017, GBT 34682, GBT34682
Introduction of GB/T 34682-2017
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by China Petroleum and Chemical Industry Association. This standard is under the jurisdiction of SAC/TC 5 National Technical Committee on Paints & Pigments of Standardization Administration of China. Determination of volatile organic compound (VOC) content in reactive diluent containing coatings 1 Scope This standard specifies the terms and definitions, principles, instruments and apparatus, samples, test procedures and test data processing for the determination of volatile organic compound (VOC) content in reactive diluent containing coatings. This standard is applicable to the determination of volatile organic compound (VOC) in reactive diluent containing coatings, but not to the determination of volatile organic compound (VOC) content in radiation curable coatings. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3186 Paints, varnishes and raw materials for paints and varnishes - Sampling GB/T 5206-2015 Paints and varnishes - Terms and definitions GB/T 6750 Paints and varnishes - determination of density - Pyknometer method GB/T 6753.4-1998 Paints and varnishes - Determination of flow time by use of flow cups GB/T 9278 Temperatures and humidities for conditioning and testing of paint specimens. GB 18582-2008 Indoor decorating and refurbishing materials - Limit of harmful substances of interior architectural coatings GB/T 20777 Paints and varnishes - Examination and preparation of samples for testing GB/T 21862.2 Paints and varnishes - Determination of density - Part 2: Immersed body (plummet) method GB/T 21862.3 Paints and varnishes - Determination of density - Part 3: Oscillation method GB/T 21862.4 Paints and varnishes - Determination of density - Part 4: Pressure cup method 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 volatile organic compound content; VOC content; VOCC mass of volatile organic compounds contained in coatings measured under specified conditions [GB/T 5206-2015, Definition 2.271] 3.2 reactive diluents also called reactive solvents, which can not only dissolve or disperse film-forming substances, but also participate in the film-forming reaction in the film-forming process of coatings to form non-volatile components to remain in the coating film Note: For example, glycidyl ethers (for epoxy resin coatings), styrene (for unsaturated resin coatings), diethylene glycol-initiated polycaprolactone (for high solid coatings), polyethylene glycol (for high solid coatings), etc. 4 Principle Prepare the specimen according to the stated mixing ratio and dilution ratio of the product. After mixing evenly, determine the non-volatile content in the specimen using the difference method under the specified conditions. If the sample contains moisture, its moisture content shall be determined with Karl Fischer method or gas chromatographic method. If necessary, the density of the specimen shall be determined by an appropriate method based on the type of sample. Finally calculate the VOC content in the specimen. 5 Instruments and apparatus 5.1 Metal flat bottom dish It shall have a diameter of (75±5) mm and an edge height of 5 mm, or it is acceptable provided that the specimen does not overflow. Dishes in different diameters may also be used. In this case, the mass of the specimen used for the test, m, is calculated using Formula (1), in g: (1) where, mstandard——the mass of standard specimen tested, g; d——the bottom diameter of the dish, mm; 75——the standard diameter of the dish, mm. Note: For viscous coatings, aluminum foil with a thickness of about 0.1 mm may be used. Cut the aluminum foil into a rectangle with a size of about (100±10) mm x (300±10) mm that may be folded in half, and fully spread the viscous liquid by gently squeezing the folded parts. 5.2 Syringe Disposable syringe, 10 mL. 5.3 Oven Warning - In order to prevent explosion or fire, samples containing volatile substances shall be handled carefully in accordance with the relevant provisions of China. In order to ensure the safety of the test, a forced convection oven shall be selected, which can be kept within ±2℃ of the specified or agreed temperature, and equipped with a partition that can be horizontally placed. A natural convection oven equipped with a perforated metal partition at 1/3 height of the working chamber may also be used. 5.4 Desiccator Containing suitable desiccant, such as dry silica gel soaked by cobalt chloride. 5.5 Balance With a precision of 1 mg. 6 Samples Take samples either in accordance with the requirements of GB/T 3186, or the agreed method, and the sampling quantity shall be so determined to meet the need of inspection. Examine and prepare the specimens in accordance with the requirements in GB/T 20777.
Contents of GB/T 34682-2017
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Instruments and apparatus 6 Sample 7 Test procedures 8 Test data processing
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 34682-2017, GB 34682-2017, GBT 34682-2017, GB/T34682-2017, GB/T 34682, GB/T34682, GB34682-2017, GB 34682, GB34682, GBT34682-2017, GBT 34682, GBT34682