2023-6-7 44.192.79.149
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/MT/T 575-2011
MT/T 575-2011   YBRB series flameproof three phases asynchronous motor for pump (English Version)
Standard No.: MT/T 575-2011 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 6000 words Price(USD):120.0 remind me the price change

Email:

Implemented on:2011-9-1 Delivery: via email in 1 business day
,,
Standard No.: MT/T 575-2011
English Name: YBRB series flameproof three phases asynchronous motor for pump
Chinese Name: YBRB系列 泵用隔爆型三相异步电动机
Professional Classification: MT    Professional Standard - Coal
Issued by: SAWS
Issued on: 2011-4-12
Implemented on: 2011-9-1
Status: valid
Superseding:MT/T 575-1996
Language: English
File Format: PDF
Word Count: 6000 words
Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This standard specifies the types and basic parameters, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of YBRB series flameproof three phase asynchronous motor for pump (hereinafter referred to as motor). This standard is applicable to motors used for emulsion pump station and atomizing pump, as for motors used for shearer and development machine as well as other similar mechanical fuel pumps for mining purpose, this standard can be referred to. 2 Normative References The following documents are indispensable for the application of this standard. For dated references, only the dated edition is applicable to this document. For undated references, the latest editions of the normative documents (including all the amendments) are applicable to this document. GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods GB 755-2008 Rotating Electrical Machines - Rating and Performance GB/T 997-2008 Rotating Electrical Machines - Classification of Types of Construction Mounting Arrangements and Terminal Box Position of (IM Code) GB/T 1032-2005 Test Procedures for Three-phase Induction Motors GB/T 1993-1993 Cooling Methods for Rotating Electrical Machines GB/T 2423.4-2008 Environmental Testing for Electric and Electronic Products - Part 2: Test Method - Test Db: Damp Heat, Cyclic (12h+12h Cycle) GB 3836.1-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements GB 3836.2-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Flameproof Enclosure D GB 3836.3-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 3: Increased Safety GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines -Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1,080 GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification GB 10068-2008 Mechanical Vibration of Certain Machines with Shaft Heights 56 Mm and Higher - Measurement Evaluation and Limits of Vibration Severity GB/T 10069.1-2006 Measurement of Airborne Noise Emitted by Rotating Electrical Machines and the Noise Limits Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines GB/T 10111-2008 Generation of Random Numbers and Procedures Applied to Sampling Inspection for Product Quality AQ 1043-2007 Mining Products Safety Label JB/T 9615.1-2000 Test Methods of the Inter-turn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Inter-turn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10098-2000 Impulse Voltage Withstand Levels of Rotating A.C. Machines with Form-wound Stator Coils 3 Types and Basic Parameters 3.1 Types 3.1.1 Flameproof motor shall be manufactured according to the requirements of GB 3836.2-2000 with flameproof mark of Exd I. 3.1.2 The overall structure protection degree of the motor shall meet the IP55 specified in GB/T 4942.1-2006. 3.1.3 Cooling mode of motor is enclosure water cooling type or air cooling type, which shall meet the requirements of GB/T 1993-1993; the mark of cooling mode is IC3W7 or IC0141.
Foreword I 1 Scope 2 Normative References 3 Types and Basic Parameters 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking, Packaging, Transportation and Storage Appendix A (Informative) Installation Dimension and Tolerance of Flameproof Three Phases Asynchronous Motor for Pump
Referred in MT/T 575-2011:
* GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
* GB 755-2008 Rotating Electrical Machines - Rating and Performance
* GB/T 997-2008 Rotating Electrical Machines—Classification of Types of Construction, Mounting Arrangements and Terminal Box Position (IM Code)
* GB/T 1032-2005 Test procedures for three-phase induction motors
* GB/T 1993-1993 Cooling methods for rotating electrical machines
* GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat,cyclic ( 12h+12h cycle)
* GB 3836.1-2000
* GB 3836.2-2000
* GB 3836.3-2000
* GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines -Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1 080
* GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
* GB 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher-measurement evaluation and limits of vibration severity
* GB/T 10069.1-2006 Measurement of airborne noise emitted by rotating electrical machines and the noise limits Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines
* GB/T 10111-2008 Generation of random numbers and procedures applied to sampling inspection for product quality
* AQ 1043-2007 Mining Products Safety Label
* JB/T 9615.1-2000 Test methods of the interturn insulation on random wound winding for AC low-voltage machines
* JB/T 9615.2-2000 Test limits of the interturn insulation on random wound winding for AC low-voltage machines
* JB/T 10098-2000 Impulse voltage withstand levels of rotating a.c. machines with form-wound stator coils
Code of China
Standard
MT/T 575-2011  YBRB series flameproof three phases asynchronous motor for pump (English Version)
Standard No.MT/T 575-2011
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)120.0
Implemented on2011-9-1
Deliveryvia email in 1 business day
Detail of MT/T 575-2011
Standard No.
MT/T 575-2011
English Name
YBRB series flameproof three phases asynchronous motor for pump
Chinese Name
YBRB系列 泵用隔爆型三相异步电动机
Chinese Classification
Professional Classification
MT
ICS Classification
Issued by
SAWS
Issued on
2011-4-12
Implemented on
2011-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
MT/T 575-1996
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
120.0
Keywords
MT/T 575-2011, MT 575-2011, MTT 575-2011, MT/T575-2011, MT/T 575, MT/T575, MT575-2011, MT 575, MT575, MTT575-2011, MTT 575, MTT575
Introduction of MT/T 575-2011
1 Scope This standard specifies the types and basic parameters, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of YBRB series flameproof three phase asynchronous motor for pump (hereinafter referred to as motor). This standard is applicable to motors used for emulsion pump station and atomizing pump, as for motors used for shearer and development machine as well as other similar mechanical fuel pumps for mining purpose, this standard can be referred to. 2 Normative References The following documents are indispensable for the application of this standard. For dated references, only the dated edition is applicable to this document. For undated references, the latest editions of the normative documents (including all the amendments) are applicable to this document. GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods GB 755-2008 Rotating Electrical Machines - Rating and Performance GB/T 997-2008 Rotating Electrical Machines - Classification of Types of Construction Mounting Arrangements and Terminal Box Position of (IM Code) GB/T 1032-2005 Test Procedures for Three-phase Induction Motors GB/T 1993-1993 Cooling Methods for Rotating Electrical Machines GB/T 2423.4-2008 Environmental Testing for Electric and Electronic Products - Part 2: Test Method - Test Db: Damp Heat, Cyclic (12h+12h Cycle) GB 3836.1-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements GB 3836.2-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Flameproof Enclosure D GB 3836.3-2000 Electrical Apparatus for Explosive Gas Atmospheres - Part 3: Increased Safety GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines -Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1,080 GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification GB 10068-2008 Mechanical Vibration of Certain Machines with Shaft Heights 56 Mm and Higher - Measurement Evaluation and Limits of Vibration Severity GB/T 10069.1-2006 Measurement of Airborne Noise Emitted by Rotating Electrical Machines and the Noise Limits Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines GB/T 10111-2008 Generation of Random Numbers and Procedures Applied to Sampling Inspection for Product Quality AQ 1043-2007 Mining Products Safety Label JB/T 9615.1-2000 Test Methods of the Inter-turn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Inter-turn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10098-2000 Impulse Voltage Withstand Levels of Rotating A.C. Machines with Form-wound Stator Coils 3 Types and Basic Parameters 3.1 Types 3.1.1 Flameproof motor shall be manufactured according to the requirements of GB 3836.2-2000 with flameproof mark of Exd I. 3.1.2 The overall structure protection degree of the motor shall meet the IP55 specified in GB/T 4942.1-2006. 3.1.3 Cooling mode of motor is enclosure water cooling type or air cooling type, which shall meet the requirements of GB/T 1993-1993; the mark of cooling mode is IC3W7 or IC0141.
Contents of MT/T 575-2011
Foreword I 1 Scope 2 Normative References 3 Types and Basic Parameters 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking, Packaging, Transportation and Storage Appendix A (Informative) Installation Dimension and Tolerance of Flameproof Three Phases Asynchronous Motor for Pump
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
MT/T 575-2011, MT 575-2011, MTT 575-2011, MT/T575-2011, MT/T 575, MT/T575, MT575-2011, MT 575, MT575, MTT575-2011, MTT 575, MTT575