2025-5-16 18.97.9.170
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY 0585.2-2019
YY 0585.2-2019   Fluid lines for use with pressure infusion equipment and accessories for single use—Part 2:Accessories (English Version)
Standard No.: YY 0585.2-2019 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5500 words Price(USD):165.0 remind me the price change

Email:

Implemented on:2020-12-1 Delivery: via email in 1 business day
,,
Standard No.: YY 0585.2-2019
English Name: Fluid lines for use with pressure infusion equipment and accessories for single use—Part 2:Accessories
Chinese Name: 压力输液设备用一次性使用液路及附件 第2部分:附件
Chinese Classification: C31    General and microsurgical devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.20 11.040.20    Transfusion, infusion and injection equipment 11.040.20
Issued by: National Medical Products Adminstration
Issued on: 2019-05-31
Implemented on: 2020-12-1
Status: valid
Superseding:YY 0585.2-2005 Fluid lines for use with pressure infusion equipment and accessories for single use - Part 2: Accessories
Language: English
File Format: PDF
Word Count: 5500 words
Price(USD): 165.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. YY 0585 consists of the following parts under the general title Fluid lines for use with pressure infusion equipment and accessories for single use: ——Part 1: Fluid lines; ——Part 2: Accessories; ——Part 3: Filters; ——Part 4: Check valves. This is Part 2 of YY 0585. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces YY 0585.2-2005. An informative Annex D is added behind Annexes A, B and C, and in addition to editorial changes, the following main technical changes have been made with respect to YY 0585.2-2005. ——The degree of standard adoption is modified from “IDT” (identical adoption) to “MOD” (modified adoption); ——The marking of Clause 3 is deleted; ——The requirements for unit with injection site in 4.8 are modified; ——The requirements for unit with check valve in 4.9 are modified, and A.8 is deleted; ——The biological requirements in Clause 6 is modified to be applicable to GB 8368 to facilitate implementation; ——The labeling requirements in Clause 8 are modified. The requirement that the symbol 2725 of ISO 7000 can be used to indicate the presence of a substance of concern is added; ——The disposal requirements in Clause 9 are added; ——The method of test for leakage in A.4 is modified and the negative pressure test is deleted; ——The leakage test for adapters with female and/or male conical fittings in A.5 is deleted. This part is modified in relation to ISO 8536-10: 2015 Infusion equipment for medical use—Part 10: Accessories for fluid lines for single use with pressure infusion equipment. Technical differences have been made in this part with respect to ISO 8536-10: 2015, and relevant technical differences and their causes have been listed in Annex D. The following editorial changes have been made in this part: ——Informative Annex D is added, giving a list of corresponding technical differences and their causes compared with ISO 8536-10: 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this standard shall not be held responsible for identifying any or all such patent rights. This part was proposed by the National Medical Products Administration of People’s Republic of China. This part is under the jurisdiction of the National Technical Committee 106 on Medical Syringes of Standardization Administration of China. The previous edition of this part is as follows: ——YY 0585.2-2005. Fluid lines for use with pressure infusion equipment and accessories for single use— Part 2: Accessories 1 Scope This part of YY 0585 specifies the physical, chemical and biological requirements of accessories for pressure infusion equipment. This part applies to sterilized accessories for single use in fluid lines and pressure infusion equipment as specified in YY 0286.4, including: a) two-way stopcocks (2SC), three-way stopcocks (3SC), four-way stopcocks (4SC), and stopcocks manifold (SM); Note: Designation of a stopcock depends on the number of connections. The number of possible functional positions can be expressed by addition of a complementary note, using a diagonal stroke and a numeral indicating the number of possible stopcock positions, e.g., 3/4-way stopcock for three-way stopcock with four possible positions. b) units with injection site (UIS) or check valve (UCV); c) stoppers or adapters. 2 Normative references The following documents are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1962.21) Conical fitting with a 6% (Luer) taper for syringes, needles and certain other medical equipment—Part2: Lock fittings (GB/T 1962.2-2001, ISO 594-2: 1998, IDT) GB 8368 Infusion sets for single use—Gravity feed (GB 8368-2018, ISO 8536-4: 2010, MOD) YY 0286.4 Special infusion sets—Part 4: Infusion sets for single use pressure infusion apparatus (YY 0286.4-2006, ISO 8536-8: 2004, IDT)   YY/T 0466.1 Medical devices—Symbols to be used with medical device labels, labelling and information to be supplied—Part 1: General requirements (YY/T 0466.1-2016, ISO 15223-1: 2012, IDT) YY 0585.4 Fluid lines for use with pressure infusion equipment and accessories for single use—Part 4: Accessories (YY 0585.4-2009, ISO 8536-12: 2007, MOD) Pharmacopoeia of the People's Republic of China 3 Materials The materials from which the accessories are manufactured shall comply with the requirements as specified in Clause 4, Clause 5, and Clause 6. 4 Physical requirements 4.1 Avoidance of air bubbles All components of accessories shall be designed such that no air bubbles are detected in flow channels when tested as specified in A.1. 4.2 Particulate contamination The accessories shall be manufactured under conditions that minimize particulate contamination. The fluid pathway surfaces shall be smooth and clean. When tested as specified in A.2, the number of particles shall not exceed the contamination index. 4.3 Tensile strength When tested as specified in A.3, the accessories and connections (except for protective caps) between components shall withstand a static tensile force of not less than 15N for 15s. In the case of stopcocks, connections between plug and housing shall withstand this tensile force when in any position. 4.4 Leakage The accessories shall be impermeable to air, microorganisms, and fluids. Stopcocks shall be tight in any plug position. When tested as specified in A.4, there shall be no leakage of air or water.   4.5 Adapters with female and/or male conical fittings Adapters shall be provided with a connector with female conical fitting and/or a connector with male conical fitting according to GB/T 1962.2. 4.6 Protective caps GB/T 8368 applies. 4.7 Manipulation of stopcocks Stopcocks and stopcock manifolds shall be so designed that when tested as specified in A.5, flow channels can be opened and closed without any adverse effect on the functionality of adjacent components. 4.8 Unit with injection site Units with injection site shall enable injection. When tested as specified in A.6, no more than 2 drops per unit shall be lost. 4.9 Unit with check valve Unit with check valve shall meet the requirements specified in YY 0585.4. 5 Chemical requirements GB 8368 applies. For test methods, see Annex B. 6 Biological requirements GB 8368 applies. For test methods, see Annex C.
Foreword i 1 Scope 2 Normative references 3 Materials 4 Physical requirements 5 Chemical requirements 6 Biological requirements 7 Packaging 8 Labeling 9 Disposal Annex A (Normative) Physical tests Annex B (Normative) Chemical tests Annex C (Normative) Biological tests Annex D (Informative) Technical differences between this part and ISO 8536-10: 2015 and their causes Bibliography
Referred in YY 0585.2-2019:
*GB/T 1962.2-2001 Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
*GB 8368-2018 Infusion sets for single use—Gravity feed
*YY 0286.4-2006 Special infusion sets - Part 4: Single-use infusion equipment for use with pressure infusion apparatus
*YY/T 0466.1-2016 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
*YY 0585.4-2009 Fluid lines for use with pressure infusion equipment and accessories for single use - Part 4: Check valves
*GB 18278.1-2015 Sterilization of health care products―Moist heat―Part 1:Requirements for the development, validation and routine control of a sterilization process for medical devices
*GB 18279.1-2015 Sterilization of health care products―Ethylene oxide―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices
*GB 18280.1-2015 Sterilization of health care products―Radiation―Part 1:Requirements for development,validation and routine control of a sterilization process for medical devices
*GB 18280.2-2015 Sterilization of health care products―Radiation―Part 2:Establishing the sterilization dose
YY 0585.2-2019 is referred in:
*WS/T 220-2002 Determination of coagulant factor activities--General guideline
*DB11/T 849-2011 Operating specification for appraisal and structure inspection of building
*DB42/T 855-2012 Wufeng Green Tea - The geographical indication trademarks
*GB 10573-1989 Tensile testing method for fine wire of non-ferrous metals
*DB31/ 590-2012 The norm of energy consumption per unit product of wrought aluminium and aluminium alloy ingot for casting
*DB522200/T 71-2009
*DB14/T 714-2012 Construction guideline for bridges and culverts of expressway
*LS/T 1201-2002 Fumigation regulation of phosphine recirculation
*DB14/T 715-2012 Construction guidelines for bridge and culvert of expressway
*DB45/T 210-2017 Product of geographical indication - Rongxian Shatian Pomelo
*DB22/T 1152-2009 Safe production technique rules of Gloestereum incarnated
*HAD002/01-2010
*JGJ/T 466-2019 Technical standard for light steel modular building
*SY/T 0041-1997 Test method for apparent shear strength of pipeline coatings to metal
Code of China
Standard
YY 0585.2-2019  Fluid lines for use with pressure infusion equipment and accessories for single use—Part 2:Accessories (English Version)
Standard No.YY 0585.2-2019
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2020-12-1
Deliveryvia email in 1 business day
Detail of YY 0585.2-2019
Standard No.
YY 0585.2-2019
English Name
Fluid lines for use with pressure infusion equipment and accessories for single use—Part 2:Accessories
Chinese Name
压力输液设备用一次性使用液路及附件 第2部分:附件
Chinese Classification
C31
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2019-05-31
Implemented on
2020-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
YY 0585.2-2005 Fluid lines for use with pressure infusion equipment and accessories for single use - Part 2: Accessories
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
YY 0585.2-2019, YY/T 0585.2-2019, YYT 0585.2-2019, YY0585.2-2019, YY 0585.2, YY0585.2, YY/T0585.2-2019, YY/T 0585.2, YY/T0585.2, YYT0585.2-2019, YYT 0585.2, YYT0585.2
Introduction of YY 0585.2-2019
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. YY 0585 consists of the following parts under the general title Fluid lines for use with pressure infusion equipment and accessories for single use: ——Part 1: Fluid lines; ——Part 2: Accessories; ——Part 3: Filters; ——Part 4: Check valves. This is Part 2 of YY 0585. This part is developed in accordance with the rules given in GB/T 1.1-2009. This part replaces YY 0585.2-2005. An informative Annex D is added behind Annexes A, B and C, and in addition to editorial changes, the following main technical changes have been made with respect to YY 0585.2-2005. ——The degree of standard adoption is modified from “IDT” (identical adoption) to “MOD” (modified adoption); ——The marking of Clause 3 is deleted; ——The requirements for unit with injection site in 4.8 are modified; ——The requirements for unit with check valve in 4.9 are modified, and A.8 is deleted; ——The biological requirements in Clause 6 is modified to be applicable to GB 8368 to facilitate implementation; ——The labeling requirements in Clause 8 are modified. The requirement that the symbol 2725 of ISO 7000 can be used to indicate the presence of a substance of concern is added; ——The disposal requirements in Clause 9 are added; ——The method of test for leakage in A.4 is modified and the negative pressure test is deleted; ——The leakage test for adapters with female and/or male conical fittings in A.5 is deleted. This part is modified in relation to ISO 8536-10: 2015 Infusion equipment for medical use—Part 10: Accessories for fluid lines for single use with pressure infusion equipment. Technical differences have been made in this part with respect to ISO 8536-10: 2015, and relevant technical differences and their causes have been listed in Annex D. The following editorial changes have been made in this part: ——Informative Annex D is added, giving a list of corresponding technical differences and their causes compared with ISO 8536-10: 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this standard shall not be held responsible for identifying any or all such patent rights. This part was proposed by the National Medical Products Administration of People’s Republic of China. This part is under the jurisdiction of the National Technical Committee 106 on Medical Syringes of Standardization Administration of China. The previous edition of this part is as follows: ——YY 0585.2-2005. Fluid lines for use with pressure infusion equipment and accessories for single use— Part 2: Accessories 1 Scope This part of YY 0585 specifies the physical, chemical and biological requirements of accessories for pressure infusion equipment. This part applies to sterilized accessories for single use in fluid lines and pressure infusion equipment as specified in YY 0286.4, including: a) two-way stopcocks (2SC), three-way stopcocks (3SC), four-way stopcocks (4SC), and stopcocks manifold (SM); Note: Designation of a stopcock depends on the number of connections. The number of possible functional positions can be expressed by addition of a complementary note, using a diagonal stroke and a numeral indicating the number of possible stopcock positions, e.g., 3/4-way stopcock for three-way stopcock with four possible positions. b) units with injection site (UIS) or check valve (UCV); c) stoppers or adapters. 2 Normative references The following documents are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1962.21) Conical fitting with a 6% (Luer) taper for syringes, needles and certain other medical equipment—Part2: Lock fittings (GB/T 1962.2-2001, ISO 594-2: 1998, IDT) GB 8368 Infusion sets for single use—Gravity feed (GB 8368-2018, ISO 8536-4: 2010, MOD) YY 0286.4 Special infusion sets—Part 4: Infusion sets for single use pressure infusion apparatus (YY 0286.4-2006, ISO 8536-8: 2004, IDT)   YY/T 0466.1 Medical devices—Symbols to be used with medical device labels, labelling and information to be supplied—Part 1: General requirements (YY/T 0466.1-2016, ISO 15223-1: 2012, IDT) YY 0585.4 Fluid lines for use with pressure infusion equipment and accessories for single use—Part 4: Accessories (YY 0585.4-2009, ISO 8536-12: 2007, MOD) Pharmacopoeia of the People's Republic of China 3 Materials The materials from which the accessories are manufactured shall comply with the requirements as specified in Clause 4, Clause 5, and Clause 6. 4 Physical requirements 4.1 Avoidance of air bubbles All components of accessories shall be designed such that no air bubbles are detected in flow channels when tested as specified in A.1. 4.2 Particulate contamination The accessories shall be manufactured under conditions that minimize particulate contamination. The fluid pathway surfaces shall be smooth and clean. When tested as specified in A.2, the number of particles shall not exceed the contamination index. 4.3 Tensile strength When tested as specified in A.3, the accessories and connections (except for protective caps) between components shall withstand a static tensile force of not less than 15N for 15s. In the case of stopcocks, connections between plug and housing shall withstand this tensile force when in any position. 4.4 Leakage The accessories shall be impermeable to air, microorganisms, and fluids. Stopcocks shall be tight in any plug position. When tested as specified in A.4, there shall be no leakage of air or water.   4.5 Adapters with female and/or male conical fittings Adapters shall be provided with a connector with female conical fitting and/or a connector with male conical fitting according to GB/T 1962.2. 4.6 Protective caps GB/T 8368 applies. 4.7 Manipulation of stopcocks Stopcocks and stopcock manifolds shall be so designed that when tested as specified in A.5, flow channels can be opened and closed without any adverse effect on the functionality of adjacent components. 4.8 Unit with injection site Units with injection site shall enable injection. When tested as specified in A.6, no more than 2 drops per unit shall be lost. 4.9 Unit with check valve Unit with check valve shall meet the requirements specified in YY 0585.4. 5 Chemical requirements GB 8368 applies. For test methods, see Annex B. 6 Biological requirements GB 8368 applies. For test methods, see Annex C.
Contents of YY 0585.2-2019
Foreword i 1 Scope 2 Normative references 3 Materials 4 Physical requirements 5 Chemical requirements 6 Biological requirements 7 Packaging 8 Labeling 9 Disposal Annex A (Normative) Physical tests Annex B (Normative) Chemical tests Annex C (Normative) Biological tests Annex D (Informative) Technical differences between this part and ISO 8536-10: 2015 and their causes Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
YY 0585.2-2019, YY/T 0585.2-2019, YYT 0585.2-2019, YY0585.2-2019, YY 0585.2, YY0585.2, YY/T0585.2-2019, YY/T 0585.2, YY/T0585.2, YYT0585.2-2019, YYT 0585.2, YYT0585.2