YY 0785-2010   Clinical thermometers—Performance of electrical thermometers for continuous measurement (English Version)
Standard No.: YY 0785-2010 Status:to be superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 7000 words Price(USD):210.0 remind me the price change

Email:

Implemented on:2012-6-1 Delivery: via email in 1 business day
,,
Standard No.: YY 0785-2010
English Name: Clinical thermometers—Performance of electrical thermometers for continuous measurement
Chinese Name: 临床体温计——连续测量的电子体温计性能要求
Chinese Classification: C39    Medical electronic equipment
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.55 11.040.55    Diagnostic equipment 11.040.55
Issued by: SDA
Issued on: 2010-12-27
Implemented on: 2012-6-1
Status: to be superseded
Superseded by:YY 9706.256-2023 Medical electrical equipment--Part 2-56: Particular requirements for basicsafety and essential performance of clinical thermometers for body temperature measurement
Superseded on:2026-5-1
Language: English
File Format: PDF
Word Count: 7000 words
Price(USD): 210.0
Delivery: via email in 1 business day
Clinical thermometers - Performance of electrical thermometers for continuous measurement 1 Scope This standard specifies the performance requirements for electrical thermometers for continuous measurements. This standard is applicable to devices that are operated by an electrical power supply either by mains or internal power sources. The devices can be equipped to accommodate indicators, printing devices, and other auxiliary devices. The requirements for such accessories are not covered by this standard. Thermometers intended to measure skin temperatures are not covered by this standard. This standard does not intend to exclude the applicability of any device based on other measuring principles that provides an equivalent performance in continuously measuring body temperature. Note: Devices can have functions which are covered by different parts of EN 12470 (see Annex A). In this case, it is the responsibility of the manufacturer to indicate by which part of EN 12470 the function is covered, e.g. electrical thermometer with maximum device and exchangeable temperature probes. 2 Normative references The following documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding any corrigendum), or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the document referred to applies. GB/T 2423.22-2002 Environmental testing for electric and electronic products - Part 2: Test methods Test N: Change of temperature (IEC 60068-2-14: 1984, IDT) GB/T 2828.2-2008 Sampling procedures for inspection by attributes - Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection (ISO 2859-2:1985, NEQ) GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT) GB/T 16886.1 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process (GB/T 16886.1-2011; ISO 0993-1:2009) YY 0466-2003 Medical devices - Symbols to be used with medical device labels labelling and information to be supplied (ISO 15223:2000, IDT) YY 0505-2005 Medical electrical equipment - Part 1-2: General requirements for safety - Collateral Standards: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2: 2001, IDT) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 continuously measuring electrical thermometer device that continuously measures and displays the temperature of the human body and consists of an indicating unit and a connected temperature probe
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Units 5 Types of thermometers 6 Requirements 7 Test method 8 Information supplied by the manufacturer Annex A (Informative) Series standards of EN 12470
Referred in YY 0785-2010:
*GB/T 2423.22-2002 Environmental testing for electric and electronic products - Part 2: Test methods Test N: Change of temperature
*GB/T 2828.2-2008 Sampling procedures for inspection by attributes - Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
*GB 9706.1-2007 Medical electrical equipment—Part 1:General requirements for safety
*GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
*YY 0466-2003 Medical devices -- Symbols to be used with medical device labels labelling and information to be supplied
*YY 0505-2005 Medical electrical equipment?Part 1-2: General requirements for safety?Collateral stanards: Electromagnetic compatibility?Requirements and tests
Code of China
Standard
YY 0785-2010  Clinical thermometers—Performance of electrical thermometers for continuous measurement (English Version)
Standard No.YY 0785-2010
Statusto be superseded
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)210.0
Implemented on2012-6-1
Deliveryvia email in 1 business day
Detail of YY 0785-2010
Standard No.
YY 0785-2010
English Name
Clinical thermometers—Performance of electrical thermometers for continuous measurement
Chinese Name
临床体温计——连续测量的电子体温计性能要求
Chinese Classification
C39
Professional Classification
YY
ICS Classification
Issued by
SDA
Issued on
2010-12-27
Implemented on
2012-6-1
Status
to be superseded
Superseded by
YY 9706.256-2023 Medical electrical equipment--Part 2-56: Particular requirements for basicsafety and essential performance of clinical thermometers for body temperature measurement
Superseded on
2026-5-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
210.0
Keywords
YY 0785-2010, YY/T 0785-2010, YYT 0785-2010, YY0785-2010, YY 0785, YY0785, YY/T0785-2010, YY/T 0785, YY/T0785, YYT0785-2010, YYT 0785, YYT0785
Introduction of YY 0785-2010
Clinical thermometers - Performance of electrical thermometers for continuous measurement 1 Scope This standard specifies the performance requirements for electrical thermometers for continuous measurements. This standard is applicable to devices that are operated by an electrical power supply either by mains or internal power sources. The devices can be equipped to accommodate indicators, printing devices, and other auxiliary devices. The requirements for such accessories are not covered by this standard. Thermometers intended to measure skin temperatures are not covered by this standard. This standard does not intend to exclude the applicability of any device based on other measuring principles that provides an equivalent performance in continuously measuring body temperature. Note: Devices can have functions which are covered by different parts of EN 12470 (see Annex A). In this case, it is the responsibility of the manufacturer to indicate by which part of EN 12470 the function is covered, e.g. electrical thermometer with maximum device and exchangeable temperature probes. 2 Normative references The following documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding any corrigendum), or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the document referred to applies. GB/T 2423.22-2002 Environmental testing for electric and electronic products - Part 2: Test methods Test N: Change of temperature (IEC 60068-2-14: 1984, IDT) GB/T 2828.2-2008 Sampling procedures for inspection by attributes - Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection (ISO 2859-2:1985, NEQ) GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT) GB/T 16886.1 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process (GB/T 16886.1-2011; ISO 0993-1:2009) YY 0466-2003 Medical devices - Symbols to be used with medical device labels labelling and information to be supplied (ISO 15223:2000, IDT) YY 0505-2005 Medical electrical equipment - Part 1-2: General requirements for safety - Collateral Standards: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2: 2001, IDT) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 continuously measuring electrical thermometer device that continuously measures and displays the temperature of the human body and consists of an indicating unit and a connected temperature probe
Contents of YY 0785-2010
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Units 5 Types of thermometers 6 Requirements 7 Test method 8 Information supplied by the manufacturer Annex A (Informative) Series standards of EN 12470
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
YY 0785-2010, YY/T 0785-2010, YYT 0785-2010, YY0785-2010, YY 0785, YY0785, YY/T0785-2010, YY/T 0785, YY/T0785, YYT0785-2010, YYT 0785, YYT0785