(Building Part)2013   Compulsory Provisions of Engineering Construction Standards (Building Part) 2013 (English Version)
Standard No.: (Building Part)2013 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 260000 words Translation Price(USD):2100.0 remind me the price change

Email:

Implemented on: Delivery: via email in 1 business day

→ → →

,,,8CB69868F18F85431412761783411
Standard No.: (Building Part)2013
English Name: Compulsory Provisions of Engineering Construction Standards (Building Part) 2013
Chinese Name: 工程建设标准强制性条文(房屋建筑部分) 2013
Professional Classification: (B    
Source Content Issued by: MOHURD
Status: valid
Target Language: English
File Format: PDF
Word Count: 260000 words
Translation Price(USD): 2100.0
Delivery: via email in 1 business day
1 Basic Requirements GB 50352-2005 Code for design of civil buildings 4.2.1 The buildings and the attached facilities must not be constructed which extrude the boundary line of roads and filed, the architectural outshoot that can not extrude are: ----Underground building and attached facilities, including structural retaining pile, retaining wall, basement, bottom plate and its foundation of basement, cesspool and so on; ----Up-ground building and attached facilities, including porch, corridor, balcony, outdoor stair, step, ramp, flower pool, enclosure, platform, apron open sewer, air inlet and outlet of basement, passageway of basement, inlet well, light well and so on; ----Other facilities except connecting the city’s municipal public facilities like pipelines, funnels, over bridges and so on in the site. 6.6.3 Protective railing shall be set for such free positions as balcony, side corridor, indoor circular corridor, interior courtyard, person bearing roof and outdoor stair, and comply with 1 Railing shall be fabricated by firm and perdurable materials, and able to bear horizontal load prescribed in load specifications; 4 Structures preventing children climbing must be adopted for railings in residences, nursery, kindergarten, primary/secondary school and special places for children, and clear distance between railings shall be no more than 0.11m when vertical rail is adopted; 6.7.2 Except for complying with regulations of fire prevention code, horizontal distance between wall surface and center line of railing or between railings, namely width of stair horse, for daily major traffic shall be determined by the number of pedestrian flow of 0.55+(0-0.15)m, and the number shall be no less than two. 0~0.15m is oscillation amplitude of human body in marching pedestrian flow, and upper limit value shall be taken for public buildings with crowd pedestrian flow. 6.7.9 Measures to prevent children from climbing and sliding must be adopted for stairs in nursery, kindergarten, primary/secondary school and special places for children when clear width of stair well exceeds 0.20m,and structures hard to climb shall be adopted for railing of stair, Clear distance between railings shall be no more than 0.11m when vertical rail is adopted; 6.12.5 For the room used as storage of food, foodstuff, seed or drugs, it is forbidden to use toxic materials as flooring when stored materials directly contacted with flooring, and the toxicity of materials shall be identified by relevant hygiene and disease control departments. Flooring materials with foreign flavor emitting shall not be adopted for stored food with strong flavor adsorption ability. 6.14.1 Pipe shaft, smoke flue, air relief shaft and garbage shaft shall be independently set and mustn’t be incorporated in one pipe system. In addition, they shall be fabricated by non-combustible materials. 2 Indoor Environment 2.1 Thermopower GB 50176-93 Thermal design code for civil building 3.2.5 Fender structures like external wall, roof and floor slab directly contact the outside air, or the partition of staircase without heating shall be calculated with thermal insulation, and its heat transfer resistance shall be greater than or equal to the minimum heat transfer resistance required by the building-based region. 4.3.1 The internal surface temperature of the thermal bridge part of the fender structure shall not be lower than the dew-point temperature of the indoor air. 4.4.4 The air tightness of the external window of the residential building and public buildings shall be in accordance with the following requirements: 1. in region with outdoor average wind velocity in winter of greater than or equal to 3.0m/s, the 1~6 floors building shall not be lower than III-level specified in current national standard "Graduation of Air Permeability and Their Test Method for Windows" GB7107; for 7~30 floors building, it shall not be lower than II-level specified in the above standard. 1. in region with outdoor average wind velocity in winter of less than 3.0m/s, the 1~6 floors building shall not be lower than IV-level specified in current national standard "Graduation of Air Permeability and Their Test Method for Windows" GB7107; for 7~30 floors building, it shall not be lower than III-level specified in the above standard. 5.1.1 On condition that the room is naturally ventilated, the highest temperature of the internal surface of the building roof and the east, west external wall shall meet the following formula’s requirements: θi•max≤te•max (5.1.1) 6.1.2 During the heating period, the allowable weight humidity increment of insulation materials of the fender structure increased by interior condensation and wetting shall be in accordance with those specified in Table 6.1.2. Table 6.1.2 Allowable Weight Humidity Increment of Insulation Materials during the Heating Period [△ω (%)] ... ... ... ... 2.2 Daylighting and IIIumination GB 50033-2013 Standard for daylighting design of buildings 4.0.1 The direct natural lighting shall be provided in the bedroom, living room (hall) and kitchen of the residential building. 4.0.2 The daylighting in the bedroom and living room (hall) of the residential building shall not be less than standard value for daylighting Grade IV, and the daylighting factor of side daylighting shall not be less than 2.0%. The internal natural illuminance shall not be less than 300 lx. 4.0.4 The daylighting in the common classroom of educational building shall not be less than standard value for daylighting Grade III, the daylighting factor of side daylighting shall not be less than 3.0%, and the internal natural illuminance shall not be less than 450 lx. 4.0.6 The daylighting in the common ward of medical building shall not be less than standard value for daylighting Grade IV, the daylighting factor side daylighting shall not be less than 2.0%, and the internal natural illuminance shall not be less than 300 lx. JGJ 39-87 Code for Design of Nursery and Kindergarten Buildings 4.3.3 The average illuminance standards of main rooms in nursery and kindergarten buildings shall not be less than those specified in Table 4.3.3. Table 4.3.3 Average Illuminance Standards (lx) of Main Rooms ... ... ... ... 2.3 Sound insulation GB 50118-2010 Code for design of sound insulation of civil buildings 4.1.1 Noise level in the bedroom and living room (hall) shall be in accordance with those specified in Table 4.1.1.
Code of China
Standard
(Building Part)2013  Compulsory Provisions of Engineering Construction Standards (Building Part) 2013 (English Version)
Standard No.(Building Part)2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count260000 words
Price(USD)2100.0
Implemented on
Deliveryvia email in 1 business day
Detail of (Building Part)2013
Standard No.
(Building Part)2013
English Name
Compulsory Provisions of Engineering Construction Standards (Building Part) 2013
Chinese Name
工程建设标准强制性条文(房屋建筑部分) 2013
Chinese Classification
Professional Classification
(B
ICS Classification
Issued by
MOHURD
Issued on
Implemented on
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
260000 words
Price(USD)
2100.0
Keywords
(Building Part)2013, (Building/T Part)2013, (BuildingT Part)2013, (BuildingPart)2013, (Building/TPart)2013, (BuildingTPart)2013,
Introduction of (Building Part)2013
1 Basic Requirements GB 50352-2005 Code for design of civil buildings 4.2.1 The buildings and the attached facilities must not be constructed which extrude the boundary line of roads and filed, the architectural outshoot that can not extrude are: ----Underground building and attached facilities, including structural retaining pile, retaining wall, basement, bottom plate and its foundation of basement, cesspool and so on; ----Up-ground building and attached facilities, including porch, corridor, balcony, outdoor stair, step, ramp, flower pool, enclosure, platform, apron open sewer, air inlet and outlet of basement, passageway of basement, inlet well, light well and so on; ----Other facilities except connecting the city’s municipal public facilities like pipelines, funnels, over bridges and so on in the site. 6.6.3 Protective railing shall be set for such free positions as balcony, side corridor, indoor circular corridor, interior courtyard, person bearing roof and outdoor stair, and comply with 1 Railing shall be fabricated by firm and perdurable materials, and able to bear horizontal load prescribed in load specifications; 4 Structures preventing children climbing must be adopted for railings in residences, nursery, kindergarten, primary/secondary school and special places for children, and clear distance between railings shall be no more than 0.11m when vertical rail is adopted; 6.7.2 Except for complying with regulations of fire prevention code, horizontal distance between wall surface and center line of railing or between railings, namely width of stair horse, for daily major traffic shall be determined by the number of pedestrian flow of 0.55+(0-0.15)m, and the number shall be no less than two. 0~0.15m is oscillation amplitude of human body in marching pedestrian flow, and upper limit value shall be taken for public buildings with crowd pedestrian flow. 6.7.9 Measures to prevent children from climbing and sliding must be adopted for stairs in nursery, kindergarten, primary/secondary school and special places for children when clear width of stair well exceeds 0.20m,and structures hard to climb shall be adopted for railing of stair, Clear distance between railings shall be no more than 0.11m when vertical rail is adopted; 6.12.5 For the room used as storage of food, foodstuff, seed or drugs, it is forbidden to use toxic materials as flooring when stored materials directly contacted with flooring, and the toxicity of materials shall be identified by relevant hygiene and disease control departments. Flooring materials with foreign flavor emitting shall not be adopted for stored food with strong flavor adsorption ability. 6.14.1 Pipe shaft, smoke flue, air relief shaft and garbage shaft shall be independently set and mustn’t be incorporated in one pipe system. In addition, they shall be fabricated by non-combustible materials. 2 Indoor Environment 2.1 Thermopower GB 50176-93 Thermal design code for civil building 3.2.5 Fender structures like external wall, roof and floor slab directly contact the outside air, or the partition of staircase without heating shall be calculated with thermal insulation, and its heat transfer resistance shall be greater than or equal to the minimum heat transfer resistance required by the building-based region. 4.3.1 The internal surface temperature of the thermal bridge part of the fender structure shall not be lower than the dew-point temperature of the indoor air. 4.4.4 The air tightness of the external window of the residential building and public buildings shall be in accordance with the following requirements: 1. in region with outdoor average wind velocity in winter of greater than or equal to 3.0m/s, the 1~6 floors building shall not be lower than III-level specified in current national standard "Graduation of Air Permeability and Their Test Method for Windows" GB7107; for 7~30 floors building, it shall not be lower than II-level specified in the above standard. 1. in region with outdoor average wind velocity in winter of less than 3.0m/s, the 1~6 floors building shall not be lower than IV-level specified in current national standard "Graduation of Air Permeability and Their Test Method for Windows" GB7107; for 7~30 floors building, it shall not be lower than III-level specified in the above standard. 5.1.1 On condition that the room is naturally ventilated, the highest temperature of the internal surface of the building roof and the east, west external wall shall meet the following formula’s requirements: θi•max≤te•max (5.1.1) 6.1.2 During the heating period, the allowable weight humidity increment of insulation materials of the fender structure increased by interior condensation and wetting shall be in accordance with those specified in Table 6.1.2. Table 6.1.2 Allowable Weight Humidity Increment of Insulation Materials during the Heating Period [△ω (%)] ... ... ... ... 2.2 Daylighting and IIIumination GB 50033-2013 Standard for daylighting design of buildings 4.0.1 The direct natural lighting shall be provided in the bedroom, living room (hall) and kitchen of the residential building. 4.0.2 The daylighting in the bedroom and living room (hall) of the residential building shall not be less than standard value for daylighting Grade IV, and the daylighting factor of side daylighting shall not be less than 2.0%. The internal natural illuminance shall not be less than 300 lx. 4.0.4 The daylighting in the common classroom of educational building shall not be less than standard value for daylighting Grade III, the daylighting factor of side daylighting shall not be less than 3.0%, and the internal natural illuminance shall not be less than 450 lx. 4.0.6 The daylighting in the common ward of medical building shall not be less than standard value for daylighting Grade IV, the daylighting factor side daylighting shall not be less than 2.0%, and the internal natural illuminance shall not be less than 300 lx. JGJ 39-87 Code for Design of Nursery and Kindergarten Buildings 4.3.3 The average illuminance standards of main rooms in nursery and kindergarten buildings shall not be less than those specified in Table 4.3.3. Table 4.3.3 Average Illuminance Standards (lx) of Main Rooms ... ... ... ... 2.3 Sound insulation GB 50118-2010 Code for design of sound insulation of civil buildings 4.1.1 Noise level in the bedroom and living room (hall) shall be in accordance with those specified in Table 4.1.1.
Contents of (Building Part)2013
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
(Building Part)2013, (Building/T Part)2013, (BuildingT Part)2013, (BuildingPart)2013, (Building/TPart)2013, (BuildingTPart)2013,