2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/CECS 394-2015
CECS 394-2015   Technical specification for heptafluoropropane foam extingushing system (English Version)
Standard No.: CECS 394-2015 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 21000 words Translation Price(USD):630.0 remind me the price change

Email:

Implemented on:2015-5-1 Delivery: via email in 1 business day

→ → →

,,2015-5-1,4D07700A8A1C9C4D1468578678461
Standard No.: CECS 394-2015
English Name: Technical specification for heptafluoropropane foam extingushing system
Chinese Name: 七氟丙烷泡沫灭火系统技术规程
Professional Classification: CECS    Engineering Construction Standard
Source Content Issued by: CECS
Issued on: 2015-02-10
Implemented on: 2015-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 21000 words
Translation Price(USD): 630.0
Delivery: via email in 1 business day
1 General provisions 1.0.1 This specification is formulated in order to reasonably design the heptafluoropropane foam extinguishing system, thus ensuring its construction quality and use function, reducing fire hazards and protecting personal and property safety. 1.0.2 This specification is applicable to the heptafluoropropane foam extinguishing system installed in vertical flammable liquid storage tanks. 1.0.3 In addition to this specification, the design, construction, acceptance, maintenance and management of heptafluoropropane foam extinguishing system shall also meet the requirements of current relevant national standards. 2 Terms and symbols 2.1 Terms 2.1.1 heptafluoropropane foam extinguishing system extinguishing system which is composed of water supply system, foam concentrate storage tank, heptafluoropropane storage device and its starting device, foam proportioning set, heptafluoropropane proportioning set, heptafluoropropane foam maker, valve, pipeline, etc. and which is able to produce heptafluoropropane foam 2.1.2 heptafluoropropane proportioning set set for mixing liquid heptafluoropropane and foam solution at a specified concentration 2.1.3 heptafluoropropane foam solution solution prepared from liquid heptafluoropropane and foam solution at a specific ratio 2.1.4 heptafluoropropane concentration volume percentage of liquid heptafluoropropane in heptafluoropropane foam solution 2.1.5 heptafluoropropane foam maker device for foaming and producing heptafluoropropane foam by gasification of liquid heptafluoropropane in heptafluoropropane foam solution 2.2 Symbols C——heptafluoropropane concentration; K——margin coefficient; k——flow characteristic coefficient of heptafluoropropane foam maker; Nc——quantity of heptafluoropropane storage vessels required for the system; P——inlet pressure of heptafluoropropane foam maker; Pc——storage pressure of heptafluoropropane storage vessel; Pcs——residual pressure of heptafluoropropane storage vessel; q——flow of heptafluoropropane foam solution for heptafluoropropane foam maker; Vc——volume of a single heptafluoropropane storage vessel; Vcs——residual amount of liquid heptafluoropropane in a single storage vessel; Vjs——residual amount of liquid in the header pipe of heptafluoropropane storage device; Vq——design consumption of liquid heptafluoropropane; V0——design consumption of heptafluoropropane foam solution. 3 Extinguishing agent and system components 3.1 Selection and storage of extinguishing agent 3.1.1 For the foam concentrate, the extinguishing performance shall be of Grade I or Grade AR I, and the burn resistance shall be of Grade A. 3.1.2 When extinguishing water-soluble liquid fire or using a system to protect water-soluble and water-insoluble liquid storage tanks at the same time, anti-soluble foam concentrate must be selected. 3.1.3 The heptafluoropropane extinguishing agent shall comply with the current national standard GB 18614 Fire extinguishing agent heptafluoropropane (HFC227ea). 3.1.4 The heptafluoropropane concentration shall not be less than 5%. 3.1.5 The heptafluoropropane storage device should be set in a ventilated and dry room at 0~50℃, and the distance between the wall and the protected storage tank shall not be less than 30m.
Foreword i 1 General provisions 2 Terms and symbols 2.1 Terms 2.2 Symbols 3 Extinguishing agent and system components 3.1 Selection and storage of extinguishing agent 3.2 System components 4 Design 5 Construction 5.1 General requirements 5.2 Admission inspection 5.3 Installation 5.4 Commissioning 6 Acceptance 7 Maintenance and management Annex A Division of section works, sub-section works and sub-item works Annex B Records on system construction and acceptance Annex C Records on system maintenance and management Explanation of wording in this specification List of quoted standards
Referred in CECS 394-2015:
*GB 50151-2010 Code for design of foam extinguishing systems
*GB 50263-2007 Code for Installation and Acceptance of Gas Extinguishing System
*GB 50281-2006 Code for installation and acceptance of foam extinguishing systems
*GB 50370-2005 Code for design of gas fire extinguishing systems
*GB 18614-2012 Fire extinguishing agent heptafluoropropane(HFC227ea)
Code of China
Standard
CECS 394-2015  Technical specification for heptafluoropropane foam extingushing system (English Version)
Standard No.CECS 394-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Price(USD)630.0
Implemented on2015-5-1
Deliveryvia email in 1 business day
Detail of CECS 394-2015
Standard No.
CECS 394-2015
English Name
Technical specification for heptafluoropropane foam extingushing system
Chinese Name
七氟丙烷泡沫灭火系统技术规程
Chinese Classification
Professional Classification
CECS
ICS Classification
Issued by
CECS
Issued on
2015-02-10
Implemented on
2015-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
21000 words
Price(USD)
630.0
Keywords
CECS 394-2015, CECS/T 394-2015, CECST 394-2015, CECS394-2015, CECS 394, CECS394, CECS/T394-2015, CECS/T 394, CECS/T394, CECST394-2015, CECST 394, CECST394
Introduction of CECS 394-2015
1 General provisions 1.0.1 This specification is formulated in order to reasonably design the heptafluoropropane foam extinguishing system, thus ensuring its construction quality and use function, reducing fire hazards and protecting personal and property safety. 1.0.2 This specification is applicable to the heptafluoropropane foam extinguishing system installed in vertical flammable liquid storage tanks. 1.0.3 In addition to this specification, the design, construction, acceptance, maintenance and management of heptafluoropropane foam extinguishing system shall also meet the requirements of current relevant national standards. 2 Terms and symbols 2.1 Terms 2.1.1 heptafluoropropane foam extinguishing system extinguishing system which is composed of water supply system, foam concentrate storage tank, heptafluoropropane storage device and its starting device, foam proportioning set, heptafluoropropane proportioning set, heptafluoropropane foam maker, valve, pipeline, etc. and which is able to produce heptafluoropropane foam 2.1.2 heptafluoropropane proportioning set set for mixing liquid heptafluoropropane and foam solution at a specified concentration 2.1.3 heptafluoropropane foam solution solution prepared from liquid heptafluoropropane and foam solution at a specific ratio 2.1.4 heptafluoropropane concentration volume percentage of liquid heptafluoropropane in heptafluoropropane foam solution 2.1.5 heptafluoropropane foam maker device for foaming and producing heptafluoropropane foam by gasification of liquid heptafluoropropane in heptafluoropropane foam solution 2.2 Symbols C——heptafluoropropane concentration; K——margin coefficient; k——flow characteristic coefficient of heptafluoropropane foam maker; Nc——quantity of heptafluoropropane storage vessels required for the system; P——inlet pressure of heptafluoropropane foam maker; Pc——storage pressure of heptafluoropropane storage vessel; Pcs——residual pressure of heptafluoropropane storage vessel; q——flow of heptafluoropropane foam solution for heptafluoropropane foam maker; Vc——volume of a single heptafluoropropane storage vessel; Vcs——residual amount of liquid heptafluoropropane in a single storage vessel; Vjs——residual amount of liquid in the header pipe of heptafluoropropane storage device; Vq——design consumption of liquid heptafluoropropane; V0——design consumption of heptafluoropropane foam solution. 3 Extinguishing agent and system components 3.1 Selection and storage of extinguishing agent 3.1.1 For the foam concentrate, the extinguishing performance shall be of Grade I or Grade AR I, and the burn resistance shall be of Grade A. 3.1.2 When extinguishing water-soluble liquid fire or using a system to protect water-soluble and water-insoluble liquid storage tanks at the same time, anti-soluble foam concentrate must be selected. 3.1.3 The heptafluoropropane extinguishing agent shall comply with the current national standard GB 18614 Fire extinguishing agent heptafluoropropane (HFC227ea). 3.1.4 The heptafluoropropane concentration shall not be less than 5%. 3.1.5 The heptafluoropropane storage device should be set in a ventilated and dry room at 0~50℃, and the distance between the wall and the protected storage tank shall not be less than 30m.
Contents of CECS 394-2015
Foreword i 1 General provisions 2 Terms and symbols 2.1 Terms 2.2 Symbols 3 Extinguishing agent and system components 3.1 Selection and storage of extinguishing agent 3.2 System components 4 Design 5 Construction 5.1 General requirements 5.2 Admission inspection 5.3 Installation 5.4 Commissioning 6 Acceptance 7 Maintenance and management Annex A Division of section works, sub-section works and sub-item works Annex B Records on system construction and acceptance Annex C Records on system maintenance and management Explanation of wording in this specification List of quoted standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
CECS 394-2015, CECS/T 394-2015, CECST 394-2015, CECS394-2015, CECS 394, CECS394, CECS/T394-2015, CECS/T 394, CECS/T394, CECST394-2015, CECST 394, CECST394