2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/CJJ 110-2006
CJJ 110-2006   Technical specification of pipe system for fine drinking water (English Version)
Standard No.: CJJ 110-2006 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2008-8-1 Delivery: via email in 1 business day

→ → →

2017-11-1,2017-11-1,2008-8-1,141137481204430DE38EAF5A2B9EE
Standard No.: CJJ 110-2006
English Name: Technical specification of pipe system for fine drinking water
Chinese Name: 管道直饮水系统技术规程
Chinese Classification: Q81    Water supply and draining instrument and equipment
Professional Classification: CJ    Professional Standard - Urban Construction
ICS Classification: 91.140.60 91.140.60    Water supply systems 91.140.60
Source Content Issued by: MOHURD
Issued on: 2008-2-29
Implemented on: 2008-8-1
Status: superseded
Superseded by:CJJ/T 110-2017 Technical specification of pipe system for fine drinking water in building and sub-district
Superseded on:2017-11-1
Abolished on:2017-11-1
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This specification is formulated to ensure the quality, amount and pressure of fine drinking water supplied by pipe system, and to make the system hygienic and safe, technology-advanced, economic and rational. 1.0.2 This specification is applicable to the design, construction, acceptance, operation and management of pipe system for fine drinking water in residential building, public building, etc. 1.0.3 Pipings and pipe fittings, equipment and auxiliary materials adopted for pipe system for fine drinking water shall meet the requirements of current relevant national standards, and the hygienic performance shall meet the requirements of the current national standard ""Standard for Safety Evaluation of Equipment and Protective Materials in Drinking Water System"" (GB/T 17219). 1.0.4 The design, construction, acceptance, operation and management of pipe system for fine drinking water shall not only meet the requirements of this specification, but also comply with those stipulated in the current relevant national standards. 2 Terms and Symbols 2.1 Terms 2.1.1 Pipe system for fine drinking water The water supply system supplying fine drinking water for people after the raw water is subject to advanced water treatment and meets the standard. 2.1.2 Raw water Domestic drinking water without advanced water treatment or any water with quality similar to that of domestic drinking water. 2.1.3 Product water The fine drinking water (supplied for the user) which is processed with raw water through centralized treatment such as advanced water treatment and disinfection. 2.1.4 Instantaneous peak flow rate The average flow rate of the specified time interval within the most intensive water consumption period. 2.1.5 Tab use probability The ratio of the discharge time within the time interval from the first water discharge to the start of the second water discharge in two adjacent water uses during the peak water consumption period. 2.1.6 Circulating flow The circulating water flow in the circulation system, of which, the value is determined according to the operation system and circulating time of the system. 2.1.7 Advanced water treatment The further treatment process of raw water, which is capable of removing organic pollutants (including the substances that may lead to carcinogenesis, teratogenesis and mutagenesis, disinfection by-products), heavy metal, bacteria, virus, other pathogenic microorganism and pathogen protozoan. 2.1.8 Kinetic degradation fluxion process The high-purity copper and zinc alloy filter material, which may, through electrochemical oxidation-reduction reaction after being exposed to water, effectively reduce or remove the chlorine and heavy metal in water and restrain the growing and reproduction of microorganisms in water. 2.1.9 Silt density index (SDI) The value expressing the concentration and filtration characteristics of suspended solids and colloidal matters in inflow water. 2.2 Symbols 2.2.1 Flow rate Qb - the design flow rate of water pump; Qd - the maximum daily fine drinking water amount of the system; Qj - the water yield of water purification equipment; qd - the maximum daily fine drinking water quota; q0 - the rated flow rate of tab; qs - the instantaneous peak flow rate; qx - the circulating flow. 2.2.2 Water pressure and head loss ∑h - the total head loss of pipeline from the most unfavorable tab to water purifying box (tank); h0 - the minimum working pressure; Hb - the rated lift of water pump. 2.2.3 Geometrical characteristics V - the total volume of water supply and return system in closed circulation loop; Vj - the effective volume of water purifying box (tank); Vy - the volume of raw water regulating box (tank); Z - the geometric height difference between the most unfavorable tab and the lowest water level of water purifying box (tank). 2.2.4 Calculation coefficient k - the intermediate variable; ki - the empirical coefficient of volume; m - the tab use number during instantaneous peak water consumption; N - the number of people served by system; n - the number of tabs; ne - the converted number of tabs; p - the tab use probability; pe - the new computational probability; Pn - the simultaneous water consumption probability with the number of tabs not larger than m; T1 - the circulating time; T2 - the maximum daily design accumulated working time of water purification equipment; α - the empirical coefficient.
Contents Foreword I 1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Water Quality, Amount and Pressure 4 Water Treatment 5 System Design 6 System Calculation and Equipment Selection 7 Water Purifying Machine Room 8 Water Quality Inspection 9 Control System 10 Construction and Installation 10.1 General Requirements 10.2 Pipe Laying 10.3 Equipment Installation 10.4 Construction Safety 11 Work Acceptance 11.1 Pipe Pressure Test 11.2 Cleaning and Disinfection 11.3 Acceptance 12 Operating Maintenance and Management 12.1 General Requirements 12.2 Outdoor Pipe Network and Facility Maintenance 12.3 Indoor Pipe Maintenance 12.4 Operation Management Explanation of Wording in This Specification
Code of China
Standard
CJJ 110-2006  Technical specification of pipe system for fine drinking water (English Version)
Standard No.CJJ 110-2006
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2008-8-1
Deliveryvia email in 1 business day
Detail of CJJ 110-2006
Standard No.
CJJ 110-2006
English Name
Technical specification of pipe system for fine drinking water
Chinese Name
管道直饮水系统技术规程
Chinese Classification
Q81
Professional Classification
CJ
ICS Classification
Issued by
MOHURD
Issued on
2008-2-29
Implemented on
2008-8-1
Status
superseded
Superseded by
CJJ/T 110-2017 Technical specification of pipe system for fine drinking water in building and sub-district
Superseded on
2017-11-1
Abolished on
2017-11-1
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
CJJ 110-2006, CJJ/T 110-2006, CJJT 110-2006, CJJ110-2006, CJJ 110, CJJ110, CJJ/T110-2006, CJJ/T 110, CJJ/T110, CJJT110-2006, CJJT 110, CJJT110
Introduction of CJJ 110-2006
1 General Provisions 1.0.1 This specification is formulated to ensure the quality, amount and pressure of fine drinking water supplied by pipe system, and to make the system hygienic and safe, technology-advanced, economic and rational. 1.0.2 This specification is applicable to the design, construction, acceptance, operation and management of pipe system for fine drinking water in residential building, public building, etc. 1.0.3 Pipings and pipe fittings, equipment and auxiliary materials adopted for pipe system for fine drinking water shall meet the requirements of current relevant national standards, and the hygienic performance shall meet the requirements of the current national standard ""Standard for Safety Evaluation of Equipment and Protective Materials in Drinking Water System"" (GB/T 17219). 1.0.4 The design, construction, acceptance, operation and management of pipe system for fine drinking water shall not only meet the requirements of this specification, but also comply with those stipulated in the current relevant national standards. 2 Terms and Symbols 2.1 Terms 2.1.1 Pipe system for fine drinking water The water supply system supplying fine drinking water for people after the raw water is subject to advanced water treatment and meets the standard. 2.1.2 Raw water Domestic drinking water without advanced water treatment or any water with quality similar to that of domestic drinking water. 2.1.3 Product water The fine drinking water (supplied for the user) which is processed with raw water through centralized treatment such as advanced water treatment and disinfection. 2.1.4 Instantaneous peak flow rate The average flow rate of the specified time interval within the most intensive water consumption period. 2.1.5 Tab use probability The ratio of the discharge time within the time interval from the first water discharge to the start of the second water discharge in two adjacent water uses during the peak water consumption period. 2.1.6 Circulating flow The circulating water flow in the circulation system, of which, the value is determined according to the operation system and circulating time of the system. 2.1.7 Advanced water treatment The further treatment process of raw water, which is capable of removing organic pollutants (including the substances that may lead to carcinogenesis, teratogenesis and mutagenesis, disinfection by-products), heavy metal, bacteria, virus, other pathogenic microorganism and pathogen protozoan. 2.1.8 Kinetic degradation fluxion process The high-purity copper and zinc alloy filter material, which may, through electrochemical oxidation-reduction reaction after being exposed to water, effectively reduce or remove the chlorine and heavy metal in water and restrain the growing and reproduction of microorganisms in water. 2.1.9 Silt density index (SDI) The value expressing the concentration and filtration characteristics of suspended solids and colloidal matters in inflow water. 2.2 Symbols 2.2.1 Flow rate Qb - the design flow rate of water pump; Qd - the maximum daily fine drinking water amount of the system; Qj - the water yield of water purification equipment; qd - the maximum daily fine drinking water quota; q0 - the rated flow rate of tab; qs - the instantaneous peak flow rate; qx - the circulating flow. 2.2.2 Water pressure and head loss ∑h - the total head loss of pipeline from the most unfavorable tab to water purifying box (tank); h0 - the minimum working pressure; Hb - the rated lift of water pump. 2.2.3 Geometrical characteristics V - the total volume of water supply and return system in closed circulation loop; Vj - the effective volume of water purifying box (tank); Vy - the volume of raw water regulating box (tank); Z - the geometric height difference between the most unfavorable tab and the lowest water level of water purifying box (tank). 2.2.4 Calculation coefficient k - the intermediate variable; ki - the empirical coefficient of volume; m - the tab use number during instantaneous peak water consumption; N - the number of people served by system; n - the number of tabs; ne - the converted number of tabs; p - the tab use probability; pe - the new computational probability; Pn - the simultaneous water consumption probability with the number of tabs not larger than m; T1 - the circulating time; T2 - the maximum daily design accumulated working time of water purification equipment; α - the empirical coefficient.
Contents of CJJ 110-2006
Contents Foreword I 1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Water Quality, Amount and Pressure 4 Water Treatment 5 System Design 6 System Calculation and Equipment Selection 7 Water Purifying Machine Room 8 Water Quality Inspection 9 Control System 10 Construction and Installation 10.1 General Requirements 10.2 Pipe Laying 10.3 Equipment Installation 10.4 Construction Safety 11 Work Acceptance 11.1 Pipe Pressure Test 11.2 Cleaning and Disinfection 11.3 Acceptance 12 Operating Maintenance and Management 12.1 General Requirements 12.2 Outdoor Pipe Network and Facility Maintenance 12.3 Indoor Pipe Maintenance 12.4 Operation Management Explanation of Wording in This Specification