2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/CJ/T 395-2012
CJ/T 395-2012   Gas-fired heating and hot water condensing combi-boilers (English Version)
Standard No.: CJ/T 395-2012 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2012-8-1 Delivery: via email in 1 business day

→ → →

,,2012-8-1,14113778317660BE8748D9006A83C
Standard No.: CJ/T 395-2012
English Name: Gas-fired heating and hot water condensing combi-boilers
Chinese Name: 冷凝式燃气暖浴两用炉
Professional Classification: CJ    Professional Standard - Urban Construction
Source Content Issued by: MOC
Issued on: 2012-02-29
Implemented on: 2012-8-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
This standard specifies the terms and definitions, classification and model, requirements for material, structure and safety, performance requirements, test method, inspection rules, marking, precaution and instruction as well as packing, transport and storage with regards to the gas-fired heating and hot water condensing combi-boilers (hereinafter referred to as "condensing boilers"). This standard is applicable to such condensing boilers: nominal heat input is not greater than 70kW; maximum heating operating water pressure is not greater than 0.3MPa; the water temperature is not greater than 95℃ in the operation; the blower atmospheric burner or full premix burner is adopted. The condensing boilers with nominal heat input greater than 70 kW may refer to this standard. This standard is applicable to the heating and hot water or heating condensing boilers. This standard is applicable to the condensing boilers fired by natural gas, liquefied petroleum gas and manufactured gas in conformity with those specified in GB/T 13611. This standard is not applicable to condensing boilers of the following types: ——Natural draught flue type and natural draught balance type; ——Outdoor type; ——Positive displacement; ——Condensing boilers adopting two sets of independent combustion systems respectively for heating and hot water in the same enclosure, including the boilers with common flue.
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Model 5 Material, Structure and Safety 6 Requirements 7 Test Method 8 Inspection Rules 9 Marking, Precaution and Instructions 10 Packing, Transport and Storage Appendix A (Informative) Structural Changes between this Standard and EN 677:1998 Appendix B (Informative) Technical Differences between this Standard and EN 677:1998 and their Reasons Appendix C (Normative) Correction for the Determined Efficiency in the Low Water Temperature Test of Condensing Boilers Appendix D (Informative) Clauses Number of this Standard Addressing Basic Requirements in GB 16914-2003
Referred in CJ/T 395-2012:
* GB/T 13611-2006 Classification and essential property of city gas
* GB 25034-2010 Gas-fired heating and hot water combi-boilers
* GB/T 2828.1-2003 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
CJ/T 395-2012 is referred in:
* GB 20665-2015 Minimum allowable values of energy efficiency and energy efficiency grades for domestic gas instantaneous water heaters and gas fired heating and hot water combi-boilers
Code of China
Standard
CJ/T 395-2012  Gas-fired heating and hot water condensing combi-boilers (English Version)
Standard No.CJ/T 395-2012
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)120.0
Implemented on2012-8-1
Deliveryvia email in 1 business day
Detail of CJ/T 395-2012
Standard No.
CJ/T 395-2012
English Name
Gas-fired heating and hot water condensing combi-boilers
Chinese Name
冷凝式燃气暖浴两用炉
Chinese Classification
Professional Classification
CJ
ICS Classification
Issued by
MOC
Issued on
2012-02-29
Implemented on
2012-8-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
120.0
Keywords
CJ/T 395-2012, CJ 395-2012, CJT 395-2012, CJ/T395-2012, CJ/T 395, CJ/T395, CJ395-2012, CJ 395, CJ395, CJT395-2012, CJT 395, CJT395
Introduction of CJ/T 395-2012
This standard specifies the terms and definitions, classification and model, requirements for material, structure and safety, performance requirements, test method, inspection rules, marking, precaution and instruction as well as packing, transport and storage with regards to the gas-fired heating and hot water condensing combi-boilers (hereinafter referred to as "condensing boilers"). This standard is applicable to such condensing boilers: nominal heat input is not greater than 70kW; maximum heating operating water pressure is not greater than 0.3MPa; the water temperature is not greater than 95℃ in the operation; the blower atmospheric burner or full premix burner is adopted. The condensing boilers with nominal heat input greater than 70 kW may refer to this standard. This standard is applicable to the heating and hot water or heating condensing boilers. This standard is applicable to the condensing boilers fired by natural gas, liquefied petroleum gas and manufactured gas in conformity with those specified in GB/T 13611. This standard is not applicable to condensing boilers of the following types: ——Natural draught flue type and natural draught balance type; ——Outdoor type; ——Positive displacement; ——Condensing boilers adopting two sets of independent combustion systems respectively for heating and hot water in the same enclosure, including the boilers with common flue.
Contents of CJ/T 395-2012
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Model 5 Material, Structure and Safety 6 Requirements 7 Test Method 8 Inspection Rules 9 Marking, Precaution and Instructions 10 Packing, Transport and Storage Appendix A (Informative) Structural Changes between this Standard and EN 677:1998 Appendix B (Informative) Technical Differences between this Standard and EN 677:1998 and their Reasons Appendix C (Normative) Correction for the Determined Efficiency in the Low Water Temperature Test of Condensing Boilers Appendix D (Informative) Clauses Number of this Standard Addressing Basic Requirements in GB 16914-2003
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
CJ/T 395-2012, CJ 395-2012, CJT 395-2012, CJ/T395-2012, CJ/T 395, CJ/T395, CJ395-2012, CJ 395, CJ395, CJT395-2012, CJT 395, CJT395