2025-12-28 10.8.118.215
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 1979-2019
DL/T 1979-2019   Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant (English Version)
Standard No.: DL/T 1979-2019 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3500 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2019-10-1 Delivery: via email in 1 business day

→ → →

,,2019-10-1,F24A801E5C0F09371561735578575
Standard No.: DL/T 1979-2019
English Name: Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant
Chinese Name: 电力用磷酸酯抗燃油中矿物油含量测定法
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: NEA
Issued on: 2019-06-04
Implemented on: 2019-10-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 3500 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant 1 Scope This standard specifies the summary of test methods, apparatuses and materials, test procedures, calculation, precision, reported value, etc. for the determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant. This standard is applicable to determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods 3 Summary of test methods Add alkali liquor to a certain amount of samples to completely saponify phosphate ester, extract mineral oil in samples with petroleum ether, transfer the extracted liquid to a beaker with constant weight, steam petroleum ether and weigh the total weight of beaker and mineral oil in it again, and the difference between the two weighing is the content of mineral oil in samples, and the result is expressed by mass percentage. 4 Apparatus and materials 4.1 Potassium hydroxide: analytically pure; 4.2 Petroleum ether: analytically pure, with a boiling range of 60°C to 90°C. 4.3 Water: shall meet the requirements for Grade 3 water as specified in GB/T 6682. 4.4 Flask: 500 mL. 4.5 Beaker: 150 mL. 4.6 Pipette: 50 mL. 4.7 Separating funnel: 250 mL. 4.8 Spherical or straight reflux condenser: about 300 mm long. 4.9 Electric plate: adjustable, with working temperature not greater than 100 °C. 4.10 Electric jacket: adjustable, 500 mL, with the maximum service temperature of 380 °C. 4.11 Desiccator. 4.12 Balance: with a sensibility of 0.1 g or 0.1 mg. 4.13 Zeolite: Porcelain tube or glass bead. 5 Test procedures
Foreword i 1 Scope 2 Normative references 3 Summary of test methods 4 Apparatus and materials 5 Test procedures 6 Calculation 7 Precision 8 Reported values
Referred in DL/T 1979-2019:
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
Code of China
Standard
DL/T 1979-2019  Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant (English Version)
Standard No.DL/T 1979-2019
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3500 words
Price(USD)100.0
Implemented on2019-10-1
Deliveryvia email in 1 business day
Detail of DL/T 1979-2019
Standard No.
DL/T 1979-2019
English Name
Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant
Chinese Name
电力用磷酸酯抗燃油中矿物油含量测定法
Chinese Classification
Professional Classification
DL
ICS Classification
Issued by
NEA
Issued on
2019-06-04
Implemented on
2019-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
3500 words
Price(USD)
100.0
Keywords
DL/T 1979-2019, DL 1979-2019, DLT 1979-2019, DL/T1979-2019, DL/T 1979, DL/T1979, DL1979-2019, DL 1979, DL1979, DLT1979-2019, DLT 1979, DLT1979
Introduction of DL/T 1979-2019
Determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant 1 Scope This standard specifies the summary of test methods, apparatuses and materials, test procedures, calculation, precision, reported value, etc. for the determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant. This standard is applicable to determination of mineral oil content in phosphate ester fire-resistant fluid used in power plant. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods 3 Summary of test methods Add alkali liquor to a certain amount of samples to completely saponify phosphate ester, extract mineral oil in samples with petroleum ether, transfer the extracted liquid to a beaker with constant weight, steam petroleum ether and weigh the total weight of beaker and mineral oil in it again, and the difference between the two weighing is the content of mineral oil in samples, and the result is expressed by mass percentage. 4 Apparatus and materials 4.1 Potassium hydroxide: analytically pure; 4.2 Petroleum ether: analytically pure, with a boiling range of 60°C to 90°C. 4.3 Water: shall meet the requirements for Grade 3 water as specified in GB/T 6682. 4.4 Flask: 500 mL. 4.5 Beaker: 150 mL. 4.6 Pipette: 50 mL. 4.7 Separating funnel: 250 mL. 4.8 Spherical or straight reflux condenser: about 300 mm long. 4.9 Electric plate: adjustable, with working temperature not greater than 100 °C. 4.10 Electric jacket: adjustable, 500 mL, with the maximum service temperature of 380 °C. 4.11 Desiccator. 4.12 Balance: with a sensibility of 0.1 g or 0.1 mg. 4.13 Zeolite: Porcelain tube or glass bead. 5 Test procedures
Contents of DL/T 1979-2019
Foreword i 1 Scope 2 Normative references 3 Summary of test methods 4 Apparatus and materials 5 Test procedures 6 Calculation 7 Precision 8 Reported values