1. Scope
This Code specifies that the design of ash handling system of large-scale thermal power plant shall abide by the principle and construction standard.
This Code is applicable to the ash handling design of condensing power plant in output of 125MW or above of the turbo generator unit, and also applicable to the ash handling design of 50MW or above heating unit thermal plant and power station with clean coal power generation technology.
This Code is applicable to the ash handling design of newly-built or extended power plant, while the ash handling design of the reconstructed project may refer to this code.
2. Normative References
The following standards contain provisions which, through reference in this text, constitute provisions of this Standard. For dated reference, subsequent amendments (excluding content of corrigenda) to, or revisions of, any of these publications do not apply. However, Parties to agreements based on this Code are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document referred to applies.
Standard
DL/T 5142-2002 Code for Designing Ash Handling System of Power Plant (English Version)
Standard No.
DL/T 5142-2002
Status
superseded
Language
English
File Format
PDF
Word Count
19000 words
Price(USD)
470.0
Implemented on
2002-9-1
Delivery
via email in 1 business day
Detail of DL/T 5142-2002
Standard No.
DL/T 5142-2002
English Name
Code for Designing Ash Handling System of Power Plant
1. Scope
This Code specifies that the design of ash handling system of large-scale thermal power plant shall abide by the principle and construction standard.
This Code is applicable to the ash handling design of condensing power plant in output of 125MW or above of the turbo generator unit, and also applicable to the ash handling design of 50MW or above heating unit thermal plant and power station with clean coal power generation technology.
This Code is applicable to the ash handling design of newly-built or extended power plant, while the ash handling design of the reconstructed project may refer to this code.
2. Normative References
The following standards contain provisions which, through reference in this text, constitute provisions of this Standard. For dated reference, subsequent amendments (excluding content of corrigenda) to, or revisions of, any of these publications do not apply. However, Parties to agreements based on this Code are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document referred to applies.