2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/DL/T 639-1997
DL/T 639-1997   Safety and Protection Rules for Operation, Test and Maintenance Personnel of SF6 in Electrical Apparatus (English Version)
Standard No.: DL/T 639-1997 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):294.0 remind me the price change

Email:

Implemented on:1998-1-1 Delivery: via email in 1 business day

→ → →

2016-06-01,2016-6-1,1998-1-1,14113731972064EC93ED4739B536B
Standard No.: DL/T 639-1997
English Name: Safety and Protection Rules for Operation, Test and Maintenance Personnel of SF6 in Electrical Apparatus
Chinese Name: 六氟化硫电气设备运行、试验及检修人员安全防护细则
Chinese Classification: K60    Electrical equipment and tool in general
Professional Classification: DL    Professional Standard - Electricity
Source Content Issued by: MPI
Issued on: 1997-10-22
Implemented on: 1998-1-1
Status: superseded
Superseded by:DL/T 639-2016 Safety and protection rules for operation, test and maintenace personnel of SF6 in electrical apparatus
Superseded on:2016-6-1
Abolished on:2016-06-01
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 294.0
Delivery: via email in 1 business day
1 Subject Content and Application Scope 1.1 This standard includes the safe application of SF6 gas, the safety and protection measures during the operation and disassembly of equipment, as well as the management and application of personal protective articles, and so on. 1.2 This standard is applicable to the safety and protection of operation, test and maintenance personnel of SF6 in electrical apparatus, and the other relevant using units of SF6 electrical apparatus still can make references from this standard. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At time of publication, the editions indicated were valid. All standards are subject to revision, and parties concerned are encouraged to discuss the possibility of applying the latest edition of the following standards. GB 8905-1996 "The Guide for Processing and Measuring SF6 Gas in Power Apparatus" GB 11651-89 "Selection Rules of Articles for Labor Protection Use" GB 12022-89 "Sulphur Hexafluoride for Industrial Use" DL/T 595-1996 "Rules for Supervising SF6 Gas in Electrical Apparatus" DL/T 596-1996 "The Preventive Test Work for Electric Equipment Regulation" SD 312-89 "Biotoxication Tests by Sulphur Hexafluoride" IEC 376-1972 "Regulations for and Acceptance of New Sulphur Hexafluoride" IEC 480-1974 "Guide to Checking Sulfur Hexafluoride Taken from Electrical Equipment" 3 Terms 3.1 Sulphur hexafluoride Sulphur hexafluoride is of gas state, nontoxic, colorless, flavorless and with very stable chemical properties at normal temperature and pressure, its density is 6.16g/L and it is with outstanding insulation, arc extinguishing and electrical performances at 20℃ and 101325 Pa. 3.2 SF6 electrical apparatus It is the electrical apparatus filled with sulphur hexafluoride as the isolation medium, such as sulphur hexafluoride circuit breaker, transformer, cable and Gas Insulated Switchgears (GIS), etc. 3.3 Toxic decomposition products The production of SF6 gas is accompanied by various toxic gases which may be mixed into the gas product; SF6 gas in electrical apparatus still will produce various toxic and corrosive gases and solid decomposition products through the action of electrical corona, spark and arc discharge. These gases mainly are thionyl sulfide (SOF2), sulfuryl fluoride (SO2F2), sulfur tetrafluoride (SF4), sulphonyl tetrafluoride (SOF4), sulfur dioxide (SO2), disulfur decafluoride (S2F10) and disulfuryl decafluoride (S2F10O); the solid decomposition products mainly are copper fluoride (CuF2), dimethyl silicone difluoride [Si(CH3)2F2] and aluminum fluoride (AlF3) powder. See Appendix A for the permissible contents of toxic decomposition products in work place. 3.4 Purifying handle for SF6 gas The toxic decomposition products in SF6 gas may be absorbed with adsorbent, or may be eliminated through chemical reaction with acid solution or alkali solution, and this process of eliminating the toxic decomposition products in SF6 gas with various methods is named as purifying handle for SF6 gas.
Foreword I 1 Subject Content and Application Scope 2 Normative References 3 Terms 4 Safe Application of Sulphur Hexafluoride 5 Management and application of Safety Protection Articles 6 Organization Management and Labor Hygiene Appendix A (Normative) Permissible Contents of SF6 Gas and Its Toxic Decomposition Products in Work Place Appendix B (Normative) Quality Standards of SF6 Gas
Referred in DL/T 639-1997:
* GB 8905-1996
* GB 11651-1989 Selection rules of articles for labour protection use
* GB 12022-1989 Sulphur hexafluoride for industrial use
* DL/T 595-1996 Rules for supervising SF6 gas in electrical apparatus
* DL/T 596-1996 Preventive Test Code for Electric Power Equipment
* SD 312-1989
DL/T 639-1997 is referred in:
* DL/T 5218-2005 Technical code for designing 220kV~500kV substation
Code of China
Standard
DL/T 639-1997  Safety and Protection Rules for Operation, Test and Maintenance Personnel of SF6 in Electrical Apparatus (English Version)
Standard No.DL/T 639-1997
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)294.0
Implemented on1998-1-1
Deliveryvia email in 1 business day
Detail of DL/T 639-1997
Standard No.
DL/T 639-1997
English Name
Safety and Protection Rules for Operation, Test and Maintenance Personnel of SF6 in Electrical Apparatus
Chinese Name
六氟化硫电气设备运行、试验及检修人员安全防护细则
Chinese Classification
K60
Professional Classification
DL
ICS Classification
Issued by
MPI
Issued on
1997-10-22
Implemented on
1998-1-1
Status
superseded
Superseded by
DL/T 639-2016 Safety and protection rules for operation, test and maintenace personnel of SF6 in electrical apparatus
Superseded on
2016-6-1
Abolished on
2016-06-01
Superseding
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
294.0
Keywords
DL/T 639-1997, DL 639-1997, DLT 639-1997, DL/T639-1997, DL/T 639, DL/T639, DL639-1997, DL 639, DL639, DLT639-1997, DLT 639, DLT639
Introduction of DL/T 639-1997
1 Subject Content and Application Scope 1.1 This standard includes the safe application of SF6 gas, the safety and protection measures during the operation and disassembly of equipment, as well as the management and application of personal protective articles, and so on. 1.2 This standard is applicable to the safety and protection of operation, test and maintenance personnel of SF6 in electrical apparatus, and the other relevant using units of SF6 electrical apparatus still can make references from this standard. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. At time of publication, the editions indicated were valid. All standards are subject to revision, and parties concerned are encouraged to discuss the possibility of applying the latest edition of the following standards. GB 8905-1996 "The Guide for Processing and Measuring SF6 Gas in Power Apparatus" GB 11651-89 "Selection Rules of Articles for Labor Protection Use" GB 12022-89 "Sulphur Hexafluoride for Industrial Use" DL/T 595-1996 "Rules for Supervising SF6 Gas in Electrical Apparatus" DL/T 596-1996 "The Preventive Test Work for Electric Equipment Regulation" SD 312-89 "Biotoxication Tests by Sulphur Hexafluoride" IEC 376-1972 "Regulations for and Acceptance of New Sulphur Hexafluoride" IEC 480-1974 "Guide to Checking Sulfur Hexafluoride Taken from Electrical Equipment" 3 Terms 3.1 Sulphur hexafluoride Sulphur hexafluoride is of gas state, nontoxic, colorless, flavorless and with very stable chemical properties at normal temperature and pressure, its density is 6.16g/L and it is with outstanding insulation, arc extinguishing and electrical performances at 20℃ and 101325 Pa. 3.2 SF6 electrical apparatus It is the electrical apparatus filled with sulphur hexafluoride as the isolation medium, such as sulphur hexafluoride circuit breaker, transformer, cable and Gas Insulated Switchgears (GIS), etc. 3.3 Toxic decomposition products The production of SF6 gas is accompanied by various toxic gases which may be mixed into the gas product; SF6 gas in electrical apparatus still will produce various toxic and corrosive gases and solid decomposition products through the action of electrical corona, spark and arc discharge. These gases mainly are thionyl sulfide (SOF2), sulfuryl fluoride (SO2F2), sulfur tetrafluoride (SF4), sulphonyl tetrafluoride (SOF4), sulfur dioxide (SO2), disulfur decafluoride (S2F10) and disulfuryl decafluoride (S2F10O); the solid decomposition products mainly are copper fluoride (CuF2), dimethyl silicone difluoride [Si(CH3)2F2] and aluminum fluoride (AlF3) powder. See Appendix A for the permissible contents of toxic decomposition products in work place. 3.4 Purifying handle for SF6 gas The toxic decomposition products in SF6 gas may be absorbed with adsorbent, or may be eliminated through chemical reaction with acid solution or alkali solution, and this process of eliminating the toxic decomposition products in SF6 gas with various methods is named as purifying handle for SF6 gas.
Contents of DL/T 639-1997
Foreword I 1 Subject Content and Application Scope 2 Normative References 3 Terms 4 Safe Application of Sulphur Hexafluoride 5 Management and application of Safety Protection Articles 6 Organization Management and Labor Hygiene Appendix A (Normative) Permissible Contents of SF6 Gas and Its Toxic Decomposition Products in Work Place Appendix B (Normative) Quality Standards of SF6 Gas
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
DL/T 639-1997, DL 639-1997, DLT 639-1997, DL/T639-1997, DL/T 639, DL/T639, DL639-1997, DL 639, DL639, DLT639-1997, DLT 639, DLT639