This standard specifies the operation test requirements of Grades I, II and III electric gate valves, electric check valve, electronic throttle valve, electric ball valve, electric diaphragm valve and the like in 300MW PWR nuclear power plant.
This standard is applicable to the operation test of the above-mentioned electric valves in 300MW PWR nuclear power plant; PWR nuclear power plants using other powers may also refer to this standard.
This standard excludes other tests of the above-mentioned valves as well as the tests of other valves used in nuclear power plant.
2 Normative References
JB 2921 Technical Specifications of Electric Valve Actuators
JB 2195 Three-phase Asynchronous Motor for YDF Series Electric Valve
EJ 395 Technical Specification for Valve Electric Actuator in 300MW PWR Nuclear Power Plant
EJ 387 Technical Specifications of Cleaning in the Stage of Primary Loop System Commissioning in 300MW PWR Nuclear Power Plant
3 General Requirements
3.1 Electric actuator
The applicable electric actuator shall not be assembled with valve for inspection before it is accepted according to the requirements of EJ 395.
EJ/T 396-1989 300000KW PWR nuclear power plant - Test requirements for motor-driven valve operating test (English Version)
Standard No.
EJ/T 396-1989
Status
valid
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Implemented on
1989-10-1
Delivery
via email in 1 business day
Detail of EJ/T 396-1989
Standard No.
EJ/T 396-1989
English Name
300000KW PWR nuclear power plant - Test requirements for motor-driven valve operating test
Chinese Name
三十万千瓦压水堆核电厂 电动阀门动作试验要求
Chinese Classification
Professional Classification
EJ
ICS Classification
Issued by
Issued on
Implemented on
1989-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Keywords
EJ/T 396-1989, EJ 396-1989, EJT 396-1989, EJ/T396-1989, EJ/T 396, EJ/T396, EJ396-1989, EJ 396, EJ396, EJT396-1989, EJT 396, EJT396
Introduction of EJ/T 396-1989
1 Subject Content and Applicable Scope
This standard specifies the operation test requirements of Grades I, II and III electric gate valves, electric check valve, electronic throttle valve, electric ball valve, electric diaphragm valve and the like in 300MW PWR nuclear power plant.
This standard is applicable to the operation test of the above-mentioned electric valves in 300MW PWR nuclear power plant; PWR nuclear power plants using other powers may also refer to this standard.
This standard excludes other tests of the above-mentioned valves as well as the tests of other valves used in nuclear power plant.
2 Normative References
JB 2921 Technical Specifications of Electric Valve Actuators
JB 2195 Three-phase Asynchronous Motor for YDF Series Electric Valve
EJ 395 Technical Specification for Valve Electric Actuator in 300MW PWR Nuclear Power Plant
EJ 387 Technical Specifications of Cleaning in the Stage of Primary Loop System Commissioning in 300MW PWR Nuclear Power Plant
3 General Requirements
3.1 Electric actuator
The applicable electric actuator shall not be assembled with valve for inspection before it is accepted according to the requirements of EJ 395.