2025-12-14 10.2.82.121
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 14287.5-2025
GB 14287.5-2025   Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors (English Version)
Standard No.: GB 14287.5-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):405.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1~5 business day

→ → →

,,2026-11-1,44C66D43E2C205551762263304332
Standard No.: GB 14287.5-2025
English Name: Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors
Chinese Name: 电气火灾监控系统 第5部分:测量热解粒子式电气火灾监控探测器
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-11-1
Status: to be valid
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 405.0
Delivery: via email in 1~5 business day
GB 14287.5-2025 Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 55.200 CCS H 57 National Standard of the People's Republic of China ‌GB 14287.5-2025 Electrical fire monitoring system - Part 5: Pyrolysis sensing electrical fire monitoring detectors 电气火灾监控系统 第5部分:测量热解粒子式电气火灾监控探测器 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Preface‌ ‌Introduction‌ ‌1 Scope‌ ‌2 Normative References‌ ‌3 Terms and Definitions‌ ‌4 Classification‌ ‌5 Requirements‌ ‌5.1 General Requirements‌ ‌5.2 Appearance‌ ‌5.3 Basic Functions‌ ‌5.4 Monitoring and Alarm Functions‌ ‌5.5 Communication Functions‌ ‌5.6 Performance of Major Components‌ ‌5.7 Detection and Alarm Performance‌ ‌6 Test Methods‌ ‌6.1 General Requirements‌ ‌6.2 Basic Function Tests‌ ‌6.3 Monitoring and Alarm Function Tests‌ ‌6.4 Communication Function Tests‌ ‌6.5 Detection and Alarm Performance Tests‌ ‌6.6 Repeatability Tests‌ ‌6.7 Insulation Resistance Tests‌ ‌6.8 Leakage Current Tests‌ ‌6.9 Electrical Strength Tests‌ ‌7 Inspection Rules‌ ‌7.1 Factory Inspection‌ ‌7.2 Type Inspection‌ ‌8 Marking and Packaging‌ ‌8.1 Product Marking‌ ‌8.2 Quality Inspection Marking‌ ‌8.3 Packaging‌ ‌Appendix A (Normative) Test for Detection and Alarm Performance‌ ‌A.1 Pyrolysis Materials‌ ‌A.2 Test Equipment‌ ‌A.3 Pyrolysis Test 1 Scope This document defines the terms for pyrolysis - sensing electrical fire monitoring detectors, specifies their classification, requirements, inspection rules, and markings, and describes the corresponding test methods. This document applies to pyrolysis - sensing electrical fire monitoring detectors in electrical fire monitoring systems (hereinafter referred to as "detectors") for the design, manufacture, and inspection of such products. 2 Normative References The contents of the following documents are incorporated into this document by reference. Where a date is specified, only the version corresponding to that date applies to this document. Where no date is specified, the latest version (including all amendments) applies to this document. GB/T 9969 General Rules for Industrial Product Instruction Manuals GB 12978 Inspection Rules for Fire Protection Electronic Products GB 14287 (all parts) Electrical Fire Monitoring Systems GB/T 16838 Environmental Test Methods and Severity Levels for Fire Protection Electronic Products GB/T 17626.2 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 3: Radiated RF Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility — Tests and Measurement Techniques — Surge (Impulse) Immunity Test GB/T 17626.6 Electromagnetic Compatibility — Tests and Measurement Techniques — Conducted RF Immunity Test GB/T 17626.8 Electromagnetic Compatibility — Tests and Measurement Techniques — Power Frequency Magnetic Field Immunity Test GB/T 17626.11 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 11: Immunity Test for Voltage Dips, Short Interruptions, and Voltage Variations for Equipment with Each Phase Input Current ≤ 16 A 3 Terms and Definitions The following terms and definitions apply to this document. ‌3.1‌ Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that monitors changes in pyrolysis particles in the protected area. ‌3.1.1‌ Independent Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that independently detects changes in pyrolysis particles in the protected area and issues audible and visual alarm signals. Note: Abbreviated as "independent detector". ‌3.1.2‌ Non - Independent Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that detects changes in pyrolysis particles in the protected area and transmits relevant information to an electrical fire monitoring device. Note: Abbreviated as "non - independent detector". ‌3.2‌ Combined Multi - Sensing Electrical Fire Monitoring Detector A detector with multiple sensors that can monitor two or more physical quantities (such as residual current, temperature, fault arcs, pyrolysis particles, and insulation performance) in the protected area. ‌3.3‌ Signal Processing Unit A unit that receives measurement data from pyrolysis particle sensors and processes the data. 4 Classification Detectors are classified by their mode of operation as follows: a) Independent; b) Non - independent. 5 Requirements ‌5.1 General Requirements‌ Detectors shall meet the requirements of this chapter and be tested in accordance with Chapter 6 to confirm compliance with these requirements. Combined multi - sensing electrical fire monitoring detectors shall also meet the requirements of the corresponding parts of GB 14287 (all parts). ‌5.2 Appearance‌ The surface of the detector shall show no signs of corrosion, peeling of coatings, or bubbling, and no obvious scratches, cracks, burrs, or other mechanical damage. Tightened parts shall not be loose. ‌5.3 Basic Functions‌ ‌5.3.1‌ Detectors shall indicate their normal operating state, alarm state, and fault state. ‌5.3.2‌ Detectors shall not have the function of disconnecting power distribution circuits. ‌5.3.3‌ The power supply for independent detectors shall use AC 220V/50Hz, and the power input terminal shall have a wiring terminal. ‌5.3.4‌ When the protected area meets the alarm conditions, the detector shall light up the alarm indicator. For non - independent detectors, the alarm indication shall remain until the connected electrical fire monitoring device is reset; for independent detectors, the alarm indication shall remain until manually reset. ‌5.3.5‌ For non - independent detectors with external sensors, when the connection line between the detector and the external sensor is open - circuited or short - circuited, the detector shall transmit a fault signal to the connected electrical fire monitoring device. ‌5.3.6‌ The alarm set value of the detector shall be set on the detector or the connected electrical fire monitoring device, but shall be achieved through dedicated tools, passwords, or other means.
Code of China
Standard
GB 14287.5-2025  Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors (English Version)
Standard No.GB 14287.5-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count13500 words
Price(USD)405.0
Implemented on2026-11-1
Deliveryvia email in 1~5 business day
Detail of GB 14287.5-2025
Standard No.
GB 14287.5-2025
English Name
Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors
Chinese Name
电气火灾监控系统 第5部分:测量热解粒子式电气火灾监控探测器
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
13500 words
Price(USD)
405.0
Keywords
GB 14287.5-2025, GB/T 14287.5-2025, GBT 14287.5-2025, GB14287.5-2025, GB 14287.5, GB14287.5, GB/T14287.5-2025, GB/T 14287.5, GB/T14287.5, GBT14287.5-2025, GBT 14287.5, GBT14287.5
Introduction of GB 14287.5-2025
GB 14287.5-2025 Electrical fire monitoring system—Part 5: Pyrolysis sensing electrical fire monitoring detectors English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 55.200 CCS H 57 National Standard of the People's Republic of China ‌GB 14287.5-2025 Electrical fire monitoring system - Part 5: Pyrolysis sensing electrical fire monitoring detectors 电气火灾监控系统 第5部分:测量热解粒子式电气火灾监控探测器 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Preface‌ ‌Introduction‌ ‌1 Scope‌ ‌2 Normative References‌ ‌3 Terms and Definitions‌ ‌4 Classification‌ ‌5 Requirements‌ ‌5.1 General Requirements‌ ‌5.2 Appearance‌ ‌5.3 Basic Functions‌ ‌5.4 Monitoring and Alarm Functions‌ ‌5.5 Communication Functions‌ ‌5.6 Performance of Major Components‌ ‌5.7 Detection and Alarm Performance‌ ‌6 Test Methods‌ ‌6.1 General Requirements‌ ‌6.2 Basic Function Tests‌ ‌6.3 Monitoring and Alarm Function Tests‌ ‌6.4 Communication Function Tests‌ ‌6.5 Detection and Alarm Performance Tests‌ ‌6.6 Repeatability Tests‌ ‌6.7 Insulation Resistance Tests‌ ‌6.8 Leakage Current Tests‌ ‌6.9 Electrical Strength Tests‌ ‌7 Inspection Rules‌ ‌7.1 Factory Inspection‌ ‌7.2 Type Inspection‌ ‌8 Marking and Packaging‌ ‌8.1 Product Marking‌ ‌8.2 Quality Inspection Marking‌ ‌8.3 Packaging‌ ‌Appendix A (Normative) Test for Detection and Alarm Performance‌ ‌A.1 Pyrolysis Materials‌ ‌A.2 Test Equipment‌ ‌A.3 Pyrolysis Test 1 Scope This document defines the terms for pyrolysis - sensing electrical fire monitoring detectors, specifies their classification, requirements, inspection rules, and markings, and describes the corresponding test methods. This document applies to pyrolysis - sensing electrical fire monitoring detectors in electrical fire monitoring systems (hereinafter referred to as "detectors") for the design, manufacture, and inspection of such products. 2 Normative References The contents of the following documents are incorporated into this document by reference. Where a date is specified, only the version corresponding to that date applies to this document. Where no date is specified, the latest version (including all amendments) applies to this document. GB/T 9969 General Rules for Industrial Product Instruction Manuals GB 12978 Inspection Rules for Fire Protection Electronic Products GB 14287 (all parts) Electrical Fire Monitoring Systems GB/T 16838 Environmental Test Methods and Severity Levels for Fire Protection Electronic Products GB/T 17626.2 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 3: Radiated RF Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility — Tests and Measurement Techniques — Surge (Impulse) Immunity Test GB/T 17626.6 Electromagnetic Compatibility — Tests and Measurement Techniques — Conducted RF Immunity Test GB/T 17626.8 Electromagnetic Compatibility — Tests and Measurement Techniques — Power Frequency Magnetic Field Immunity Test GB/T 17626.11 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 11: Immunity Test for Voltage Dips, Short Interruptions, and Voltage Variations for Equipment with Each Phase Input Current ≤ 16 A 3 Terms and Definitions The following terms and definitions apply to this document. ‌3.1‌ Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that monitors changes in pyrolysis particles in the protected area. ‌3.1.1‌ Independent Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that independently detects changes in pyrolysis particles in the protected area and issues audible and visual alarm signals. Note: Abbreviated as "independent detector". ‌3.1.2‌ Non - Independent Pyrolysis - Sensing Electrical Fire Monitoring Detector A detector that detects changes in pyrolysis particles in the protected area and transmits relevant information to an electrical fire monitoring device. Note: Abbreviated as "non - independent detector". ‌3.2‌ Combined Multi - Sensing Electrical Fire Monitoring Detector A detector with multiple sensors that can monitor two or more physical quantities (such as residual current, temperature, fault arcs, pyrolysis particles, and insulation performance) in the protected area. ‌3.3‌ Signal Processing Unit A unit that receives measurement data from pyrolysis particle sensors and processes the data. 4 Classification Detectors are classified by their mode of operation as follows: a) Independent; b) Non - independent. 5 Requirements ‌5.1 General Requirements‌ Detectors shall meet the requirements of this chapter and be tested in accordance with Chapter 6 to confirm compliance with these requirements. Combined multi - sensing electrical fire monitoring detectors shall also meet the requirements of the corresponding parts of GB 14287 (all parts). ‌5.2 Appearance‌ The surface of the detector shall show no signs of corrosion, peeling of coatings, or bubbling, and no obvious scratches, cracks, burrs, or other mechanical damage. Tightened parts shall not be loose. ‌5.3 Basic Functions‌ ‌5.3.1‌ Detectors shall indicate their normal operating state, alarm state, and fault state. ‌5.3.2‌ Detectors shall not have the function of disconnecting power distribution circuits. ‌5.3.3‌ The power supply for independent detectors shall use AC 220V/50Hz, and the power input terminal shall have a wiring terminal. ‌5.3.4‌ When the protected area meets the alarm conditions, the detector shall light up the alarm indicator. For non - independent detectors, the alarm indication shall remain until the connected electrical fire monitoring device is reset; for independent detectors, the alarm indication shall remain until manually reset. ‌5.3.5‌ For non - independent detectors with external sensors, when the connection line between the detector and the external sensor is open - circuited or short - circuited, the detector shall transmit a fault signal to the connected electrical fire monitoring device. ‌5.3.6‌ The alarm set value of the detector shall be set on the detector or the connected electrical fire monitoring device, but shall be achieved through dedicated tools, passwords, or other means.
Contents of GB 14287.5-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 14287.5-2025, GB/T 14287.5-2025, GBT 14287.5-2025, GB14287.5-2025, GB 14287.5, GB14287.5, GB/T14287.5-2025, GB/T 14287.5, GB/T14287.5, GBT14287.5-2025, GBT 14287.5, GBT14287.5