2025-12-14 10.2.82.121
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 14287.7-2025
GB 14287.7-2025   Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention (English Version)
Standard No.: GB 14287.7-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):405.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1~5 business day

→ → →

,,2026-11-1,9022419B3360AC4E1762263304514
Standard No.: GB 14287.7-2025
English Name: Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention
Chinese Name: 电气火灾监控系统 第7部分:电气防火限流式保护器
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-11-1
Status: to be valid
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 405.0
Delivery: via email in 1~5 business day
GB 14287.7-2025 Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 55.200 CCS H 57 National Standard of the People's Republic of China ‌GB 14287.7-2025 Electrical fire monitoring system - Part 7: Current limiting protector for electric fire prevention 电气火灾监控系统 第7部分:电气防火限流式保护器 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents ‌Foreword‌ ‌Introduction‌ ‌1 Scope‌ ‌2 Normative References‌ ‌3 Terms and Definitions‌ ‌4 Requirements‌ ‌4.1 General Requirements‌ ‌4.2 Packaging and Appearance‌ ‌4.3 Basic Functions‌ ‌4.4 Alarm Performance‌ ‌4.5 Non - Action Performance‌ ‌4.6 Repeatability‌ ‌4.7 Voltage Fluctuation‌ ‌4.8 Climate Environmental Tolerance‌ ‌5 Test Methods‌ ‌5.1 General Requirements‌ ‌5.2 Basic Function Inspection‌ ‌5.3 Alarm Performance Test‌ ‌5.4 Non - Action Performance Test‌ ‌5.5 Repeatability Test‌ ‌5.6 Voltage Fluctuation Test‌ ‌5.7 Low - Temperature (Operation) Test‌ ‌5.8 Constant Humidity and Heat (Operation) Test‌ ‌5.9 Impact (Operation) Test‌ ‌5.10 Collision (Operation) Test‌ ‌6 Inspection Rules‌ ‌6.1 Factory Inspection‌ ‌6.2 Type Inspection‌ ‌7 Marking‌ ‌7.1 Product Marking‌ ‌7.2 Quality Inspection Marking‌ ‌Appendix A (Normative) Combustion Performance of Enclosure 1 Scope This document defines the terms for current - limiting protectors for electric fire prevention, specifies the requirements, inspection rules, and markings, and describes the corresponding test methods. This document applies to current - limiting protectors for electric fire prevention in electrical fire monitoring systems (hereinafter referred to as "protectors") for the design, manufacture, and inspection of such products. 2 Normative References The contents of the following documents are incorporated into this document by reference. Where a date is specified, only the version corresponding to that date applies to this document. Where no date is specified, the latest version (including all amendments) applies to this document. GB/T 9969 General Rules for Industrial Product Instruction Manuals GB 12978 Inspection Rules for Fire Protection Electronic Products GB/T 16838 Environmental Test Methods and Severity Levels for Fire Protection Electronic Products GB/T 17626.2 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 3: Radiated RF Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility — Tests and Measurement Techniques — Surge (Impulse) Immunity Test GB/T 17626.6 Electromagnetic Compatibility — Tests and Measurement Techniques — Conducted RF Immunity Test 3 Terms and Definitions The following terms and definitions apply to this document. ‌3.1‌ Current - Limiting Protector for Electric Fire Prevention A protective device that limits current in the protected circuit when a short circuit or overload occurs. ‌3.2‌ Rated Current The maximum current value that the protector can continuously pass through safely under normal operating conditions. ‌3.3‌ Short - Circuit Protection Current The minimum current that triggers the protector's short - circuit protection. ‌3.4‌ Overload Protection Current The minimum current that triggers the protector's overload protection. ‌3.5‌ Short - Circuit Protection Time The time from when a short circuit occurs in the protected circuit to when the protector completes current limiting protection. ‌3.6‌ Current - Limiting Time The time from when the protector starts current limiting to when it completes current limiting protection. ‌3.7‌ Overload Protection Time The time from when the current value of the protected circuit reaches the overload protection current setting value to when current limiting protection is completed. 4 Requirements ‌4.1 General Requirements‌ Protectors shall meet the requirements of this chapter and be tested in accordance with Chapter 5 to confirm compliance with these requirements. ‌4.2 Packaging and Appearance‌ ‌4.2.1‌ Protectors shall have complete packaging at the time of factory release. The protector surface shall have product markings, and the packaging shall include quality inspection pass markings and instruction manuals. ‌4.2.2‌ The surface of the protector shall show no signs of corrosion, peeling of coatings, or bubbling, and no obvious scratches, cracks, burrs, or other mechanical damage. Tightened parts shall not be loose. ‌4.3 Basic Functions‌ ‌4.3.1‌ Indicator Lights Protectors shall have independent indicator lights for their working status, separately indicating normal monitoring status and alarm status. The normal monitoring status indicator shall be green, and the alarm status indicator shall be red. The indicator lights shall have Chinese functional annotations. In the 3 m range directly in front of the indicator lights and in an environment with illuminance not exceeding 500 lx, the indicator lights shall be clearly visible. Note: The normal monitoring status refers to the state where the protector is powered on and working normally, has not triggered current limiting protection, and has not issued an alarm signal. ‌4.3.2‌ Audible Devices In alarm conditions, the sound pressure level (A - weighted) of the protector's audible device in the 1 m range directly in front of it shall be greater than 70 dB and less than 115 dB. ‌4.3.3‌ Protective Alarm Function Producers shall specify the rated current, short - circuit protection current, and overload protection current of the protector. When the protected circuit experiences an overload or short circuit, the protector shall trigger current limiting protection, issue audible and visual alarm signals within 3 seconds, and maintain the alarm until the protector is reset. ‌4.3.4‌ Reset Function Protectors shall have a reset button, which shall have measures to prevent accidental operation. After the overload or short circuit of the protected circuit is eliminated, the protector shall be able to return to the normal monitoring status by operating the reset button. ‌4.3.5‌ Self - Inspection Function Protectors shall be able to manually check their audible devices and all indicator lights on the panel. During self - inspection, the protector shall not trigger current limiting protection. ‌4.3.6‌ Communication Function Protectors shall have at least one communication interface. Protectors shall be able to transmit their working status to the connected display device through the communication interface. ‌4.3.7‌ Factory Settings
Code of China
Standard
GB 14287.7-2025  Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention (English Version)
Standard No.GB 14287.7-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count13500 words
Price(USD)405.0
Implemented on2026-11-1
Deliveryvia email in 1~5 business day
Detail of GB 14287.7-2025
Standard No.
GB 14287.7-2025
English Name
Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention
Chinese Name
电气火灾监控系统 第7部分:电气防火限流式保护器
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
13500 words
Price(USD)
405.0
Keywords
GB 14287.7-2025, GB/T 14287.7-2025, GBT 14287.7-2025, GB14287.7-2025, GB 14287.7, GB14287.7, GB/T14287.7-2025, GB/T 14287.7, GB/T14287.7, GBT14287.7-2025, GBT 14287.7, GBT14287.7
Introduction of GB 14287.7-2025
GB 14287.7-2025 Electrical fire monitoring system—Part 7: Current limiting protector for electric fire prevention English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 55.200 CCS H 57 National Standard of the People's Republic of China ‌GB 14287.7-2025 Electrical fire monitoring system - Part 7: Current limiting protector for electric fire prevention 电气火灾监控系统 第7部分:电气防火限流式保护器 Issue date: 2025-10-31 Implementation date: 2026-11-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents ‌Foreword‌ ‌Introduction‌ ‌1 Scope‌ ‌2 Normative References‌ ‌3 Terms and Definitions‌ ‌4 Requirements‌ ‌4.1 General Requirements‌ ‌4.2 Packaging and Appearance‌ ‌4.3 Basic Functions‌ ‌4.4 Alarm Performance‌ ‌4.5 Non - Action Performance‌ ‌4.6 Repeatability‌ ‌4.7 Voltage Fluctuation‌ ‌4.8 Climate Environmental Tolerance‌ ‌5 Test Methods‌ ‌5.1 General Requirements‌ ‌5.2 Basic Function Inspection‌ ‌5.3 Alarm Performance Test‌ ‌5.4 Non - Action Performance Test‌ ‌5.5 Repeatability Test‌ ‌5.6 Voltage Fluctuation Test‌ ‌5.7 Low - Temperature (Operation) Test‌ ‌5.8 Constant Humidity and Heat (Operation) Test‌ ‌5.9 Impact (Operation) Test‌ ‌5.10 Collision (Operation) Test‌ ‌6 Inspection Rules‌ ‌6.1 Factory Inspection‌ ‌6.2 Type Inspection‌ ‌7 Marking‌ ‌7.1 Product Marking‌ ‌7.2 Quality Inspection Marking‌ ‌Appendix A (Normative) Combustion Performance of Enclosure 1 Scope This document defines the terms for current - limiting protectors for electric fire prevention, specifies the requirements, inspection rules, and markings, and describes the corresponding test methods. This document applies to current - limiting protectors for electric fire prevention in electrical fire monitoring systems (hereinafter referred to as "protectors") for the design, manufacture, and inspection of such products. 2 Normative References The contents of the following documents are incorporated into this document by reference. Where a date is specified, only the version corresponding to that date applies to this document. Where no date is specified, the latest version (including all amendments) applies to this document. GB/T 9969 General Rules for Industrial Product Instruction Manuals GB 12978 Inspection Rules for Fire Protection Electronic Products GB/T 16838 Environmental Test Methods and Severity Levels for Fire Protection Electronic Products GB/T 17626.2 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility — Tests and Measurement Techniques — Part 3: Radiated RF Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility — Tests and Measurement Techniques — Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility — Tests and Measurement Techniques — Surge (Impulse) Immunity Test GB/T 17626.6 Electromagnetic Compatibility — Tests and Measurement Techniques — Conducted RF Immunity Test 3 Terms and Definitions The following terms and definitions apply to this document. ‌3.1‌ Current - Limiting Protector for Electric Fire Prevention A protective device that limits current in the protected circuit when a short circuit or overload occurs. ‌3.2‌ Rated Current The maximum current value that the protector can continuously pass through safely under normal operating conditions. ‌3.3‌ Short - Circuit Protection Current The minimum current that triggers the protector's short - circuit protection. ‌3.4‌ Overload Protection Current The minimum current that triggers the protector's overload protection. ‌3.5‌ Short - Circuit Protection Time The time from when a short circuit occurs in the protected circuit to when the protector completes current limiting protection. ‌3.6‌ Current - Limiting Time The time from when the protector starts current limiting to when it completes current limiting protection. ‌3.7‌ Overload Protection Time The time from when the current value of the protected circuit reaches the overload protection current setting value to when current limiting protection is completed. 4 Requirements ‌4.1 General Requirements‌ Protectors shall meet the requirements of this chapter and be tested in accordance with Chapter 5 to confirm compliance with these requirements. ‌4.2 Packaging and Appearance‌ ‌4.2.1‌ Protectors shall have complete packaging at the time of factory release. The protector surface shall have product markings, and the packaging shall include quality inspection pass markings and instruction manuals. ‌4.2.2‌ The surface of the protector shall show no signs of corrosion, peeling of coatings, or bubbling, and no obvious scratches, cracks, burrs, or other mechanical damage. Tightened parts shall not be loose. ‌4.3 Basic Functions‌ ‌4.3.1‌ Indicator Lights Protectors shall have independent indicator lights for their working status, separately indicating normal monitoring status and alarm status. The normal monitoring status indicator shall be green, and the alarm status indicator shall be red. The indicator lights shall have Chinese functional annotations. In the 3 m range directly in front of the indicator lights and in an environment with illuminance not exceeding 500 lx, the indicator lights shall be clearly visible. Note: The normal monitoring status refers to the state where the protector is powered on and working normally, has not triggered current limiting protection, and has not issued an alarm signal. ‌4.3.2‌ Audible Devices In alarm conditions, the sound pressure level (A - weighted) of the protector's audible device in the 1 m range directly in front of it shall be greater than 70 dB and less than 115 dB. ‌4.3.3‌ Protective Alarm Function Producers shall specify the rated current, short - circuit protection current, and overload protection current of the protector. When the protected circuit experiences an overload or short circuit, the protector shall trigger current limiting protection, issue audible and visual alarm signals within 3 seconds, and maintain the alarm until the protector is reset. ‌4.3.4‌ Reset Function Protectors shall have a reset button, which shall have measures to prevent accidental operation. After the overload or short circuit of the protected circuit is eliminated, the protector shall be able to return to the normal monitoring status by operating the reset button. ‌4.3.5‌ Self - Inspection Function Protectors shall be able to manually check their audible devices and all indicator lights on the panel. During self - inspection, the protector shall not trigger current limiting protection. ‌4.3.6‌ Communication Function Protectors shall have at least one communication interface. Protectors shall be able to transmit their working status to the connected display device through the communication interface. ‌4.3.7‌ Factory Settings
Contents of GB 14287.7-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 14287.7-2025, GB/T 14287.7-2025, GBT 14287.7-2025, GB14287.7-2025, GB 14287.7, GB14287.7, GB/T14287.7-2025, GB/T 14287.7, GB/T14287.7, GBT14287.7-2025, GBT 14287.7, GBT14287.7