GB 14443-2025   Safety technical requirements for paint oven (English Version)
Standard No.: GB 14443-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):255.0 remind me the price change

Email:

Implemented on:2026-8-1 Delivery: via email in 1~3 business day

→ → →

,,2026-8-1,D066A86CCB7AF71C1762263304698
Standard No.: GB 14443-2025
English Name: Safety technical requirements for paint oven
Chinese Name: 涂层烘干室安全技术要求
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-8-1
Status: to be valid
Superseding:GB 14443-2007 Safety code for painting — Safety rules for paint drying oven
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 255.0
Delivery: via email in 1~3 business day
This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.100 CCS C 68 National Standard of the People’s Republic of China GB 14443-2025 Replaces GB 14444-2007 Safety technical requirements for paint oven 涂层烘干室安全技术要求 Issue date: 2025-10-31 Implementation date: 2026-08-01 Issued by the State Administration for Market Regulation of the People's Republic of China the Standardization Administration of the People's Republic of China Safety technical requirements for paint oven 1 Scope This document specifies the safety technical requirements for the structure, electrical equipment, heating systems, ventilation systems, control facilities, pressure relief facilities, operation, and maintenance of paint drying ovens, and describes the verification methods. This document applies to drying ovens used for coatings derived from combustible and flammable liquid paints and powder coatings. 2 Normative References The contents of the following documents constitute essential provisions of this document through normative reference in the text. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 2894 Safety colours and safety signs GB/T 3836.1 Explosive atmospheres - Part 1: Equipment - General requirements GB/T 3836.15 Explosive atmospheres - Part 15: Design, selection and erection of electrical installations GB 4053 (all parts) Safety requirements for fixed steel ladders and platforms GB/T 4272 General principles for thermal insulation technology of equipment and pipelines GB/T 4942 Classification of degrees of protection provided by enclosures for rotating electrical machines (IP Code) GB 5959.13 Safety in electroheating installations - Part 13: Particular requirements for electroheating installations with an atmosphere containing flammable material GB 6514 Safety code for painting - Safety of painting process and its ventilation GB/T 8175 Guide for thermal insulation design of equipment and pipelines GB/T 14441 Terminology of safety for painting GB 15930 Fire dampers for building ventilation and smoke control systems GB 16297 Integrated emission standard of air pollutants GB/T 19839 General technical conditions for industrial oil and gas burners GB 20101 Safety technical requirements for purification euipment of organic waste gas from painting GB 50058 Code for design of electrical installations in explosive atmospheres GB/T 50087 Code for design of noise control of industrial enterprises GB 50140 Code for design of fire extinguisher distribution in buildings 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 14441 and the following apply. 3.1 paint drying oven An enclosure where coatings are dried or cured by heating. Note: Classified by heating method into radiation drying ovens and convection drying ovens; by operation mode into batch process ovens and continuous process ovens; by coating composition into solvent-based coating drying ovens, water-based coating drying ovens, and powder coating drying ovens, etc. 3.2 ignition temperature The minimum temperature required, under specified test conditions, to ignite an explosive mixture. 3.3 safety ventilation of oven Ventilation within the drying oven to control the concentration of combustible gases (or powders), ensuring that the concentration of combustible gases (or powders) in any part of the oven remains below the maximum allowable percentage under any operating condition. Note: Safety ventilation methods mainly include: supplying an adequate amount of fresh air; organizing reasonable air circulation flow to purify or discharge high-concentration exhaust gases to appropriate areas. 3.4 direct-fired heating system A heating system for drying ovens where the combustion products enter the oven's workspace and directly contact and heat the workpieces. [Source: GB/T 14441-2024, 7.1.5] 3.5 indirect-fired heating system A heating system for drying ovens where the combustion products are hermetically separated from the oven's workspace and indirectly heat the workpieces. [Source: GB/T 14441-2024, 7.1.6] 3.6 air re-circulation system A complete set of devices that systematically extract air from the workspace of the drying oven and return it. Note: Used to meet the requirements of convective hot air heating and to organize safety ventilation, preventing the accumulation of combustibles in the indoor air. 3.7 batch process oven A drying oven where workpieces are loaded intermittently and the drying/curing operation is performed cyclically. 3.8 continuous process oven A drying oven where workpieces are loaded continuously and the drying/curing operation is performed continuously. 3.9 ultra-violet oven A drying oven that uses ultraviolet light to dry or cure wet coatings. 4 General Requirements 4.1 When drying workpieces made of flammable materials (paper, cloth, plastic, etc.), the paint drying oven (hereinafter referred to as "the oven") shall have measures in place to prevent ignition of the workpieces. 4.2 Fire dampers or electric air dampers, or other devices capable of closing the exhaust, shall be installed on the exhaust ducts of the oven. Fire dampers shall comply with GB 15930. In the event of a fire inside the oven, the device shall automatically close the damper, simultaneously stop the circulation fan and exhaust fan automatically, and activate audible and visual alarms. 4.3 Flammable or explosive materials shall not be stored around the oven. 4.4 Fire-fighting equipment shall be provided near the oven according to the relevant provisions of GB 50140. 4.5 When flammable or combustible vapors are released, or combustible gases are present, during the drying or curing of coatings on workpieces inside the oven, the interior of the oven shall be classified as a Zone 1 hazardous area. The area within 3 meters horizontally and vertically from the loading door shall be classified as a Zone 2 hazardous area. If pits associated with the oven connect to the hazardous area, the classification of the hazardous areas shall comply with GB 50058.
Contents Foreword III 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 5 Equipment and Facilities 6 Operation and Maintenance 7 Verification Methods Appendix A (Normative) Calculation of Fresh Air Volume for Solvent-Based Coating Drying Ovens
Code of China
Standard
GB 14443-2025  Safety technical requirements for paint oven (English Version)
Standard No.GB 14443-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)255.0
Implemented on2026-8-1
Deliveryvia email in 1~3 business day
Detail of GB 14443-2025
Standard No.
GB 14443-2025
English Name
Safety technical requirements for paint oven
Chinese Name
涂层烘干室安全技术要求
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-8-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 14443-2007 Safety code for painting — Safety rules for paint drying oven
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
255.0
Keywords
GB 14443-2025, GB/T 14443-2025, GBT 14443-2025, GB14443-2025, GB 14443, GB14443, GB/T14443-2025, GB/T 14443, GB/T14443, GBT14443-2025, GBT 14443, GBT14443
Introduction of GB 14443-2025
This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.100 CCS C 68 National Standard of the People’s Republic of China GB 14443-2025 Replaces GB 14444-2007 Safety technical requirements for paint oven 涂层烘干室安全技术要求 Issue date: 2025-10-31 Implementation date: 2026-08-01 Issued by the State Administration for Market Regulation of the People's Republic of China the Standardization Administration of the People's Republic of China Safety technical requirements for paint oven 1 Scope This document specifies the safety technical requirements for the structure, electrical equipment, heating systems, ventilation systems, control facilities, pressure relief facilities, operation, and maintenance of paint drying ovens, and describes the verification methods. This document applies to drying ovens used for coatings derived from combustible and flammable liquid paints and powder coatings. 2 Normative References The contents of the following documents constitute essential provisions of this document through normative reference in the text. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 2894 Safety colours and safety signs GB/T 3836.1 Explosive atmospheres - Part 1: Equipment - General requirements GB/T 3836.15 Explosive atmospheres - Part 15: Design, selection and erection of electrical installations GB 4053 (all parts) Safety requirements for fixed steel ladders and platforms GB/T 4272 General principles for thermal insulation technology of equipment and pipelines GB/T 4942 Classification of degrees of protection provided by enclosures for rotating electrical machines (IP Code) GB 5959.13 Safety in electroheating installations - Part 13: Particular requirements for electroheating installations with an atmosphere containing flammable material GB 6514 Safety code for painting - Safety of painting process and its ventilation GB/T 8175 Guide for thermal insulation design of equipment and pipelines GB/T 14441 Terminology of safety for painting GB 15930 Fire dampers for building ventilation and smoke control systems GB 16297 Integrated emission standard of air pollutants GB/T 19839 General technical conditions for industrial oil and gas burners GB 20101 Safety technical requirements for purification euipment of organic waste gas from painting GB 50058 Code for design of electrical installations in explosive atmospheres GB/T 50087 Code for design of noise control of industrial enterprises GB 50140 Code for design of fire extinguisher distribution in buildings 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 14441 and the following apply. 3.1 paint drying oven An enclosure where coatings are dried or cured by heating. Note: Classified by heating method into radiation drying ovens and convection drying ovens; by operation mode into batch process ovens and continuous process ovens; by coating composition into solvent-based coating drying ovens, water-based coating drying ovens, and powder coating drying ovens, etc. 3.2 ignition temperature The minimum temperature required, under specified test conditions, to ignite an explosive mixture. 3.3 safety ventilation of oven Ventilation within the drying oven to control the concentration of combustible gases (or powders), ensuring that the concentration of combustible gases (or powders) in any part of the oven remains below the maximum allowable percentage under any operating condition. Note: Safety ventilation methods mainly include: supplying an adequate amount of fresh air; organizing reasonable air circulation flow to purify or discharge high-concentration exhaust gases to appropriate areas. 3.4 direct-fired heating system A heating system for drying ovens where the combustion products enter the oven's workspace and directly contact and heat the workpieces. [Source: GB/T 14441-2024, 7.1.5] 3.5 indirect-fired heating system A heating system for drying ovens where the combustion products are hermetically separated from the oven's workspace and indirectly heat the workpieces. [Source: GB/T 14441-2024, 7.1.6] 3.6 air re-circulation system A complete set of devices that systematically extract air from the workspace of the drying oven and return it. Note: Used to meet the requirements of convective hot air heating and to organize safety ventilation, preventing the accumulation of combustibles in the indoor air. 3.7 batch process oven A drying oven where workpieces are loaded intermittently and the drying/curing operation is performed cyclically. 3.8 continuous process oven A drying oven where workpieces are loaded continuously and the drying/curing operation is performed continuously. 3.9 ultra-violet oven A drying oven that uses ultraviolet light to dry or cure wet coatings. 4 General Requirements 4.1 When drying workpieces made of flammable materials (paper, cloth, plastic, etc.), the paint drying oven (hereinafter referred to as "the oven") shall have measures in place to prevent ignition of the workpieces. 4.2 Fire dampers or electric air dampers, or other devices capable of closing the exhaust, shall be installed on the exhaust ducts of the oven. Fire dampers shall comply with GB 15930. In the event of a fire inside the oven, the device shall automatically close the damper, simultaneously stop the circulation fan and exhaust fan automatically, and activate audible and visual alarms. 4.3 Flammable or explosive materials shall not be stored around the oven. 4.4 Fire-fighting equipment shall be provided near the oven according to the relevant provisions of GB 50140. 4.5 When flammable or combustible vapors are released, or combustible gases are present, during the drying or curing of coatings on workpieces inside the oven, the interior of the oven shall be classified as a Zone 1 hazardous area. The area within 3 meters horizontally and vertically from the loading door shall be classified as a Zone 2 hazardous area. If pits associated with the oven connect to the hazardous area, the classification of the hazardous areas shall comply with GB 50058.
Contents of GB 14443-2025
Contents Foreword III 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 5 Equipment and Facilities 6 Operation and Maintenance 7 Verification Methods Appendix A (Normative) Calculation of Fresh Air Volume for Solvent-Based Coating Drying Ovens
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 14443-2025, GB/T 14443-2025, GBT 14443-2025, GB14443-2025, GB 14443, GB14443, GB/T14443-2025, GB/T 14443, GB/T14443, GBT14443-2025, GBT 14443, GBT14443