GB 16280-2014   Line Type Heat Fire Detectors (English Version)
Standard No.: GB 16280-2014 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 14000 words Translation Price(USD):350.0 remind me the price change

Email:

Implemented on:2015-6-1 Delivery: via email in 1 business day

→ → →

,,2015-6-1,8D9F0AC18A90D29E1422610758249
Standard No.: GB 16280-2014
English Name: Line Type Heat Fire Detectors
Chinese Name: 线型感温火灾探测器
Chinese Classification: C81    Fire monitoring, alarming and fire-fighting dispatching system
Professional Classification: GB    National Standard
ICS Classification: 13.220.20 13.220.20    Fire protection 13.220.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2014-06-24
Implemented on: 2015-6-1
Status: valid
Superseding:GB 16280-2005 Line type heat fire detectors
GB/T 21197-2007 Line type heat detectors using optical fibre
Target Language: English
File Format: PDF
Word Count: 14000 words
Translation Price(USD): 350.0
Delivery: via email in 1 business day
1 Scope This standard specifies product classification, technical requirements, test methods, inspection rules and mark of line type heat fire detector. This standard is applicable to cable line type heat fire detector, air tube line type heat fire detector, distributed optical fiber line type heat fire detector, optical fiber grating line type heat fire detector and line type multi-point heat fire detector installed and used in industrial and civil buildings. 2 Normative References The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest edition (including all the amendments) applies. GB/T 2423.4 Environmental Testing for Electric and Electronic Products - Part 2: Test Method - Test Db: Damp Heat, Cyclic (12h+12h cycle) GB/T 2423.18 Environmental Testing - Part 2: Test Methods - Test Kb: Salt Mist, Cyclic (Sodium Chloride Solution) GB 4716 Point Type Heat Fire Detectors GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB 12978 Rules for Test of Fire Electronic Products GB 16838 Environmental Test Methods and Severities for Fire Electronic Products GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement Techniques - Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility-Testing and Measurement Techniques - Radiated Radio-frequency Electromagnetic Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility-Testing and Measurement Techniques-Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility - Testing and Measurement Techniques - Surge Immunity Test GB/T 17626.6 Electromagnetic Compatibility - Testing and Measurement Techniques-Immunity to Conducted Disturbances, Induced by Radio-frequency Fields GB/T 17626.8 Electromagnetic Compatibility - Testing and Measurement Techniques - Power Frequency Magnetic Field Immunity Test GB 23757-2009 Protection Requirements for Fire Electronic Products 3 Product Classification 3.1 Classification according to sensing unit form: a) Cable; b) Air tube; c) Distributed optical fiber; d) Optical fiber grating; e) Lined multi-point type. 3.2 Classification according to operation performance: a) Fixed temperature; b) Rate-of-rise temperature; c) Rate-of-rise and fixed temperature. 3.3 Classification according to recoverable performance: a) Recoverable; b) Irrecoverable. 3.4 Classification according to locating mode: a) Distribution; b) Zoning. 3.5 Classification according to detection alarm function: a) Detection; b) Detection alarm. 4 Technical Requirements
Foreword I 1 Scope 2 Normative References 3 Product Classification 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking
Referred in GB 16280-2014:
*GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat,cyclic ( 12h+12h cycle)
*GB/T 2423.18-2012 Environmental testing - Part 2: Test methods - Test Kb: Salt mist, cyclic (sodium chloride solution)
*GB 4716-2005 Point type heat fire detectors
*GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
*GB 12978-2003 Rules for test of fire electronic products
*GB 16838-2005 Environmental Test Methods and Severities for Fire Electronic Products
*GB/T 17626.2-l998
*GB/T 17626.3-2016
*GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
*GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
*GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques - Immunity to conducted disturbances induced by radio-frequency fields
*GB/T 17626.8-2006 Electromagnetic compatibility (EMC) - Part 8: Testing and measurement techniques - Power frequency magnetic field immunity test
*GB 23757-2009 Protection requirements for fire electronic products
GB 16280-2014 is referred in:
* CJ/T 416-2012 Fire Protection Requirements for Urban Rail Transit Vehicles
Code of China
Standard
GB 16280-2014  Line Type Heat Fire Detectors (English Version)
Standard No.GB 16280-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count14000 words
Price(USD)350.0
Implemented on2015-6-1
Deliveryvia email in 1 business day
Detail of GB 16280-2014
Standard No.
GB 16280-2014
English Name
Line Type Heat Fire Detectors
Chinese Name
线型感温火灾探测器
Chinese Classification
C81
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2014-06-24
Implemented on
2015-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 16280-2005 Line type heat fire detectors
GB/T 21197-2007 Line type heat detectors using optical fibre
Language
English
File Format
PDF
Word Count
14000 words
Price(USD)
350.0
Keywords
GB 16280-2014, GB/T 16280-2014, GBT 16280-2014, GB16280-2014, GB 16280, GB16280, GB/T16280-2014, GB/T 16280, GB/T16280, GBT16280-2014, GBT 16280, GBT16280
Introduction of GB 16280-2014
1 Scope This standard specifies product classification, technical requirements, test methods, inspection rules and mark of line type heat fire detector. This standard is applicable to cable line type heat fire detector, air tube line type heat fire detector, distributed optical fiber line type heat fire detector, optical fiber grating line type heat fire detector and line type multi-point heat fire detector installed and used in industrial and civil buildings. 2 Normative References The following documents are indispensable for the application of this document. For dated references, only the dated editions apply. For undated references, the latest edition (including all the amendments) applies. GB/T 2423.4 Environmental Testing for Electric and Electronic Products - Part 2: Test Method - Test Db: Damp Heat, Cyclic (12h+12h cycle) GB/T 2423.18 Environmental Testing - Part 2: Test Methods - Test Kb: Salt Mist, Cyclic (Sodium Chloride Solution) GB 4716 Point Type Heat Fire Detectors GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB 12978 Rules for Test of Fire Electronic Products GB 16838 Environmental Test Methods and Severities for Fire Electronic Products GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement Techniques - Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility-Testing and Measurement Techniques - Radiated Radio-frequency Electromagnetic Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility-Testing and Measurement Techniques-Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility - Testing and Measurement Techniques - Surge Immunity Test GB/T 17626.6 Electromagnetic Compatibility - Testing and Measurement Techniques-Immunity to Conducted Disturbances, Induced by Radio-frequency Fields GB/T 17626.8 Electromagnetic Compatibility - Testing and Measurement Techniques - Power Frequency Magnetic Field Immunity Test GB 23757-2009 Protection Requirements for Fire Electronic Products 3 Product Classification 3.1 Classification according to sensing unit form: a) Cable; b) Air tube; c) Distributed optical fiber; d) Optical fiber grating; e) Lined multi-point type. 3.2 Classification according to operation performance: a) Fixed temperature; b) Rate-of-rise temperature; c) Rate-of-rise and fixed temperature. 3.3 Classification according to recoverable performance: a) Recoverable; b) Irrecoverable. 3.4 Classification according to locating mode: a) Distribution; b) Zoning. 3.5 Classification according to detection alarm function: a) Detection; b) Detection alarm. 4 Technical Requirements
Contents of GB 16280-2014
Foreword I 1 Scope 2 Normative References 3 Product Classification 4 Technical Requirements 5 Test Methods 6 Inspection Rules 7 Marking