2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 16556-2025
GB 16556-2025   Respiratory protection—Self-contained open-circuit compressed air breathing apparatus (English Version)
Standard No.: GB 16556-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 19500 words Translation Price(USD):585.0 remind me the price change

Email:

Implemented on:2026-9-1 Delivery: via email in 1~5 business day

→ → →

,,2026-9-1,5965584639955C6C1756952095092
Standard No.: GB 16556-2025
English Name: Respiratory protection—Self-contained open-circuit compressed air breathing apparatus
Chinese Name: 呼吸防护 自给开路式压缩空气呼吸器
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-08-29
Implemented on: 2026-9-1
Status: to be valid
Superseding:GB/T 16556-2007 Self-contained open-circuit compressed air breathing apparatus
Target Language: English
File Format: PDF
Word Count: 19500 words
Translation Price(USD): 585.0
Delivery: via email in 1~5 business day
GB 16556-2025 Respiratory protection—Self-contained open-circuit compressed air breathing apparatus ICS13.340.30 CCSC73 National Standard of the People's Republic of China GB16556-2025 Replaces GB/T16556-2007 Respiratory protection—Self-contained open-circuit compressed air breathing apparatus Released on August 29, 2025 Implementation on September 1, 2026 State Administration for Market Regulation, National Standardization Administration Contents Preface 1 Scope 2 Normative references 3 Terms and Definitions 4 Classification and Labeling 5 Technical Requirements 6 Test methods 7 Labelling, packaging and information provided by the manufacturer Appendix A (Normative) Flame Engulfment Test Method References Respiratory protection—Self-contained open-circuit compressed air breathing apparatus 1 Scope This document specifies the technical requirements, labeling, packaging and manufacturer information for self-contained open-circuit compressed air breathing apparatus, and gives the classification and markings, describing the corresponding test methods. This document applies to self-contained open-circuit compressed air breathing apparatus for industrial and emergency use (hereinafter referred to as air breathing apparatus). This document does not apply to closed-circuit breathing apparatus, diving breathing apparatus, escape air breathing apparatus and negative pressure air breathing apparatus. 2 Normative references The contents of the following documents constitute essential provisions of this document through normative references. For dated references, only the version corresponding to that date applies to this document. For undated references, the latest version (including all amendments) applies to this document. GB/T1226 General pressure gauge GB2626-2019 Respiratory protection self-priming filter type anti-particulate respirator GB2890-2022 Respiratory protection self-priming filter type gas mask GB/T3836.1 Explosive atmospheres Part 1: General requirements for equipment GB/T3836.4 Explosive atmospheres Part 4: Equipment protected by intrinsic safety type "i" GB/T4208—2017 Degrees of protection provided by enclosures (IP code) GB/T5099.1 Seamless Steel Gas Cylinders Part 1: Steel Cylinders with a Tensile Strength of Less than 1100 MPa After Quenching and Tempering GB/T5099.3 Seamless Steel Gas Cylinders Part 3: Normalized Steel Cylinders GB/T5099.4 Seamless Steel Gas Cylinders Part 4: Stainless Steel Seamless Gas Cylinders GB/T7307—2001 55° Non-Sealing Pipe Thread GB/T12903 Terminology of Personal Protective Equipment GB14866—2023 General Technical Specification for Eye and Face Protective Equipment GB/T23465—2009 Practical Performance Evaluation of Respiratory Protective Equipment GB/T28053 Aluminum Alloy Liner Carbon Fiber Fully Wrapped Gas Cylinders GB31975 Technical Requirements for Respiratory Protection of Compressed Air GB/T32166.2—2015 Personal protective equipment Eye and face protection Occupational eye and face protection Part 2: Measurement methods GB/T34527 Technical requirements for cylinder valves for air breathing apparatus 3 Terms and Definitions The terms and definitions defined in GB/T 12903 and the following apply to this document. 3.1 Self-contained open-circuit compressed air breathing apparatus uses the mask to fit closely around the wearer's face, isolating the wearer's respiratory organs, eyes and face from the outside toxic and harmful air or oxygen-deficient environment. A type of respirator that is completely isolated and requires the personnel to carry their own clean compressed air as the breathing air source, and the exhaled gas is directly discharged into the ambient air. 3.2 Emergency air breathing apparatus self-contained open-circuit compressed air breathing apparatus for fire-fighting andemergencyservices A self-contained open-circuit compressed air breathing apparatus used by workers undertaking emergency tasks such as firefighting, hazardous chemicals disposal, and rescue. 3.3 Industrial air respirator self-contained open-circuit compressed air breathing apparatus for industrial services In addition to the emergency air respirator applicable areas, mining, petrochemical, industry and trade, smelting, transportation, municipal construction, public utilities and other A self-contained open-circuit compressed air respirator used by workers in various industries. 3.4 Static pressure is the pressure inside the mask cavity when the air circuit of the air respirator is balanced after the positive pressure device of the air supply valve is opened. 4 Classification and labeling 4.1 Classification 4.1.1 Classification by applicable occasions According to their applicable occasions, air respirators are divided into: a) industrial air respirators, marking code: GY; b) emergency air respirators, marking code: YJ. 4.1.2 Classification by gas cylinder material According to the type of gas cylinder material, air breathing apparatus are divided into: a) seamless steel gas cylinders, marked with code: G; b) aluminum alloy liner carbon fiber fully wrapped gas cylinders (referred to as "composite gas cylinders"), marked with code: F. 4.1.3 Classification by nominal volume of gas cylinders The nominal volume of the gas cylinder of an air breathing apparatus should be no less than 3 L and no more than 12 L. Gas cylinders may be marked as 3, 4.7, 6.8, 8, 9, 12, etc. according to their actual nominal volume. 4.2 Marking
Code of China
Standard
GB 16556-2025  Respiratory protection—Self-contained open-circuit compressed air breathing apparatus (English Version)
Standard No.GB 16556-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count19500 words
Price(USD)585.0
Implemented on2026-9-1
Deliveryvia email in 1~5 business day
Detail of GB 16556-2025
Standard No.
GB 16556-2025
English Name
Respiratory protection—Self-contained open-circuit compressed air breathing apparatus
Chinese Name
呼吸防护 自给开路式压缩空气呼吸器
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-08-29
Implemented on
2026-9-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 16556-2007 Self-contained open-circuit compressed air breathing apparatus
Language
English
File Format
PDF
Word Count
19500 words
Price(USD)
585.0
Keywords
GB 16556-2025, GB/T 16556-2025, GBT 16556-2025, GB16556-2025, GB 16556, GB16556, GB/T16556-2025, GB/T 16556, GB/T16556, GBT16556-2025, GBT 16556, GBT16556
Introduction of GB 16556-2025
GB 16556-2025 Respiratory protection—Self-contained open-circuit compressed air breathing apparatus ICS13.340.30 CCSC73 National Standard of the People's Republic of China GB16556-2025 Replaces GB/T16556-2007 Respiratory protection—Self-contained open-circuit compressed air breathing apparatus Released on August 29, 2025 Implementation on September 1, 2026 State Administration for Market Regulation, National Standardization Administration Contents Preface 1 Scope 2 Normative references 3 Terms and Definitions 4 Classification and Labeling 5 Technical Requirements 6 Test methods 7 Labelling, packaging and information provided by the manufacturer Appendix A (Normative) Flame Engulfment Test Method References Respiratory protection—Self-contained open-circuit compressed air breathing apparatus 1 Scope This document specifies the technical requirements, labeling, packaging and manufacturer information for self-contained open-circuit compressed air breathing apparatus, and gives the classification and markings, describing the corresponding test methods. This document applies to self-contained open-circuit compressed air breathing apparatus for industrial and emergency use (hereinafter referred to as air breathing apparatus). This document does not apply to closed-circuit breathing apparatus, diving breathing apparatus, escape air breathing apparatus and negative pressure air breathing apparatus. 2 Normative references The contents of the following documents constitute essential provisions of this document through normative references. For dated references, only the version corresponding to that date applies to this document. For undated references, the latest version (including all amendments) applies to this document. GB/T1226 General pressure gauge GB2626-2019 Respiratory protection self-priming filter type anti-particulate respirator GB2890-2022 Respiratory protection self-priming filter type gas mask GB/T3836.1 Explosive atmospheres Part 1: General requirements for equipment GB/T3836.4 Explosive atmospheres Part 4: Equipment protected by intrinsic safety type "i" GB/T4208—2017 Degrees of protection provided by enclosures (IP code) GB/T5099.1 Seamless Steel Gas Cylinders Part 1: Steel Cylinders with a Tensile Strength of Less than 1100 MPa After Quenching and Tempering GB/T5099.3 Seamless Steel Gas Cylinders Part 3: Normalized Steel Cylinders GB/T5099.4 Seamless Steel Gas Cylinders Part 4: Stainless Steel Seamless Gas Cylinders GB/T7307—2001 55° Non-Sealing Pipe Thread GB/T12903 Terminology of Personal Protective Equipment GB14866—2023 General Technical Specification for Eye and Face Protective Equipment GB/T23465—2009 Practical Performance Evaluation of Respiratory Protective Equipment GB/T28053 Aluminum Alloy Liner Carbon Fiber Fully Wrapped Gas Cylinders GB31975 Technical Requirements for Respiratory Protection of Compressed Air GB/T32166.2—2015 Personal protective equipment Eye and face protection Occupational eye and face protection Part 2: Measurement methods GB/T34527 Technical requirements for cylinder valves for air breathing apparatus 3 Terms and Definitions The terms and definitions defined in GB/T 12903 and the following apply to this document. 3.1 Self-contained open-circuit compressed air breathing apparatus uses the mask to fit closely around the wearer's face, isolating the wearer's respiratory organs, eyes and face from the outside toxic and harmful air or oxygen-deficient environment. A type of respirator that is completely isolated and requires the personnel to carry their own clean compressed air as the breathing air source, and the exhaled gas is directly discharged into the ambient air. 3.2 Emergency air breathing apparatus self-contained open-circuit compressed air breathing apparatus for fire-fighting andemergencyservices A self-contained open-circuit compressed air breathing apparatus used by workers undertaking emergency tasks such as firefighting, hazardous chemicals disposal, and rescue. 3.3 Industrial air respirator self-contained open-circuit compressed air breathing apparatus for industrial services In addition to the emergency air respirator applicable areas, mining, petrochemical, industry and trade, smelting, transportation, municipal construction, public utilities and other A self-contained open-circuit compressed air respirator used by workers in various industries. 3.4 Static pressure is the pressure inside the mask cavity when the air circuit of the air respirator is balanced after the positive pressure device of the air supply valve is opened. 4 Classification and labeling 4.1 Classification 4.1.1 Classification by applicable occasions According to their applicable occasions, air respirators are divided into: a) industrial air respirators, marking code: GY; b) emergency air respirators, marking code: YJ. 4.1.2 Classification by gas cylinder material According to the type of gas cylinder material, air breathing apparatus are divided into: a) seamless steel gas cylinders, marked with code: G; b) aluminum alloy liner carbon fiber fully wrapped gas cylinders (referred to as "composite gas cylinders"), marked with code: F. 4.1.3 Classification by nominal volume of gas cylinders The nominal volume of the gas cylinder of an air breathing apparatus should be no less than 3 L and no more than 12 L. Gas cylinders may be marked as 3, 4.7, 6.8, 8, 9, 12, etc. according to their actual nominal volume. 4.2 Marking
Contents of GB 16556-2025