GB 16847-1997   Requirements for protective current transformers for transent performance (English Version)
Standard No.: GB 16847-1997 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 11000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:1998-5-1 Delivery: via email in 1 business day

→ → →

,2015-8-3,1998-5-1,14113813346601194F45E986D0612
Standard No.: GB 16847-1997
English Name: Requirements for protective current transformers for transent performance
Chinese Name: 保护用电流互感器暂态特性技术要求
Chinese Classification: K41    Transformer
Professional Classification: GB    National Standard
Source Content Issued by: State Technical Supervision Bureau
Issued on: 1997-07-03
Implemented on: 1998-5-1
Status: superseded
Superseded by:GB 20840.2-2014 Instrument transformers―Part 2:Additional requirements for current transformers
Superseded on:2015-8-3
Target Language: English
File Format: PDF
Word Count: 11000 words
Translation Price(USD): 270.0
Delivery: via email in 1 business day
1 Scope Technical requirements and tests included in this standard is the supplement to Chapter 4 of GB 1208-1997. It is applicable to the electric-magnetic current transformers used for electrical protection system, however such kind of protection system places stress upon requiring that the current transformer is the maintenance of a defined performance up to several times the rated current when the current contains an exponentially decaying d.c. component of defined time constant. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All the standards will be revised, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of the following standards are applicable. GB 1984-89 Alternating Current High-voltage Circuit-breakers (eqv IEC 56: 1987) GB 1208-1997 Current Transformers (eqv IEC 185: 1987)
Foreword II IEC Foreword III IEC Introduction III 1 Scope 2 Normative References 3 Definitions 4 Ratings and Performance Requirements 5 Contents of Specification Appendix A (Normative) Basic Theoretical Equations for Transient Dimensioning Appendix B (Normative) Determination of Core Magnetization Characteristic Appendix C (Normative) Direct Tests Appendix D (Normative) Guide to Performance Criteria for Current Transformer for Protection Relaying Appendix E ( Normative) Determination of Turns Ratio Error
Referred in GB 16847-1997:
* GB 1984-1989 GB/T 4474-1992 GB/T 7675-1987
* GB 1208-1997;GB 20840.2-2014
GB 16847-1997 is referred in:
* GB 3836.3-2010 Explosive atmospheres—Part 3:Equipment protection by increased safety e
* DL/T 5136-2012 Technical code for designing of electrical secondary wiring in fossil fuel power plants and substations
* GB/T 14285-2006 Technical Code for Relaying Protection and Security Automatic Eq
* DL/T 5136-2012 Technical code for designing of electrical secondary wiring in fossil fuel power plants and substations
* GB 3836.3-2010 Explosive atmospheres—Part 3:Equipment protection by increased safety e
* GB 1208-2006 Current Transformers
* GB 1208-2006 Current Transformers
* GB/T 17468-2008 The Guide for Choice Power Transformers
Code of China
Standard
GB 16847-1997  Requirements for protective current transformers for transent performance (English Version)
Standard No.GB 16847-1997
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count11000 words
Price(USD)270.0
Implemented on1998-5-1
Deliveryvia email in 1 business day
Detail of GB 16847-1997
Standard No.
GB 16847-1997
English Name
Requirements for protective current transformers for transent performance
Chinese Name
保护用电流互感器暂态特性技术要求
Chinese Classification
K41
Professional Classification
GB
ICS Classification
Issued by
State Technical Supervision Bureau
Issued on
1997-07-03
Implemented on
1998-5-1
Status
superseded
Superseded by
GB 20840.2-2014 Instrument transformers―Part 2:Additional requirements for current transformers
Superseded on
2015-8-3
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
11000 words
Price(USD)
270.0
Keywords
GB 16847-1997, GB/T 16847-1997, GBT 16847-1997, GB16847-1997, GB 16847, GB16847, GB/T16847-1997, GB/T 16847, GB/T16847, GBT16847-1997, GBT 16847, GBT16847
Introduction of GB 16847-1997
1 Scope Technical requirements and tests included in this standard is the supplement to Chapter 4 of GB 1208-1997. It is applicable to the electric-magnetic current transformers used for electrical protection system, however such kind of protection system places stress upon requiring that the current transformer is the maintenance of a defined performance up to several times the rated current when the current contains an exponentially decaying d.c. component of defined time constant. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All the standards will be revised, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of the following standards are applicable. GB 1984-89 Alternating Current High-voltage Circuit-breakers (eqv IEC 56: 1987) GB 1208-1997 Current Transformers (eqv IEC 185: 1987)
Contents of GB 16847-1997
Foreword II IEC Foreword III IEC Introduction III 1 Scope 2 Normative References 3 Definitions 4 Ratings and Performance Requirements 5 Contents of Specification Appendix A (Normative) Basic Theoretical Equations for Transient Dimensioning Appendix B (Normative) Determination of Core Magnetization Characteristic Appendix C (Normative) Direct Tests Appendix D (Normative) Guide to Performance Criteria for Current Transformer for Protection Relaying Appendix E ( Normative) Determination of Turns Ratio Error
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 16847-1997, GB/T 16847-1997, GBT 16847-1997, GB16847-1997, GB 16847, GB16847, GB/T16847-1997, GB/T 16847, GB/T16847, GBT16847-1997, GBT 16847, GBT16847