2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 17799.8-2023
GB 17799.8-2023   Electromagnetic compatibility (EMC)—Generic standards—Part 8: Emission standard for professional equipment in commercial and light-industrial locations (English Version)
Standard No.: GB 17799.8-2023 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 14500 words Translation Price(USD):435.0 remind me the price change

Email:

Implemented on:2024-7-1 Delivery: via email in 1~3 business day

→ → →

,,2024-7-1,39F840409E1ED7261704205121980
Standard No.: GB 17799.8-2023
English Name: Electromagnetic compatibility (EMC)—Generic standards—Part 8: Emission standard for professional equipment in commercial and light-industrial locations
Chinese Name: 电磁兼容 通用标准 第8部分:商用和轻工业场所专业设备的发射
Chinese Classification: L06    Electromagnetic compatibility
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2023-12-28
Implemented on: 2024-7-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 14500 words
Translation Price(USD): 435.0
Delivery: via email in 1~3 business day
Electromagnetic compatibility (EMC) - Generic standards - Part 8: Emission standard for professional equipment in commercial and light-industrial locations 1 Scope This document is applicable only if no relevant dedicated product or product family EMC emission standard has been published. This document for emission requirements applies to electrical and electronic equipment intended for use in commercial and light-industrial (see 3.1.3) locations. This document applies to equipment that satisfy the following restrictions of use: ——is defined as professional equipment (see 3.1.13), ——is professionally installed and maintained (see 3.1.14 and Clause 6), ——is not intended to be used in residential locations (see 3.1.16). IEC 61000-6-3 applies to electrical and electronic equipment intended for use at commercial and light-industrial locations that do not satisfy these restrictions. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt, the requirements in IEC 61000-6-3 apply. Emission requirements within the frequency range 0 Hz to 400 GHz are covered. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. NOTE 1: Safety considerations are not covered by this document. NOTE 2: In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, employ special mitigation measures to reduce any impact. NOTE 3: Disturbances generated in fault conditions of equipment are not covered by this document. NOTE 4: Equipment which complies with IEC 61000-6-3 are suitable for use within these defined locations. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus (CISPR 16-1-1:2019, IDT) GB/T 6113.104-2021 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements (CISPR 16-1-4:2019, IDT) GB/T 6113.203-2020 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements (CISPR16-2-3:2016, IDT) GB/T 6113.402-2022 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty (CISPR16-4-2:2018, IDT) GB/T 17626.20-2014 Electromagnetic compatibility - Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguide (IEC61000-4-20:2010, IDT) IEC 61000-3-2:2018 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) Note: GB 17625.1-2022, Electromagnetic compatibility – Limits - Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase) (IEC 61000-3-2:2020, MOD) IEC 61000-3-3:2013/ AMD 1: 2017 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection Note: GB/T 17625.2-2007, Electromagnetic compatibility (EMC) - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection (IEC 61000-3-3:2005, IDT) IEC 61000-3-11:2017 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection Note: GB/T 17625.7-2013, Electromagnetic compatibility - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systcms for equipment with rated current ≤ 75 A and subject to conditional connection (IEC 61000-3-11:2000, MOD) IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase Note: GB/T 17625.8-2015, Electromagnetic compatibility - Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A per phase (IEC 61000-3-12:2004, IDT) IEC 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments Note: GB/T 17799.3-2023, Electromagnetic compatibility (EMC) - Generic standards - Part 3: Emission standard for equipment in residential environments (IEC 61000-6-3:2020, IDT) CISPR 16-1-2:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements Note: GB/T 6113.102-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements (CISPR 16-1-2:2014, IDT) CISPR 16-1-5:2014/ AMD 1:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz Note: GB/T 6113.105-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and refernce test sites for 5 MHz to 18 GHz (CISPR 16-1-5:2014, IDT) CISPR 16-1-6:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration Note: GB/T 6113.106-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration (CISPR 16-1-6:2014, IDT) CISPR 16-2-1:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements Note: GB/T 6113.201-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (CISPR 16-2-1:2014, IDT) CISPR 32:2015 Electromagnetic compatibility of multimedia equipment - Emission requirements Note: GB/T 9254.1-2021, Information technology equipment, multimedia equipment and receivers - Electromagnetic compatibility - Part 1: Emission requirements (CISPR 32:2015, MOD) 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: ——IEC Electropedia: available at http://www.electropedia.org/ ——ISO Online browsing platform: available at http://www.iso.org/obp 3.1.1 antenna port port, other than a broadcast receiver tuner port (3.1.2), for connection of an antenna used for intentional transmission and/or reception of radiated RF energy 3.1.2 broadcast receiver tuner port port intended for the reception of a modulated RF signal carrying terrestrial, satellite and/or cable transmissions of audio and/or video broadcast and similar services Note: This port may be connected to an antenna, a cable distribution system, a VCR or similar device. 3.1.3 commercial and light-industrial location location which are not residential in accordance with 3.1.16, where the mains supply is directly connected to the low-voltage public network or connected to a dedicated DC source which is intended to interface between the equipment and the low-voltage public mains network. Note 1: Examples of commercial or light-industrial locations are: ——retail outlets, ——business premises, ——areas of public entertainment, ——places of worship, ——outdoor locations, ——general public locations, ——hospitals, educational institutions,
Code of China
Standard
GB 17799.8-2023  Electromagnetic compatibility (EMC)—Generic standards—Part 8: Emission standard for professional equipment in commercial and light-industrial locations (English Version)
Standard No.GB 17799.8-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count14500 words
Price(USD)435.0
Implemented on2024-7-1
Deliveryvia email in 1~3 business day
Detail of GB 17799.8-2023
Standard No.
GB 17799.8-2023
English Name
Electromagnetic compatibility (EMC)—Generic standards—Part 8: Emission standard for professional equipment in commercial and light-industrial locations
Chinese Name
电磁兼容 通用标准 第8部分:商用和轻工业场所专业设备的发射
Chinese Classification
L06
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2023-12-28
Implemented on
2024-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
14500 words
Price(USD)
435.0
Keywords
GB 17799.8-2023, GB/T 17799.8-2023, GBT 17799.8-2023, GB17799.8-2023, GB 17799.8, GB17799.8, GB/T17799.8-2023, GB/T 17799.8, GB/T17799.8, GBT17799.8-2023, GBT 17799.8, GBT17799.8
Introduction of GB 17799.8-2023
Electromagnetic compatibility (EMC) - Generic standards - Part 8: Emission standard for professional equipment in commercial and light-industrial locations 1 Scope This document is applicable only if no relevant dedicated product or product family EMC emission standard has been published. This document for emission requirements applies to electrical and electronic equipment intended for use in commercial and light-industrial (see 3.1.3) locations. This document applies to equipment that satisfy the following restrictions of use: ——is defined as professional equipment (see 3.1.13), ——is professionally installed and maintained (see 3.1.14 and Clause 6), ——is not intended to be used in residential locations (see 3.1.16). IEC 61000-6-3 applies to electrical and electronic equipment intended for use at commercial and light-industrial locations that do not satisfy these restrictions. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt, the requirements in IEC 61000-6-3 apply. Emission requirements within the frequency range 0 Hz to 400 GHz are covered. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. NOTE 1: Safety considerations are not covered by this document. NOTE 2: In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, employ special mitigation measures to reduce any impact. NOTE 3: Disturbances generated in fault conditions of equipment are not covered by this document. NOTE 4: Equipment which complies with IEC 61000-6-3 are suitable for use within these defined locations. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus (CISPR 16-1-1:2019, IDT) GB/T 6113.104-2021 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements (CISPR 16-1-4:2019, IDT) GB/T 6113.203-2020 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements (CISPR16-2-3:2016, IDT) GB/T 6113.402-2022 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty (CISPR16-4-2:2018, IDT) GB/T 17626.20-2014 Electromagnetic compatibility - Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguide (IEC61000-4-20:2010, IDT) IEC 61000-3-2:2018 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) Note: GB 17625.1-2022, Electromagnetic compatibility – Limits - Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase) (IEC 61000-3-2:2020, MOD) IEC 61000-3-3:2013/ AMD 1: 2017 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection Note: GB/T 17625.2-2007, Electromagnetic compatibility (EMC) - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection (IEC 61000-3-3:2005, IDT) IEC 61000-3-11:2017 Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection Note: GB/T 17625.7-2013, Electromagnetic compatibility - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systcms for equipment with rated current ≤ 75 A and subject to conditional connection (IEC 61000-3-11:2000, MOD) IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and ≤ 75 A per phase Note: GB/T 17625.8-2015, Electromagnetic compatibility - Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤75 A per phase (IEC 61000-3-12:2004, IDT) IEC 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments Note: GB/T 17799.3-2023, Electromagnetic compatibility (EMC) - Generic standards - Part 3: Emission standard for equipment in residential environments (IEC 61000-6-3:2020, IDT) CISPR 16-1-2:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements Note: GB/T 6113.102-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements (CISPR 16-1-2:2014, IDT) CISPR 16-1-5:2014/ AMD 1:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz Note: GB/T 6113.105-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and refernce test sites for 5 MHz to 18 GHz (CISPR 16-1-5:2014, IDT) CISPR 16-1-6:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration Note: GB/T 6113.106-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-6: Radio disturbance and immunity measuring apparatus - EMC antenna calibration (CISPR 16-1-6:2014, IDT) CISPR 16-2-1:2014/ AMD 1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements Note: GB/T 6113.201-2018, Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (CISPR 16-2-1:2014, IDT) CISPR 32:2015 Electromagnetic compatibility of multimedia equipment - Emission requirements Note: GB/T 9254.1-2021, Information technology equipment, multimedia equipment and receivers - Electromagnetic compatibility - Part 1: Emission requirements (CISPR 32:2015, MOD) 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: ——IEC Electropedia: available at http://www.electropedia.org/ ——ISO Online browsing platform: available at http://www.iso.org/obp 3.1.1 antenna port port, other than a broadcast receiver tuner port (3.1.2), for connection of an antenna used for intentional transmission and/or reception of radiated RF energy 3.1.2 broadcast receiver tuner port port intended for the reception of a modulated RF signal carrying terrestrial, satellite and/or cable transmissions of audio and/or video broadcast and similar services Note: This port may be connected to an antenna, a cable distribution system, a VCR or similar device. 3.1.3 commercial and light-industrial location location which are not residential in accordance with 3.1.16, where the mains supply is directly connected to the low-voltage public network or connected to a dedicated DC source which is intended to interface between the equipment and the low-voltage public mains network. Note 1: Examples of commercial or light-industrial locations are: ——retail outlets, ——business premises, ——areas of public entertainment, ——places of worship, ——outdoor locations, ——general public locations, ——hospitals, educational institutions,
Contents of GB 17799.8-2023
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 17799.8-2023, GB/T 17799.8-2023, GBT 17799.8-2023, GB17799.8-2023, GB 17799.8, GB17799.8, GB/T17799.8-2023, GB/T 17799.8, GB/T17799.8, GBT17799.8-2023, GBT 17799.8, GBT17799.8