2026-1-20 10.1.194.235
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 22448-2025
GB 22448-2025   Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV (English Version)
Standard No.: GB 22448-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):210.0 remind me the price change

Email:

Implemented on:2026-8-1 Delivery: via email in 1~3 business day

→ → →

,,2026-8-1,C1FBF65BB026FE551754293691997
Standard No.: GB 22448-2025
English Name: Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV
Chinese Name: 无损检测仪器 500kV以下工业X射线探伤机防护规则
Chinese Classification: N78    X ray, magnetic powder, fluorescent light and other defectoscope
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-08-01
Implemented on: 2026-8-1
Status: to be valid
Superseding:GB 22448-2008 Protection rules for industrial X-ray radiographic equipment up to 500kV
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 210.0
Delivery: via email in 1~3 business day
GB 22448-2025 Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 19.100 CCS N 78 National Standard of the People's Republic of China GB 22448-2025 Replaces GB 22448-2008 Non-destructive testing instruments - Protection rules for industrial X-ray radiographic equipment below 500kV 无损检测仪器 500kV以下工业X射线 探伤机防护规则 (English Translation) Issue date: 2025-08-01 Implementation date: 2026-08-01 Issued by the State Administration for Market Regulation the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Protection requirements for X-ray machines 5 Protection requirements for X-ray radiographic operation sites 6 X-ray protection monitoring during use 7 Safe operation requirements for X-ray machines 8 Radiation protection detection of X-ray machines Non-destructive testing instruments - Protection rules for industrial X-ray radiographic equipment below 500kV 1 Scope This document specifies the protection requirements for industrial X-ray radiographic equipment below 500kV, protection requirements for X-ray radiographic operation sites, radiation protection monitoring during use, safe operation requirements for X-ray machines, and radiation protection detection of X-ray machines, etc. This document is applicable to the design, manufacture, installation and use of industrial X-ray radiographic equipment below 500kV (including fixed X-ray radiographic machines, mobile X-ray radiographic machines and portable X-ray radiographic machines). Non-radiographic non-destructive testing equipment within the same radiation source range shall be used as a reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18871 Basic standards for protection against ionizing radiation and for the safety of radiation sources GB/T 36416.2 Testing machine vocabulary - Part2 : Non-destructive testing instruments 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 18871 and GB/T 36416.2 and the following apply. 4 Protection requirements for X-ray machines 4.1 Ambient dose equivalent rate caused by leakage radiation from X-ray machines When the industrial X-ray radiographic equipment below 500kV (hereinafter referred to as “X-ray machine”) is in operation, the main beam window of the X-ray tube shall be covered with a light shield. At the maximum working value specified by the manufacturer, the ambient dose equivalent rate caused by leakage radiation at 100cm from the focal point of the X-ray tube shall be measured with a protective level dosimeter, and the measured results shall meet the requirements in Table 1. 4.2 X-ray tube 4.2.1 The X-ray tube shall be fixable in any required position and locked. 4.2.2 The X-ray tube shall be equipped with a beam limiting device. 4.2.3 The aperture of the X-ray tube window shall be less than or equal to the size required for the emission of the rated maximum useful beam. 4.2.4 The X-ray tube shall be marked with the following: a) Manufacturer’s name or trademark; b) Model and serial number; c) Rated tube voltage and tube power of the X-ray tube; d) Focal position; e) Date of manufacture; f) Ionizing radiation symbol. 4.3 Controller 4.3.1 The controller shall ensure that it cannot be started without permission. 4.3.2 Operation marks related to protective performance shall be clearly indicated. 4.3.3 The controller shall play a safety protection role when the X-ray machine is started. 4.3.4 When the X-ray machine is in operation, the warning yellow light or voice control device configured on the controller shall work normally. 4.3.5 An emergency stop switch shall be provided. 4.3.6 A key switch shall be provided. The X-ray tube can only emit radiation after turning on the console key switch. The key can only be pulled out when the machine is stopped or in standby state. 4.4 X-ray generator It shall be ensured that the controller can only issue emission instructions when the X-ray generator is connected. When the X-ray generator is disconnected, no X-ray shall be emitted. The connection status of the X-ray generator shall not be changed at will. 4.5 Shielding Material The thickness of the shielding material inside the X-ray tube shall meet the requirements for the ambient dose equivalent rate caused by leakage radiation in 4.1. 4.6 Connecting Cable The length of the connecting cable between the controller and the high-voltage generator of the portable X-ray machine shall be greater than or equal to 20m. 4.7 X-ray protection facilities 4.7.1 It shall be ensured that the X-ray generator is disconnected before opening the X-ray protection facilities to prevent the escape of effective X-ray beam radiation. When the X-ray protection facilities are in the protective state, there shall be no leakage radiation of X-rays. 4.7.2 A door-machine interlocking device shall be installed on the protection facilities. When the interlocking device is opened, it shall ensure no voltage output. 5 Protection requirements for X-ray radiographic operation sites 5.1 Protection of X-ray inspection room 5.1.1 The radiographic room shall be separated from the operation room to ensure radiation safety around. 5.1.2 The shielding design of the radiographic room shall ensure that the annual effective dose of operators is less than the corresponding limit. The reference control level of the ambient dose equivalent rate at 30cm outside the shielding body shall be less than or equal to 2.5μSv/h. For the outer surface of the top of the radiographic room where no personnel can reach, the reference control level of the ambient dose equivalent rate at 30cm can usually be 100μSv/h. Note: The reference contents for the design of the shielding body of the radiographic room include the direction and range of useful beam irradiation, the working load of the device and the outdoor conditions, etc. 5.1.3 The protective performance of the door of the radiographic room shall be the same as that of the wall on the same side. A door-machine interlocking safety device and an irradiation signal indicator shall be installed to ensure that the radiography inspection can be carried out only after the door is closed. 5.1.4 An emergency stop switch shall be equipped in the radiographic room. 5.1.5 A ventilation device shall be equipped in the radiographic room. 5.1.6 A safety protection monitoring device shall be installed in the radiographic room. 5.2 On-site X-ray Radiographic Operation During on-site radiography inspection, appropriate protective measures shall be taken according to factors such as the distance between the controller and the X-ray tube and the inspected object, irradiation direction, irradiation time and shielding conditions to ensure that the radiation dose of radiographic operators is lower than the dose limit. 6 X-ray protection monitoring during use 6.1 Occupational exposure dose limits Routine personal dose monitoring shall be carried out for occupational exposure personnel, and personal dose and health management files shall be established. The monitoring values shall meet the requirements of GB 18871, including the following contents: a) Annual average effective dose for 5 consecutive years; b) Effective dose in any one year; c) Annual effective dose to the lens of the eye; d) Annual equivalent dose to the extremities (hands and feet) or skin.
Code of China
Standard
GB 22448-2025  Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV (English Version)
Standard No.GB 22448-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)210.0
Implemented on2026-8-1
Deliveryvia email in 1~3 business day
Detail of GB 22448-2025
Standard No.
GB 22448-2025
English Name
Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV
Chinese Name
无损检测仪器 500kV以下工业X射线探伤机防护规则
Chinese Classification
N78
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-08-01
Implemented on
2026-8-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 22448-2008 Protection rules for industrial X-ray radiographic equipment up to 500kV
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
210.0
Keywords
GB 22448-2025, GB/T 22448-2025, GBT 22448-2025, GB22448-2025, GB 22448, GB22448, GB/T22448-2025, GB/T 22448, GB/T22448, GBT22448-2025, GBT 22448, GBT22448
Introduction of GB 22448-2025
GB 22448-2025 Non-destructive testing instruments—Protection rules for industrial X-ray radiographic equipment below 500kV English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 19.100 CCS N 78 National Standard of the People's Republic of China GB 22448-2025 Replaces GB 22448-2008 Non-destructive testing instruments - Protection rules for industrial X-ray radiographic equipment below 500kV 无损检测仪器 500kV以下工业X射线 探伤机防护规则 (English Translation) Issue date: 2025-08-01 Implementation date: 2026-08-01 Issued by the State Administration for Market Regulation the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Protection requirements for X-ray machines 5 Protection requirements for X-ray radiographic operation sites 6 X-ray protection monitoring during use 7 Safe operation requirements for X-ray machines 8 Radiation protection detection of X-ray machines Non-destructive testing instruments - Protection rules for industrial X-ray radiographic equipment below 500kV 1 Scope This document specifies the protection requirements for industrial X-ray radiographic equipment below 500kV, protection requirements for X-ray radiographic operation sites, radiation protection monitoring during use, safe operation requirements for X-ray machines, and radiation protection detection of X-ray machines, etc. This document is applicable to the design, manufacture, installation and use of industrial X-ray radiographic equipment below 500kV (including fixed X-ray radiographic machines, mobile X-ray radiographic machines and portable X-ray radiographic machines). Non-radiographic non-destructive testing equipment within the same radiation source range shall be used as a reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 18871 Basic standards for protection against ionizing radiation and for the safety of radiation sources GB/T 36416.2 Testing machine vocabulary - Part2 : Non-destructive testing instruments 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 18871 and GB/T 36416.2 and the following apply. 4 Protection requirements for X-ray machines 4.1 Ambient dose equivalent rate caused by leakage radiation from X-ray machines When the industrial X-ray radiographic equipment below 500kV (hereinafter referred to as “X-ray machine”) is in operation, the main beam window of the X-ray tube shall be covered with a light shield. At the maximum working value specified by the manufacturer, the ambient dose equivalent rate caused by leakage radiation at 100cm from the focal point of the X-ray tube shall be measured with a protective level dosimeter, and the measured results shall meet the requirements in Table 1. 4.2 X-ray tube 4.2.1 The X-ray tube shall be fixable in any required position and locked. 4.2.2 The X-ray tube shall be equipped with a beam limiting device. 4.2.3 The aperture of the X-ray tube window shall be less than or equal to the size required for the emission of the rated maximum useful beam. 4.2.4 The X-ray tube shall be marked with the following: a) Manufacturer’s name or trademark; b) Model and serial number; c) Rated tube voltage and tube power of the X-ray tube; d) Focal position; e) Date of manufacture; f) Ionizing radiation symbol. 4.3 Controller 4.3.1 The controller shall ensure that it cannot be started without permission. 4.3.2 Operation marks related to protective performance shall be clearly indicated. 4.3.3 The controller shall play a safety protection role when the X-ray machine is started. 4.3.4 When the X-ray machine is in operation, the warning yellow light or voice control device configured on the controller shall work normally. 4.3.5 An emergency stop switch shall be provided. 4.3.6 A key switch shall be provided. The X-ray tube can only emit radiation after turning on the console key switch. The key can only be pulled out when the machine is stopped or in standby state. 4.4 X-ray generator It shall be ensured that the controller can only issue emission instructions when the X-ray generator is connected. When the X-ray generator is disconnected, no X-ray shall be emitted. The connection status of the X-ray generator shall not be changed at will. 4.5 Shielding Material The thickness of the shielding material inside the X-ray tube shall meet the requirements for the ambient dose equivalent rate caused by leakage radiation in 4.1. 4.6 Connecting Cable The length of the connecting cable between the controller and the high-voltage generator of the portable X-ray machine shall be greater than or equal to 20m. 4.7 X-ray protection facilities 4.7.1 It shall be ensured that the X-ray generator is disconnected before opening the X-ray protection facilities to prevent the escape of effective X-ray beam radiation. When the X-ray protection facilities are in the protective state, there shall be no leakage radiation of X-rays. 4.7.2 A door-machine interlocking device shall be installed on the protection facilities. When the interlocking device is opened, it shall ensure no voltage output. 5 Protection requirements for X-ray radiographic operation sites 5.1 Protection of X-ray inspection room 5.1.1 The radiographic room shall be separated from the operation room to ensure radiation safety around. 5.1.2 The shielding design of the radiographic room shall ensure that the annual effective dose of operators is less than the corresponding limit. The reference control level of the ambient dose equivalent rate at 30cm outside the shielding body shall be less than or equal to 2.5μSv/h. For the outer surface of the top of the radiographic room where no personnel can reach, the reference control level of the ambient dose equivalent rate at 30cm can usually be 100μSv/h. Note: The reference contents for the design of the shielding body of the radiographic room include the direction and range of useful beam irradiation, the working load of the device and the outdoor conditions, etc. 5.1.3 The protective performance of the door of the radiographic room shall be the same as that of the wall on the same side. A door-machine interlocking safety device and an irradiation signal indicator shall be installed to ensure that the radiography inspection can be carried out only after the door is closed. 5.1.4 An emergency stop switch shall be equipped in the radiographic room. 5.1.5 A ventilation device shall be equipped in the radiographic room. 5.1.6 A safety protection monitoring device shall be installed in the radiographic room. 5.2 On-site X-ray Radiographic Operation During on-site radiography inspection, appropriate protective measures shall be taken according to factors such as the distance between the controller and the X-ray tube and the inspected object, irradiation direction, irradiation time and shielding conditions to ensure that the radiation dose of radiographic operators is lower than the dose limit. 6 X-ray protection monitoring during use 6.1 Occupational exposure dose limits Routine personal dose monitoring shall be carried out for occupational exposure personnel, and personal dose and health management files shall be established. The monitoring values shall meet the requirements of GB 18871, including the following contents: a) Annual average effective dose for 5 consecutive years; b) Effective dose in any one year; c) Annual effective dose to the lens of the eye; d) Annual equivalent dose to the extremities (hands and feet) or skin.
Contents of GB 22448-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 22448-2025, GB/T 22448-2025, GBT 22448-2025, GB22448-2025, GB 22448, GB22448, GB/T22448-2025, GB/T 22448, GB/T22448, GBT22448-2025, GBT 22448, GBT22448