2026-4-11 10.1.51.168
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 25204-2026
GB 25204-2026   Auto tracking and targeting jet suppression system (English Version)
Standard No.: GB 25204-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):300.0 remind me the price change

Email:

Implemented on:2027-3-1 Delivery: via email in 1~5 business day

→ → →

,,2027-3-1,905B986B0F4EEEAC1772758277680
Standard No.: GB 25204-2026
English Name: Auto tracking and targeting jet suppression system
Chinese Name: 自动跟踪定位射流灭火系统
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2026-02-27
Implemented on: 2027-3-1
Status: to be valid
Superseding:GB 25204-2010 Auto tracking and targeting jet suppression system
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 300.0
Delivery: via email in 1~5 business day
GB 25204-2026 Auto tracking and targeting jet suppression system English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 25204-2026 Auto tracking and targeting jet suppression system 自动跟踪定位射流灭火系统 Issue date: 2026-02-27 Implementation date: 2027-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Model Designation 4.1 Classification 4.2 Classification by Flow Rate for Auto Tracking and Targeting Jet Suppression Systems 4.3 Classification by Jet Mode for Auto Tracking and Targeting Jet Suppression Devices 4.4 Model Designation 5 Performance Requirements 5.1 Requirements for Fire Suppression Devices 5.2 Power Supply Requirements 5.3 On-Site Video Archiving Requirements 5.4 System Operational Reliability 5.5 Control System Requirements 5.6 Detection Component Requirements 5.7 Fire Suppression Component Requirements 5.8 Fire Fluid Supply Requirements for the System 6 Test Methods 6.1 Fire Suppression Device Test 6.2 Power Supply Test 6.3 On-Site Video Archiving Test 6.4 System Operational Reliability Test 6.5 Control System Test 6.6 Detection Component Test 6.7 Fire Suppression Component Inspection 6.8 Fire Fluid Supply Test for the System 7 Inspection Rules 7.1 Factory Inspection 7.2 Type Test 8 Marking, Packaging, Storage, Transport, and Instruction Manual 8.1 Marking 8.2 Packaging 8.3 Storage Auto Tracking and Targeting Jet Suppression System 1 Scope This document defines the terms and definitions for auto tracking and targeting jet suppression systems (hereinafter referred to as the "system"); specifies the system classification and model designation, performance requirements, inspection rules, as well as marking, packaging, storage, transport, and instruction manual; and describes the test methods for the system. This document applies to various indoor and outdoor auto tracking and targeting jet suppression systems. 2 Normative References The following documents contain provisions which, through normative reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2423.1—2008 Environmental testing for electric and electronic products — Part 2: Test methods — Test A: Cold GB/T 2423.2—2008 Environmental testing for electric and electronic products — Part 2: Test methods — Test B: Dry heat GB/T 2423.3—2016 Environmental testing — Part 2: Test methods — Test Cab: Damp heat, steady state GB/T 3836.1 Explosive atmospheres — Part 1: Equipment — General requirements GB/T 3836.2 Explosive atmospheres — Part 2: Equipment protection by flameproof enclosures "d" GB 4351—2023 Portable fire extinguishers GB/T 17626.2 Electromagnetic compatibility — Testing and measurement techniques — Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility — Testing and measurement techniques — Part 3: Radiated, radio-frequency, electromagnetic field immunity test GB/T 17626.4 Electromagnetic compatibility — Testing and measurement techniques — Electrical fast transient/burst immunity test GB/T 17626.5 Electromagnetic compatibility — Testing and measurement techniques — Surge immunity test GB/T 17626.6 Electromagnetic compatibility — Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields GB 19156 Fire monitor 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 auto tracking and targeting jet suppression system Various indoor and outdoor fixed jet suppression devices that utilize UV-sensitive components, IR-sensitive components, imaging devices, thermal imaging devices, or other fire detection components to detect incipient fires, automatically track and target them, and achieve extinguishment through automatic control methods. NOTE 1: The system consists of a fire suppression device with detection components and automatic control parts (hereinafter referred to as the "fire suppression device") and a fire fluid supply part. NOTE 2: Fire suppression devices are classified into auto tracking and targeting fire monitor suppression devices, jet-type auto tracking and targeting jet suppression devices, and spray-type auto tracking and targeting jet suppression devices. NOTE 3: The fire suppression component is the part of the fire suppression device that discharges the extinguishing medium. 3.2 targeting time The time from when the test fire starts to burn until the system begins to discharge the extinguishing medium. 3.3 protection radius For an auto tracking and targeting fire monitor suppression device or a jet-type auto tracking and targeting jet suppression device, the distance from the fire suppression component to the effective range of the jet; for a spray-type auto tracking and targeting jet suppression device, the distance from the center of the circular projection on the ground of the effective spray coverage to its circumference. 3.4 rated working pressure The rated pressure at the inlet of the fire suppression component. 3.5 rated flow The flow rate of the fire suppression component at the rated working pressure. 3.6 local controller A system component for local control and information processing, having the functions of receiving and timely processing fire detection signals, issuing control and alarm information, driving the fire suppression component to target and extinguish the fire, receiving feedback signals, while simultaneously completing corresponding display and recording, and transmitting signals to a fire alarm control unit or a fire linkage control unit. 3.7 centralized controller A system component for remote control and information processing, having the functions of receiving and timely processing fire detection signals, issuing control and alarm information, driving the fire suppression component to target and extinguish the fire, receiving feedback signals, while simultaneously completing corresponding display and recording, and transmitting signals to a fire alarm control unit or a fire linkage control unit. 4 Classification and Model Designation 4.1 Classification Auto tracking and targeting jet suppression systems shall be classified according to flow rate and jet mode. 4.2 Classification by Flow Rate for Auto Tracking and Targeting Jet Suppression Systems Classified by flow rate as: a) Auto tracking and targeting fire monitor suppression devices, with a rated flow greater than 16 L/s; b) Auto tracking and targeting jet suppression devices, with a rated flow not greater than 16 L/s. 4.3 Classification by Jet Mode for Auto Tracking and Targeting Jet Suppression Devices Classified by jet mode as: a) Jet-type auto tracking and targeting jet suppression devices, where the jet mode is jetting; b) Spray-type auto tracking and targeting jet suppression devices, where the jet mode is spraying. 4.4 Model Designation 4.4.1 Rules for Model Designation The model designation for auto tracking and targeting jet suppression systems shall consist of the system name, characteristic code, rated working pressure, rated flow, jet medium code, start-up control component code, targeting detection component code, flameproof code, and user-defined part. The rules for designation are shown in Figure 1.
Code of China
Standard
GB 25204-2026  Auto tracking and targeting jet suppression system (English Version)
Standard No.GB 25204-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)300.0
Implemented on2027-3-1
Deliveryvia email in 1~5 business day
Detail of GB 25204-2026
Standard No.
GB 25204-2026
English Name
Auto tracking and targeting jet suppression system
Chinese Name
自动跟踪定位射流灭火系统
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2026-02-27
Implemented on
2027-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 25204-2010 Auto tracking and targeting jet suppression system
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
300.0
Keywords
GB 25204-2026, GB/T 25204-2026, GBT 25204-2026, GB25204-2026, GB 25204, GB25204, GB/T25204-2026, GB/T 25204, GB/T25204, GBT25204-2026, GBT 25204, GBT25204
Introduction of GB 25204-2026
GB 25204-2026 Auto tracking and targeting jet suppression system English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 25204-2026 Auto tracking and targeting jet suppression system 自动跟踪定位射流灭火系统 Issue date: 2026-02-27 Implementation date: 2027-03-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Model Designation 4.1 Classification 4.2 Classification by Flow Rate for Auto Tracking and Targeting Jet Suppression Systems 4.3 Classification by Jet Mode for Auto Tracking and Targeting Jet Suppression Devices 4.4 Model Designation 5 Performance Requirements 5.1 Requirements for Fire Suppression Devices 5.2 Power Supply Requirements 5.3 On-Site Video Archiving Requirements 5.4 System Operational Reliability 5.5 Control System Requirements 5.6 Detection Component Requirements 5.7 Fire Suppression Component Requirements 5.8 Fire Fluid Supply Requirements for the System 6 Test Methods 6.1 Fire Suppression Device Test 6.2 Power Supply Test 6.3 On-Site Video Archiving Test 6.4 System Operational Reliability Test 6.5 Control System Test 6.6 Detection Component Test 6.7 Fire Suppression Component Inspection 6.8 Fire Fluid Supply Test for the System 7 Inspection Rules 7.1 Factory Inspection 7.2 Type Test 8 Marking, Packaging, Storage, Transport, and Instruction Manual 8.1 Marking 8.2 Packaging 8.3 Storage Auto Tracking and Targeting Jet Suppression System 1 Scope This document defines the terms and definitions for auto tracking and targeting jet suppression systems (hereinafter referred to as the "system"); specifies the system classification and model designation, performance requirements, inspection rules, as well as marking, packaging, storage, transport, and instruction manual; and describes the test methods for the system. This document applies to various indoor and outdoor auto tracking and targeting jet suppression systems. 2 Normative References The following documents contain provisions which, through normative reference in this text, constitute essential provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2423.1—2008 Environmental testing for electric and electronic products — Part 2: Test methods — Test A: Cold GB/T 2423.2—2008 Environmental testing for electric and electronic products — Part 2: Test methods — Test B: Dry heat GB/T 2423.3—2016 Environmental testing — Part 2: Test methods — Test Cab: Damp heat, steady state GB/T 3836.1 Explosive atmospheres — Part 1: Equipment — General requirements GB/T 3836.2 Explosive atmospheres — Part 2: Equipment protection by flameproof enclosures "d" GB 4351—2023 Portable fire extinguishers GB/T 17626.2 Electromagnetic compatibility — Testing and measurement techniques — Electrostatic discharge immunity test GB/T 17626.3 Electromagnetic compatibility — Testing and measurement techniques — Part 3: Radiated, radio-frequency, electromagnetic field immunity test GB/T 17626.4 Electromagnetic compatibility — Testing and measurement techniques — Electrical fast transient/burst immunity test GB/T 17626.5 Electromagnetic compatibility — Testing and measurement techniques — Surge immunity test GB/T 17626.6 Electromagnetic compatibility — Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields GB 19156 Fire monitor 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 auto tracking and targeting jet suppression system Various indoor and outdoor fixed jet suppression devices that utilize UV-sensitive components, IR-sensitive components, imaging devices, thermal imaging devices, or other fire detection components to detect incipient fires, automatically track and target them, and achieve extinguishment through automatic control methods. NOTE 1: The system consists of a fire suppression device with detection components and automatic control parts (hereinafter referred to as the "fire suppression device") and a fire fluid supply part. NOTE 2: Fire suppression devices are classified into auto tracking and targeting fire monitor suppression devices, jet-type auto tracking and targeting jet suppression devices, and spray-type auto tracking and targeting jet suppression devices. NOTE 3: The fire suppression component is the part of the fire suppression device that discharges the extinguishing medium. 3.2 targeting time The time from when the test fire starts to burn until the system begins to discharge the extinguishing medium. 3.3 protection radius For an auto tracking and targeting fire monitor suppression device or a jet-type auto tracking and targeting jet suppression device, the distance from the fire suppression component to the effective range of the jet; for a spray-type auto tracking and targeting jet suppression device, the distance from the center of the circular projection on the ground of the effective spray coverage to its circumference. 3.4 rated working pressure The rated pressure at the inlet of the fire suppression component. 3.5 rated flow The flow rate of the fire suppression component at the rated working pressure. 3.6 local controller A system component for local control and information processing, having the functions of receiving and timely processing fire detection signals, issuing control and alarm information, driving the fire suppression component to target and extinguish the fire, receiving feedback signals, while simultaneously completing corresponding display and recording, and transmitting signals to a fire alarm control unit or a fire linkage control unit. 3.7 centralized controller A system component for remote control and information processing, having the functions of receiving and timely processing fire detection signals, issuing control and alarm information, driving the fire suppression component to target and extinguish the fire, receiving feedback signals, while simultaneously completing corresponding display and recording, and transmitting signals to a fire alarm control unit or a fire linkage control unit. 4 Classification and Model Designation 4.1 Classification Auto tracking and targeting jet suppression systems shall be classified according to flow rate and jet mode. 4.2 Classification by Flow Rate for Auto Tracking and Targeting Jet Suppression Systems Classified by flow rate as: a) Auto tracking and targeting fire monitor suppression devices, with a rated flow greater than 16 L/s; b) Auto tracking and targeting jet suppression devices, with a rated flow not greater than 16 L/s. 4.3 Classification by Jet Mode for Auto Tracking and Targeting Jet Suppression Devices Classified by jet mode as: a) Jet-type auto tracking and targeting jet suppression devices, where the jet mode is jetting; b) Spray-type auto tracking and targeting jet suppression devices, where the jet mode is spraying. 4.4 Model Designation 4.4.1 Rules for Model Designation The model designation for auto tracking and targeting jet suppression systems shall consist of the system name, characteristic code, rated working pressure, rated flow, jet medium code, start-up control component code, targeting detection component code, flameproof code, and user-defined part. The rules for designation are shown in Figure 1.
Contents of GB 25204-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 25204-2026, GB/T 25204-2026, GBT 25204-2026, GB25204-2026, GB 25204, GB25204, GB/T25204-2026, GB/T 25204, GB/T25204, GBT25204-2026, GBT 25204, GBT25204