2025-12-27 10.8.118.215
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 29539-2025
GB 29539-2025   Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans (English Version)
Standard No.: GB 29539-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 11500 words Translation Price(USD):300.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1 business day

→ → →

,,2026-11-1,266829609C0B15721762263306854
Standard No.: GB 29539-2025
English Name: Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans
Chinese Name: 家用和类似用途吸油烟机与换气扇能效限定值及能效等级
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-11-1
Status: to be valid
Superseding:GB 29539-2013 Minimum allowable values of energy efficiency and energy efficiency grades for range hoods
GB 32049-2015 Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans
Target Language: English
File Format: PDF
Word Count: 11500 words
Translation Price(USD): 300.0
Delivery: via email in 1 business day
GB 29539-2025 Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans 1 Scope This document specifies the grades of energy efficiency. minimum allowable values, test methods and standard implementation for the household and similar range hoods, electric ventilating fans, and multifunctional appliances with ventilating function. This document is applicable to: a) Air-extraction range hoods installed on the upper part of household cooking stoves, stoves or similar appliances, with a rated voltage not more than 250 V; b) Ventilating fans driven by electric motors, with single-phase rated voltage not more than 250 V, rated ventilating input power not more than 500 W, impeller diameter not more than 500 mm, as well as multifunctional appliances with ventilating function. This document is not applicable to: a) Cooking fume suction and extraction device of a downdraft system; b) Commercial range hoods, and other commercial cooking fume extractors; c) Ventilating fans designed exclusively for industrial purposes; d) Ventilating fans intended for use under special conditions, such as where corrosive, flammable and explosive gases, dust, steam or gas are present; e) Ventilating fans for refrigeration equipment or air conditioners and air-to-air energy recovery devices; f) Ventilating fans embedded in appliances (such as stoves and microwave cooking appliances); g) Marine ventilating fans; h) Type C ventilating fans, two-way outlet ventilating fans, and Types B and D ventilating fans with a maximum static pressure of less than 25 Pa; i) Ventilating fans with filter screens and a fresh air PM2.5 filtration efficiency greater than 90% tested according to GB/T 34012-2017. Note: The definitions of types A, B, C, D ventilating fans and the like are quoted from GB/T 14806-2017. 2 Normative References The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 14806-2017 A.C. electric ventilating fans and regulators for household and similar purposes GB/T 17713-2022 Range hoods, and other cooking fume extractors GB/T 22769-2023 Electric bathroom heater (Yuba) GB/T 34012-2017 Air cleaner for ventilation system GB/T 35758-2017 Household electrical appliances - Measurement of standby power 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 14806-2017, GB/T 17713-2022, GB/T 22769-2023 and GB/T 35758-2017, as well as the following apply. 3.1 minimum allowable values of energy efficiency for range hoods minimum allowable values of energy efficiency for range hoods under the specified test conditions 3.2 minimum allowable values of energy efficiency for ventilating fans minimum allowable values of energy efficiency for ventilating fans under the test conditions specified in the standard 3.3 standby mode continuous mode for any product, in which a range hood or ventilating fan provides one or more of the following user-oriented functions or protection functions when connected to the main power: —— other modes (including main function on or off) may be triggered by triggering remote switches (including non-contract mode for the appliance), internal sensors and timers; —— continuous function: information or status display including clock; —— continuous function: sensor-based function. [Source: GB/T 35758-2017, 3.6, modified]
Contents Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical requirements 5 Test method 6 Implementation of the standard Annex A (Normative) Total pressure efficiency at working airflow Annex B (Normative) Standby/off power test method Annex C (Normative) Test method for heating energy consumption of bathroom heater Annex D (Normative) Test method for energy efficiency of ventilating fans
Referred in GB 29539-2025:
*GB/T 14806-2017 A.C.electric ventilating fans andregulators for household and similar purposes
*GB/T 17713-2022 Range hoods and other cooking fume extractors
*GB/T 22769-2023 Electric bathroom heater(Yuba)
*GB/T 34012-2017 Air cleaner for ventilation system
*GB/T 35758-2017 Household electrical appliances―Measurement of standby power
Code of China
Standard
GB 29539-2025  Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans (English Version)
Standard No.GB 29539-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count11500 words
Price(USD)300.0
Implemented on2026-11-1
Deliveryvia email in 1 business day
Detail of GB 29539-2025
Standard No.
GB 29539-2025
English Name
Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans
Chinese Name
家用和类似用途吸油烟机与换气扇能效限定值及能效等级
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 29539-2013 Minimum allowable values of energy efficiency and energy efficiency grades for range hoods
GB 32049-2015 Minimum allowable values of energy efficiency and energy efficiency grades for household and similar purposes A.C. electric ventilating fans
Language
English
File Format
PDF
Word Count
11500 words
Price(USD)
300.0
Keywords
GB 29539-2025, GB/T 29539-2025, GBT 29539-2025, GB29539-2025, GB 29539, GB29539, GB/T29539-2025, GB/T 29539, GB/T29539, GBT29539-2025, GBT 29539, GBT29539
Introduction of GB 29539-2025
GB 29539-2025 Minimum allowable values of energy efficiency and energy efficiency grades for household and similar range hoods and ventilating fans 1 Scope This document specifies the grades of energy efficiency. minimum allowable values, test methods and standard implementation for the household and similar range hoods, electric ventilating fans, and multifunctional appliances with ventilating function. This document is applicable to: a) Air-extraction range hoods installed on the upper part of household cooking stoves, stoves or similar appliances, with a rated voltage not more than 250 V; b) Ventilating fans driven by electric motors, with single-phase rated voltage not more than 250 V, rated ventilating input power not more than 500 W, impeller diameter not more than 500 mm, as well as multifunctional appliances with ventilating function. This document is not applicable to: a) Cooking fume suction and extraction device of a downdraft system; b) Commercial range hoods, and other commercial cooking fume extractors; c) Ventilating fans designed exclusively for industrial purposes; d) Ventilating fans intended for use under special conditions, such as where corrosive, flammable and explosive gases, dust, steam or gas are present; e) Ventilating fans for refrigeration equipment or air conditioners and air-to-air energy recovery devices; f) Ventilating fans embedded in appliances (such as stoves and microwave cooking appliances); g) Marine ventilating fans; h) Type C ventilating fans, two-way outlet ventilating fans, and Types B and D ventilating fans with a maximum static pressure of less than 25 Pa; i) Ventilating fans with filter screens and a fresh air PM2.5 filtration efficiency greater than 90% tested according to GB/T 34012-2017. Note: The definitions of types A, B, C, D ventilating fans and the like are quoted from GB/T 14806-2017. 2 Normative References The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 14806-2017 A.C. electric ventilating fans and regulators for household and similar purposes GB/T 17713-2022 Range hoods, and other cooking fume extractors GB/T 22769-2023 Electric bathroom heater (Yuba) GB/T 34012-2017 Air cleaner for ventilation system GB/T 35758-2017 Household electrical appliances - Measurement of standby power 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 14806-2017, GB/T 17713-2022, GB/T 22769-2023 and GB/T 35758-2017, as well as the following apply. 3.1 minimum allowable values of energy efficiency for range hoods minimum allowable values of energy efficiency for range hoods under the specified test conditions 3.2 minimum allowable values of energy efficiency for ventilating fans minimum allowable values of energy efficiency for ventilating fans under the test conditions specified in the standard 3.3 standby mode continuous mode for any product, in which a range hood or ventilating fan provides one or more of the following user-oriented functions or protection functions when connected to the main power: —— other modes (including main function on or off) may be triggered by triggering remote switches (including non-contract mode for the appliance), internal sensors and timers; —— continuous function: information or status display including clock; —— continuous function: sensor-based function. [Source: GB/T 35758-2017, 3.6, modified]
Contents of GB 29539-2025
Contents Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Technical requirements 5 Test method 6 Implementation of the standard Annex A (Normative) Total pressure efficiency at working airflow Annex B (Normative) Standby/off power test method Annex C (Normative) Test method for heating energy consumption of bathroom heater Annex D (Normative) Test method for energy efficiency of ventilating fans
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 29539-2025, GB/T 29539-2025, GBT 29539-2025, GB29539-2025, GB 29539, GB29539, GB/T29539-2025, GB/T 29539, GB/T29539, GBT29539-2025, GBT 29539, GBT29539