2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 30253-2024
GB 30253-2024   Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors (English Version)
Standard No.: GB 30253-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 24500 words Translation Price(USD):735.0 remind me the price change

Email:

Implemented on:2025-10-1 Delivery: via email in 1 business day

→ → →

,,2025-10-1,3C0868C0DAF84C4D1728449530272
Standard No.: GB 30253-2024
English Name: Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors
Chinese Name: 永磁同步电动机能效限定值及能效等级
Chinese Classification: F01    Technical management
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2024-9-29
Implemented on: 2025-10-1
Status: valid
Superseding:GB 30253-2013 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Permanent Magnet Synchronous Motors
Target Language: English
File Format: PDF
Word Count: 24500 words
Translation Price(USD): 735.0
Delivery: via email in 1 business day
GB 30253-2024 Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors 1 Scope This document specifies the energy efficiency grades, technical requirements and test methods for permanent magnet synchronous motors. This document is applicable to permanent magnet synchronous motors for general purpose or explosion-proof purposes in continuous working system, and the scope is as follows: a) an asynchronous-start three-phase permanent-magnet synchronous motor powered by 50 Hz three-phase AC power supply, with a voltage grade of 1140 V and below, a rated power of 0.55 kW ~ 1000 kW and poles of 2~16; b) an asynchronous-start three-phase permanent-magnet synchronous motor with 50 Hz three-phase AC power supply, voltages of 3 kV (3.3 kV), 6 kV and 10 kV, cooling methods of IC81W, IC86W, IC71W (IC3W7), IC411, IC416, IC511, IC611, IC616, IC516 and IC666, rated power of 200 kW to 2000 kW and poles of 4~12; c) a permanent-magnet synchronous motor driven by variable frequency equipment powered by a variable frequency power supply, with a voltage of 1,140 V or below, a rated power of 0.55 kW to 1,250 kW and a rated rotation speed of 45 r/min to 6,000 r/min; d) a permanent-magnet synchronous motor driven by variable frequency equipment powered by a variable frequency power supply, with voltages of 3 kV (3.3 kV), 6 kV and 10 kV, cooling methods of IC81W, IC86W, IC71W (IC3W7), IC411, IC416, IC511, IC611, IC616, IC516 and IC666, rated power of 200 kW or higher and rated rotation speed of 45 r/min to 3000 r/min; e) a permanent magnet synchronous motors for elevator powered by a variable frequency power supply, with voltage of 1140V or below and rated power of 0.55 kW to 110 kW. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 755 Rotating electrical machines - Rating and performance GB/T 22669-2008 Test procedures for three-phase permanent magnet synchronous machines GB/T 32877-2022 Specific test methods for determining losses and efficiency of converter-fed AC motors 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 asynchronous-start three-phase permanent-magnet synchronous motor permanent-magnet synchronous motors started at a certain frequency and voltage by the asynchronous torque generated by the starting winding 3.2 permanent-magnet synchronous motor driven by variable frequency equipment permanent-magnet synchronous motors driven by variable frequency equipment 3.3 minimum allowable values of energy efficiency for permanent magnet synchronous motors minimum allowable values of energy efficiency for permanent magnet synchronous motors under the test conditions specified in the standard 4 Energy efficiency grades The energy efficiency grades for permanent magnet synchronous motors are classified into three grades, among which Grade 1 is the highest. The measured efficiency for permanent magnet synchronous motors of each grade under specified test method shall not be less than those specified in Tables 1~29 . The measured efficiency allowance for permanent magnet synchronous motors of each grade under specified test method shall comply with GB/T 755. For motors of which the rated power values and rotation speed are not listed in the tables, their efficiencies are determined by linear interpolation provided that they are under specified scope. 5 Technical requirements The minimum allowable values of energy efficiency for permanent magnet synchronous
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Energy efficiency grades 5 Technical requirements 6 Test methods
Referred in GB 30253-2024:
*GB/T 755-2019 Rotating electrical machines—Rating and performance
*GB/T 22669-2008 Test procedures for three-phase permanent magnet synchronous machines
*GB/T 32877-2022 Specific test methods for determining losses and efficiency of converter-fed AC motors
Code of China
Standard
GB 30253-2024  Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors (English Version)
Standard No.GB 30253-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count24500 words
Price(USD)735.0
Implemented on2025-10-1
Deliveryvia email in 1 business day
Detail of GB 30253-2024
Standard No.
GB 30253-2024
English Name
Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors
Chinese Name
永磁同步电动机能效限定值及能效等级
Chinese Classification
F01
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2024-9-29
Implemented on
2025-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 30253-2013 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Permanent Magnet Synchronous Motors
Language
English
File Format
PDF
Word Count
24500 words
Price(USD)
735.0
Keywords
GB 30253-2024, GB/T 30253-2024, GBT 30253-2024, GB30253-2024, GB 30253, GB30253, GB/T30253-2024, GB/T 30253, GB/T30253, GBT30253-2024, GBT 30253, GBT30253
Introduction of GB 30253-2024
GB 30253-2024 Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors 1 Scope This document specifies the energy efficiency grades, technical requirements and test methods for permanent magnet synchronous motors. This document is applicable to permanent magnet synchronous motors for general purpose or explosion-proof purposes in continuous working system, and the scope is as follows: a) an asynchronous-start three-phase permanent-magnet synchronous motor powered by 50 Hz three-phase AC power supply, with a voltage grade of 1140 V and below, a rated power of 0.55 kW ~ 1000 kW and poles of 2~16; b) an asynchronous-start three-phase permanent-magnet synchronous motor with 50 Hz three-phase AC power supply, voltages of 3 kV (3.3 kV), 6 kV and 10 kV, cooling methods of IC81W, IC86W, IC71W (IC3W7), IC411, IC416, IC511, IC611, IC616, IC516 and IC666, rated power of 200 kW to 2000 kW and poles of 4~12; c) a permanent-magnet synchronous motor driven by variable frequency equipment powered by a variable frequency power supply, with a voltage of 1,140 V or below, a rated power of 0.55 kW to 1,250 kW and a rated rotation speed of 45 r/min to 6,000 r/min; d) a permanent-magnet synchronous motor driven by variable frequency equipment powered by a variable frequency power supply, with voltages of 3 kV (3.3 kV), 6 kV and 10 kV, cooling methods of IC81W, IC86W, IC71W (IC3W7), IC411, IC416, IC511, IC611, IC616, IC516 and IC666, rated power of 200 kW or higher and rated rotation speed of 45 r/min to 3000 r/min; e) a permanent magnet synchronous motors for elevator powered by a variable frequency power supply, with voltage of 1140V or below and rated power of 0.55 kW to 110 kW. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 755 Rotating electrical machines - Rating and performance GB/T 22669-2008 Test procedures for three-phase permanent magnet synchronous machines GB/T 32877-2022 Specific test methods for determining losses and efficiency of converter-fed AC motors 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 asynchronous-start three-phase permanent-magnet synchronous motor permanent-magnet synchronous motors started at a certain frequency and voltage by the asynchronous torque generated by the starting winding 3.2 permanent-magnet synchronous motor driven by variable frequency equipment permanent-magnet synchronous motors driven by variable frequency equipment 3.3 minimum allowable values of energy efficiency for permanent magnet synchronous motors minimum allowable values of energy efficiency for permanent magnet synchronous motors under the test conditions specified in the standard 4 Energy efficiency grades The energy efficiency grades for permanent magnet synchronous motors are classified into three grades, among which Grade 1 is the highest. The measured efficiency for permanent magnet synchronous motors of each grade under specified test method shall not be less than those specified in Tables 1~29 . The measured efficiency allowance for permanent magnet synchronous motors of each grade under specified test method shall comply with GB/T 755. For motors of which the rated power values and rotation speed are not listed in the tables, their efficiencies are determined by linear interpolation provided that they are under specified scope. 5 Technical requirements The minimum allowable values of energy efficiency for permanent magnet synchronous
Contents of GB 30253-2024
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Energy efficiency grades 5 Technical requirements 6 Test methods
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 30253-2024, GB/T 30253-2024, GBT 30253-2024, GB30253-2024, GB 30253, GB30253, GB/T30253-2024, GB/T 30253, GB/T30253, GBT30253-2024, GBT 30253, GBT30253