2026-4-11 10.8.226.215
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 3095-2026
GB 3095-2026   Ambient air quality standards (English Version)
Standard No.: GB 3095-2026 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):165.0 remind me the price change

Email:

Implemented on:2026-3-1 Delivery: via email in 1~3 business day

→ → →

,,2026-3-1,1F2AFE0D91E212A41772095961544
Standard No.: GB 3095-2026
English Name: Ambient air quality standards
Chinese Name: 环境空气质量标准
Chinese Classification: Z50    Environmental Quality Standard for atmosphere, water and soil
Professional Classification: GB    National Standard
ICS Classification: 13.040.20 13.040.20    Ambient atmospheres 13.040.20
Source Content Issued by: MEE; SAMR
Issued on: 2026-02-27
Implemented on: 2026-3-1
Status: valid
Superseding:GB 3095-2012 Ambient air quality standard
GB 3095-2012/XG1-2018 Ambient air quality standard||includes Amendment 1
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 165.0
Delivery: via email in 1~3 business day
GB 3095-2026 Ambient air quality standards English, Anglais, Englisch, Inglés, えいご ICS 13. 040. 20 CCS Z 50 National Standard of the People’s Republic of China GB 3095-2026 Replaces GB 3095-2012 Ambient air quality standards 环境空气质量标准 (English translation) Issue date: 2026-02-13 Implementation date: 2026-03-01 Issued by the Ministry of Ecology and Environment of the People's Republic of China the State Administration for Market Regulation of the People's Republic of China Contents Foreword II 1 Scope of application 1 2 Normative references 1 3 Terms and definitions 2 4 Classification and quality requirements of ambient air functional zones 3 5 Monitoring 4 6 Validity requirements for data statistics 6 7 Implementation and supervision 6 Annex A (Informative) Reference concentration limits for cadmium, mercury, arsenic, hexavalent chromium, and fluoride in ambient air 7 Ambient air quality standards 1 Scope of application This standard specifies the classification of ambient air functional zones, standard grading, pollutant items, average time and concentration limits, monitoring methods, validity requirements for data statistics, as well as implementation and supervision. This standard applies to the assessment and management of ambient air quality. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. For other documents that are abolished, revised or revised by new documents, the new ones shall apply to this standard. GB/T 9801 Air quality - Determination of carbon monoxide - Non-dispersive infrared spectrometry HJ 193 Technical Specifications for Installation and Acceptance of Ambient air Quality Continuous Automated Monitoring System for SO₂, NO₂, O₃, CO HJ/T 194 Technical specifications on manual methods for ambient air quality monitoring HJ 479 Ambient air - Determination of nitrogen oxides-N-(1-Naphthyl) ethylene diamine dihydrochloride spectrophotometric method HJ 482 Ambient air - Determination of sulfur dioxide - Formaldehyde absorbing-pararosaniline spectrophotometry HJ 504 Ambient air - Determination of ozone - Indigo disulphonate spectrophotometry HJ 539 Ambient air - Determination of lead - Graphite furnace atomic absorption spectrometry HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method HJ 618 Determination of atmospheric articles PM10 and PM2.5 in ambient air by gravimetric method HJ/T 630 Technical guideline on environmental monitoring quality management HJ 646 Ambient air and stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons with gas chromatography/mass spectrometry HJ 647 Ambient air and stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - High performance liquid chromatography HJ653 Specifications and test procedures for ambient air quality continuous automated monitoring system for PM10 and PM2.5 HJ 654 Specifications and Test Procedures for Ambient Air Quality Continuous Automated Monitoring System for SO2, NO2, O3 and CO HJ 655 Technical Specifications for Installation and Acceptance of Ambient Air Quality Continuous Automated Monitoring System for PM10 and PM2.5 HJ 657 Ambient air and stationary source emission - Determination of metals in ambient particulate matter – Inductively coupled plasma/mass spectrometry (ICP-MS) HJ 664 Technical regulation for selection of ambient air quality monitoring stations (on trial) HJ 777 Ambient air and waste gas from stationary sources emission - Determination of metal elements in ambient particle matter-Inductively coupled plasma optical emission spectrometry HJ 817 Technical specifications for operation and quality control of ambient air qualityautomated monitoring system for particulate matter (PM10 and PM2.5) HJ 818 Technical specifications for operation and quality control of ambient air quality continuous automated monitoring system for SO₂, NO₂, O₃, CO HJ 829 Ambient air -Determination of inorganic elements in ambient particle matter - Energy dispersive X-ray fluorescence spectroscopy (ED-XRF) method HJ 830 Ambient air - Determination of inorganic elements in ambient particle matter - Wavelength dispersive X-ray fluorescence spectroscopy (WD-XRF) method HJ 956 Air quality - Determination of benz[a]pyrene in ambient air - High performance liquid chromatography HJ 965 Ambient air - Automatic determination of carbon monoxide - Non-dispersive infrared spectrometry method HJ 1043 Ambient air - Automatic determination of nitrogen oxides - Chemiluminescence method HJ 1044 Ambient air - Automatic determination of sulfur dioxide - Ultraviolet fluorescence method HJ 1225 Ambient air - Automatic determination of ozone - Chemiluminescence method HJ 1263 Ambient air - Determination of total suspended particle - Gravimetric method 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply: 3.1 ambient air outdoor air to which people, plants, animals, and buildings are exposed 3.2 total suspended particle (TSP) particulate matter having an aerodynamic equivalent diameter of 100μm or less in ambient air 3.3 particulate matter (PM10) particulate matter with an aerodynamic equivalent diameter of 10 μm or less in ambient air, also referred to as inhalable particulate matter 3.4 particulate matter (PM2.5) particulate matter with the aerodynamic equivalent diameter of 2.5μm or less in ambient air, also referred to as fine particulate matter 3.5 lead lead and its compounds present in total suspended particles 3.6 benzo[a]pyrene (BaP) benzo[a]pyrene present in particulate matter (particle size of 10 μm or less) 3.7 1-hour average arithmetic mean of pollutant concentrations in any 1 hour 3.8 8-hour average arithmetic mean of average concentrations over 8 consecutive hours, also referred to as 8-hour moving average 3.9 maximum daily 8-hour average maximum value of the 8-hour moving average within a natural day 3.10 daily average arithmetic mean of average concentrations over 24 hours within a natural day, also referred to as 24-hour moving average 3.11 monthly average arithmetic mean of daily average concentrations within a calendar month 3.12 quarterly average arithmetic mean of daily average concentrations within a calendar quarter 3.13 annual mean arithmetic mean of daily average concentrations within a calendar year 3.14 reference state state where the atmospheric temperature is 298.15 K and the atmospheric pressure is 1013.25 kPa 3.15 reference method national ecological environment standard method used as the basis for equivalence assessment of ambient air pollutant monitoring method 3.16 equivalent method ecological environment monitoring method confirmed to be equivalent to the reference method specified in this standard through equivalence assessment organized by the competent department of ecological environment under the State Council 4 Classification and quality requirements of ambient air functional zones 4.1 Classification of ambient air functional zones Ambient air functional zones can be classified into two types: Zone I includes national parks, nature reserves, natural parks, and other areas requiring special protection. Zone II includes residential areas, mixed commercial and residential areas, cultural zones, industrial zones, and rural areas. 4.2 Quality requirements of ambient air functional zones Grade I concentration limits apply to Zone I, and Grade II concentration limits apply to Zone II. For the quality requirements for Zone I and Zone II ambient air functional zones, see Table 1 and Table 2.
Contents Foreword II 1 Scope of application 2 Normative references 3 Terms and definitions 4 Classification and quality requirements of ambient air functional zones 5 Monitoring 6 Validity requirements for data statistics 7 Implementation and supervision Annex A (Informative) Reference concentration limits for cadmium, mercury, arsenic, hexavalent chromium, and fluoride in ambient air
Code of China
Standard
GB 3095-2026  Ambient air quality standards (English Version)
Standard No.GB 3095-2026
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2026-3-1
Deliveryvia email in 1~3 business day
Detail of GB 3095-2026
Standard No.
GB 3095-2026
English Name
Ambient air quality standards
Chinese Name
环境空气质量标准
Chinese Classification
Z50
Professional Classification
GB
ICS Classification
Issued by
MEE; SAMR
Issued on
2026-02-27
Implemented on
2026-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 3095-2012 Ambient air quality standard
GB 3095-2012/XG1-2018 Ambient air quality standard||includes Amendment 1
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
GB 3095-2026, GB/T 3095-2026, GBT 3095-2026, GB3095-2026, GB 3095, GB3095, GB/T3095-2026, GB/T 3095, GB/T3095, GBT3095-2026, GBT 3095, GBT3095
Introduction of GB 3095-2026
GB 3095-2026 Ambient air quality standards English, Anglais, Englisch, Inglés, えいご ICS 13. 040. 20 CCS Z 50 National Standard of the People’s Republic of China GB 3095-2026 Replaces GB 3095-2012 Ambient air quality standards 环境空气质量标准 (English translation) Issue date: 2026-02-13 Implementation date: 2026-03-01 Issued by the Ministry of Ecology and Environment of the People's Republic of China the State Administration for Market Regulation of the People's Republic of China Contents Foreword II 1 Scope of application 1 2 Normative references 1 3 Terms and definitions 2 4 Classification and quality requirements of ambient air functional zones 3 5 Monitoring 4 6 Validity requirements for data statistics 6 7 Implementation and supervision 6 Annex A (Informative) Reference concentration limits for cadmium, mercury, arsenic, hexavalent chromium, and fluoride in ambient air 7 Ambient air quality standards 1 Scope of application This standard specifies the classification of ambient air functional zones, standard grading, pollutant items, average time and concentration limits, monitoring methods, validity requirements for data statistics, as well as implementation and supervision. This standard applies to the assessment and management of ambient air quality. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. For other documents that are abolished, revised or revised by new documents, the new ones shall apply to this standard. GB/T 9801 Air quality - Determination of carbon monoxide - Non-dispersive infrared spectrometry HJ 193 Technical Specifications for Installation and Acceptance of Ambient air Quality Continuous Automated Monitoring System for SO₂, NO₂, O₃, CO HJ/T 194 Technical specifications on manual methods for ambient air quality monitoring HJ 479 Ambient air - Determination of nitrogen oxides-N-(1-Naphthyl) ethylene diamine dihydrochloride spectrophotometric method HJ 482 Ambient air - Determination of sulfur dioxide - Formaldehyde absorbing-pararosaniline spectrophotometry HJ 504 Ambient air - Determination of ozone - Indigo disulphonate spectrophotometry HJ 539 Ambient air - Determination of lead - Graphite furnace atomic absorption spectrometry HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method HJ 618 Determination of atmospheric articles PM10 and PM2.5 in ambient air by gravimetric method HJ/T 630 Technical guideline on environmental monitoring quality management HJ 646 Ambient air and stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons with gas chromatography/mass spectrometry HJ 647 Ambient air and stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - High performance liquid chromatography HJ653 Specifications and test procedures for ambient air quality continuous automated monitoring system for PM10 and PM2.5 HJ 654 Specifications and Test Procedures for Ambient Air Quality Continuous Automated Monitoring System for SO2, NO2, O3 and CO HJ 655 Technical Specifications for Installation and Acceptance of Ambient Air Quality Continuous Automated Monitoring System for PM10 and PM2.5 HJ 657 Ambient air and stationary source emission - Determination of metals in ambient particulate matter – Inductively coupled plasma/mass spectrometry (ICP-MS) HJ 664 Technical regulation for selection of ambient air quality monitoring stations (on trial) HJ 777 Ambient air and waste gas from stationary sources emission - Determination of metal elements in ambient particle matter-Inductively coupled plasma optical emission spectrometry HJ 817 Technical specifications for operation and quality control of ambient air qualityautomated monitoring system for particulate matter (PM10 and PM2.5) HJ 818 Technical specifications for operation and quality control of ambient air quality continuous automated monitoring system for SO₂, NO₂, O₃, CO HJ 829 Ambient air -Determination of inorganic elements in ambient particle matter - Energy dispersive X-ray fluorescence spectroscopy (ED-XRF) method HJ 830 Ambient air - Determination of inorganic elements in ambient particle matter - Wavelength dispersive X-ray fluorescence spectroscopy (WD-XRF) method HJ 956 Air quality - Determination of benz[a]pyrene in ambient air - High performance liquid chromatography HJ 965 Ambient air - Automatic determination of carbon monoxide - Non-dispersive infrared spectrometry method HJ 1043 Ambient air - Automatic determination of nitrogen oxides - Chemiluminescence method HJ 1044 Ambient air - Automatic determination of sulfur dioxide - Ultraviolet fluorescence method HJ 1225 Ambient air - Automatic determination of ozone - Chemiluminescence method HJ 1263 Ambient air - Determination of total suspended particle - Gravimetric method 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply: 3.1 ambient air outdoor air to which people, plants, animals, and buildings are exposed 3.2 total suspended particle (TSP) particulate matter having an aerodynamic equivalent diameter of 100μm or less in ambient air 3.3 particulate matter (PM10) particulate matter with an aerodynamic equivalent diameter of 10 μm or less in ambient air, also referred to as inhalable particulate matter 3.4 particulate matter (PM2.5) particulate matter with the aerodynamic equivalent diameter of 2.5μm or less in ambient air, also referred to as fine particulate matter 3.5 lead lead and its compounds present in total suspended particles 3.6 benzo[a]pyrene (BaP) benzo[a]pyrene present in particulate matter (particle size of 10 μm or less) 3.7 1-hour average arithmetic mean of pollutant concentrations in any 1 hour 3.8 8-hour average arithmetic mean of average concentrations over 8 consecutive hours, also referred to as 8-hour moving average 3.9 maximum daily 8-hour average maximum value of the 8-hour moving average within a natural day 3.10 daily average arithmetic mean of average concentrations over 24 hours within a natural day, also referred to as 24-hour moving average 3.11 monthly average arithmetic mean of daily average concentrations within a calendar month 3.12 quarterly average arithmetic mean of daily average concentrations within a calendar quarter 3.13 annual mean arithmetic mean of daily average concentrations within a calendar year 3.14 reference state state where the atmospheric temperature is 298.15 K and the atmospheric pressure is 1013.25 kPa 3.15 reference method national ecological environment standard method used as the basis for equivalence assessment of ambient air pollutant monitoring method 3.16 equivalent method ecological environment monitoring method confirmed to be equivalent to the reference method specified in this standard through equivalence assessment organized by the competent department of ecological environment under the State Council 4 Classification and quality requirements of ambient air functional zones 4.1 Classification of ambient air functional zones Ambient air functional zones can be classified into two types: Zone I includes national parks, nature reserves, natural parks, and other areas requiring special protection. Zone II includes residential areas, mixed commercial and residential areas, cultural zones, industrial zones, and rural areas. 4.2 Quality requirements of ambient air functional zones Grade I concentration limits apply to Zone I, and Grade II concentration limits apply to Zone II. For the quality requirements for Zone I and Zone II ambient air functional zones, see Table 1 and Table 2.
Contents of GB 3095-2026
Contents Foreword II 1 Scope of application 2 Normative references 3 Terms and definitions 4 Classification and quality requirements of ambient air functional zones 5 Monitoring 6 Validity requirements for data statistics 7 Implementation and supervision Annex A (Informative) Reference concentration limits for cadmium, mercury, arsenic, hexavalent chromium, and fluoride in ambient air
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 3095-2026, GB/T 3095-2026, GBT 3095-2026, GB3095-2026, GB 3095, GB3095, GB/T3095-2026, GB/T 3095, GB/T3095, GBT3095-2026, GBT 3095, GBT3095