2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50050-2007
GB 50050-2007   Code for Design of Industrial Recirculating Cooling Water Treatmen (English Version)
Standard No.: GB 50050-2007 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 36500 words Translation Price(USD):130.0 remind me the price change

Email:

Implemented on:2008-5-1 Delivery: via email in 1~5 business day

→ → →

,2018-1-1,2008-5-1,1411381818363744A0284FD4599C5
Standard No.: GB 50050-2007
English Name: Code for Design of Industrial Recirculating Cooling Water Treatmen
Chinese Name: 工业循环冷却水处理设计规范
Chinese Classification: P40    Water supply and draining engineering in general
Professional Classification: GB    National Standard
ICS Classification: 91.140.60 91.140.60    Water supply systems 91.140.60
Source Content Issued by: Ministry of Construction
Issued on: 2008-03-01
Implemented on: 2008-5-1
Status: superseded
Superseded by:GB/T 50050-2017 Code for design of industrial recirculating cooling water treatment
Superseded on:2018-1-1
Superseding:GB 50050-1995 Code for design of industrial recirculating cooling water treatment
Target Language: English
File Format: PDF
Word Count: 36500 words
Translation Price(USD): 130.0
Delivery: via email in 1~5 business day
1. General Provisions 1.0.1 The code is formulated to implement national water resources saving and environment protection policies, promote the cyclic utilization of industrial cooling water and the sewage reclamations, effectively control and reduce all sorts of harms caused by re-circulated cooling water, guarantee the recuperation efficiency and service life of implements, decrease the water pollution and enable the industrial cycle cooling water treatment to be state-of-art, economical and practical, and secure, stable. 1.0.2 This code is applicable to newly-built, expanded and re-built re-circulated cooling water treatment designs which adopt surface water, groundwater and reuse water as make-up water. 1.0.3 Industrial cooling water treatment design should correspond with demands such as production safety, environment protection, energy conservation and water saving, and is facilitated to carry out construction, maintenance and operation management. 1.0.4 Industrial cycle cooling water treatment design should introduce state-of-art productive practice experience and scientific payoffs and adopt new technique positively and prudently. 1.0.5 Industrial cycle cooling water treatment designs should correspond with relative national current standards and specifications, besides this code. 2. Terms and Symbols 2.1 Terms 2.1.1 Recirculating Cooling Water System A water-feed system that water circulates as cooling medium, and consist of heat-exchange implement, cooling implement, processing facility, water pump, pipe and other relative facilities. 2.1.2 Indirect Open Recirculating Cooling Water System A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled, and recirculating cooling water contacts with the atmosphere directly. 2.1.3 Indirect Closed Recirculating Cooling Water System A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled indirectly as well as between circulating cooling water and cooling medium. 2.1.4 Totally Closed System An indirect closed recirculating cooling water system that its circulating cooling water doesn't contact with the atmosphere. 2.1.5 Semi Closed System An indirect closed recirculating cooling water system that it’s circulating cooling water contacts with the atmosphere partially. 2.1.6 Direct Open Recirculating Cooling Water System (Direct Open Recirculating Cooling) A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled, and recirculating cooling water contacts with the atmosphere directly. 2.1.7 Open System A general term for indirect cooling open system and direct cooling system. 2.1.8 Chemicals
1 General Provision 2 Terms and Symbols 3 Circulating Cooling Water Treatment 4 Side-stream Water Treatment 5 Make-up Water Treatments 6 Reclaimed Water Treatments 7 Effluent Treatments 8 Chemicals Storage and Dosing 9 Monitoring, Controlling and Detecting Annex A Water Analysis Items Annex B Water Quality Analysis Data Checking Annex C Circulating Cooling Water pH- Mr Change Curve Diagram
GB 50050-2007 is referred in:
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* SY/T 0011-2007 Code for design of natural gas conditioning plant
* GB 50620-2010 Code for design of viscose fibre plant
* GB 50049-2011 Code for design of small fossil fired power plant
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* GB 50049-2011 Code for design of small fossil fired power plant
* GB 50620-2010 Code for design of viscose fibre plant
* GB 50049-2011 Code for design of small fossil fired power plant
* DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
* DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
* DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
* DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
* DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
* SY/T 0011-2007 Code for design of natural gas conditioning plant
* DL/T 5165-2002 Design Code for Heating Ventilation and Air Conditioning of Power House of Hydropower Station
* GB 50029-2014 Code for Design of Compressed Air Station
* GB 50030-2013 Oxygen Station Design Specifications
* HJ 2019-2012 Technical specification for waste water treatment and reuse of iron and steel industry
* GB 50157-2013 Code for Design of Metro
* GB 50251-2015 Design code for gas transmission pipeline engineering
*GB/T 10870-2014/XG1-2015 The methods of performance test for water chilling(heat pump) packages using the vaper compression cycle (including Amendment 1)
*GB/T 19923-2005 The reuse of urban recycling water--Water quality standard for industrial uses
*GB/T 23248-2009 Code for design of seawater treatment for recirculating cooling seawater system
*DL/T 5339-2006 Code for hydraulic design of fossil fuel power plants
*GB/T 50746-2012 Code for design of petrochemical recirculation cooling water unit
*GB 50721-2011 Code for Design of Water Supply & Drainage of Iron and Steel Enterprises
Code of China
Standard
GB 50050-2007  Code for Design of Industrial Recirculating Cooling Water Treatmen (English Version)
Standard No.GB 50050-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count36500 words
Price(USD)130.0
Implemented on2008-5-1
Deliveryvia email in 1~5 business day
Detail of GB 50050-2007
Standard No.
GB 50050-2007
English Name
Code for Design of Industrial Recirculating Cooling Water Treatmen
Chinese Name
工业循环冷却水处理设计规范
Chinese Classification
P40
Professional Classification
GB
ICS Classification
Issued by
Ministry of Construction
Issued on
2008-03-01
Implemented on
2008-5-1
Status
superseded
Superseded by
GB/T 50050-2017 Code for design of industrial recirculating cooling water treatment
Superseded on
2018-1-1
Abolished on
Superseding
GB 50050-1995 Code for design of industrial recirculating cooling water treatment
Language
English
File Format
PDF
Word Count
36500 words
Price(USD)
130.0
Keywords
GB 50050-2007, GB/T 50050-2007, GBT 50050-2007, GB50050-2007, GB 50050, GB50050, GB/T50050-2007, GB/T 50050, GB/T50050, GBT50050-2007, GBT 50050, GBT50050
Introduction of GB 50050-2007
1. General Provisions 1.0.1 The code is formulated to implement national water resources saving and environment protection policies, promote the cyclic utilization of industrial cooling water and the sewage reclamations, effectively control and reduce all sorts of harms caused by re-circulated cooling water, guarantee the recuperation efficiency and service life of implements, decrease the water pollution and enable the industrial cycle cooling water treatment to be state-of-art, economical and practical, and secure, stable. 1.0.2 This code is applicable to newly-built, expanded and re-built re-circulated cooling water treatment designs which adopt surface water, groundwater and reuse water as make-up water. 1.0.3 Industrial cooling water treatment design should correspond with demands such as production safety, environment protection, energy conservation and water saving, and is facilitated to carry out construction, maintenance and operation management. 1.0.4 Industrial cycle cooling water treatment design should introduce state-of-art productive practice experience and scientific payoffs and adopt new technique positively and prudently. 1.0.5 Industrial cycle cooling water treatment designs should correspond with relative national current standards and specifications, besides this code. 2. Terms and Symbols 2.1 Terms 2.1.1 Recirculating Cooling Water System A water-feed system that water circulates as cooling medium, and consist of heat-exchange implement, cooling implement, processing facility, water pump, pipe and other relative facilities. 2.1.2 Indirect Open Recirculating Cooling Water System A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled, and recirculating cooling water contacts with the atmosphere directly. 2.1.3 Indirect Closed Recirculating Cooling Water System A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled indirectly as well as between circulating cooling water and cooling medium. 2.1.4 Totally Closed System An indirect closed recirculating cooling water system that its circulating cooling water doesn't contact with the atmosphere. 2.1.5 Semi Closed System An indirect closed recirculating cooling water system that it’s circulating cooling water contacts with the atmosphere partially. 2.1.6 Direct Open Recirculating Cooling Water System (Direct Open Recirculating Cooling) A circulating cooling water system that the heat is transferred between circulating cooling water and cooling medium cooled, and recirculating cooling water contacts with the atmosphere directly. 2.1.7 Open System A general term for indirect cooling open system and direct cooling system. 2.1.8 Chemicals
Contents of GB 50050-2007
1 General Provision 2 Terms and Symbols 3 Circulating Cooling Water Treatment 4 Side-stream Water Treatment 5 Make-up Water Treatments 6 Reclaimed Water Treatments 7 Effluent Treatments 8 Chemicals Storage and Dosing 9 Monitoring, Controlling and Detecting Annex A Water Analysis Items Annex B Water Quality Analysis Data Checking Annex C Circulating Cooling Water pH- Mr Change Curve Diagram
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50050-2007, GB/T 50050-2007, GBT 50050-2007, GB50050-2007, GB 50050, GB50050, GB/T50050-2007, GB/T 50050, GB/T50050, GBT50050-2007, GBT 50050, GBT50050