2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50681-2011
GB 50681-2011   Code for design of machinery building architecture (English Version)
Standard No.: GB 50681-2011 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 24000 words Translation Price(USD):480.0 remind me the price change

Email:

Implemented on:2012-5-1 Delivery: via email in 1 business day

→ → →

,,2012-5-1,141138181900310355104E40B83C3
Standard No.: GB 50681-2011
English Name: Code for design of machinery building architecture
Chinese Name: 机械工业厂房建筑设计规范
Chinese Classification: P34    Industrial construction engineering
Professional Classification: GB    National Standard
ICS Classification: 91.040.20 91.040.20    Buildings for commerce and industry 91.040.20
Source Content Issued by: MOC
Issued on: 2011-05-12
Implemented on: 2012-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 24000 words
Translation Price(USD): 480.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with view to achieving safety and usability, advanced technology, environmental protection and energy conservation, economy and rationality, convenient construction and maintenance in design of machinery building and its attachment building architecture. 1.0.2 This code is applicable to the following scopes: 1 Design of constructed, extended and renovated machinery building and its attachment building architecture ; 2 Architecture design of ionizing radiation room in machinery factory; 3 Architecture design that shielding layer is added by the use of buildings under 0.15MHz~30MHz shielding frequency of electromagnetic shielding room in the machinery factory. 1.0.3 Design of machinery building and its attachment building architecture shall meet the requirements of this code and the current relevant standards. 2 Terms 2.0.1 United workshop The building composed of multiple process workshops. 2.0.2 Attachment building Auxiliary buildings for office, scientific research, technical, living and sanitary facilities and warehouse that are arranged in adjacent zone for production services of machinery building or independently in the factory area. 2.0.3 Electromagnetic shielding room Mutual induction facilities against static electricity or electromagnetism. 2.0.4 Crane beam slidewalk The plate arranged along one side of the crane beam surface in the building for traveling of workers. 2.0.5 Crane work grade Crane level determined according to loading state and utilization grade. 3 Basic Requirements
Contents 1 General Provisions 2 Terms 3 Basic Requirements 4 Roofing 4.1 Roofing Structure 4.2 Membrane Water-proof Roofing 4.3 Coated Water-proof Roofing 4.4 Rigid Water-proof Roofing 4.5 Thermal Insulation Roofing 4.6 Metal Contour Plate Roofing 4.7 Roofing Drainage 5 Wall 6 Ground and Floor 6.1 Surface Layer 6.2 Cushion 6.3 Footsteps, Ramp, Apron and Ditch 6.4 Floor and Ground Structure 7 Door and Window 7.1 Door 7.2 Side Window 7.3 Skylight 7.4 Wind Screen 8 Stairs, Steel Ladder, Elevator and Crane Beam Slidewalk 8.1 Stairs 8.2 Steel Ladder 8.3 Elevator 8.4 Crane Beam Slidewalk 9 Decoration Engineering 9.1 Exterior Wall Decoration 9.2 Interior Wall Decoration 9.3 Ceiling and Suspended Ceiling 10 Waterproofing of Underground Engineering 11 Anti-corrosion Design 11.1 Building Layout 11.2 Load Bearing and Building Envelope 11.3 Ground and Floor 11.4 Anti-corrosion Coating 12 Ionizing Radiation Room 13 Electromagnetic Shielding Room 13.1 Basic Requirements 13.2 Shielding Efficiency 13.3 Shielding Material and the Structural Form 13.4 Construction of Shielding Layer 14 Noise Control 14.1 Noise Control 14.2 Sound Insulation 14.3 Sound Absorption 14.4 Noise Elimination 15 Air Conditioning Region 15.1 Building Lay-out 15.2 Thermal Performance Design for Building Envelope 15.3 Roofing, Suspended Ceiling and Technical Interlayer 15.4 Wall 15.5 Ground and Floor 15.6 Doors and Windows Appendix A Calculation Parameter for Thermal Performance of Machinery Building and Its Attachment Building Indoor in Winter Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50681-2011:
* GB 50011-2010 Code for seismic design of buildings
* GB 50010-2010 Code for design of concrete structures
Code of China
Standard
GB 50681-2011  Code for design of machinery building architecture (English Version)
Standard No.GB 50681-2011
Statusvalid
LanguageEnglish
File FormatPDF
Word Count24000 words
Price(USD)480.0
Implemented on2012-5-1
Deliveryvia email in 1 business day
Detail of GB 50681-2011
Standard No.
GB 50681-2011
English Name
Code for design of machinery building architecture
Chinese Name
机械工业厂房建筑设计规范
Chinese Classification
P34
Professional Classification
GB
ICS Classification
Issued by
MOC
Issued on
2011-05-12
Implemented on
2012-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
24000 words
Price(USD)
480.0
Keywords
GB 50681-2011, GB/T 50681-2011, GBT 50681-2011, GB50681-2011, GB 50681, GB50681, GB/T50681-2011, GB/T 50681, GB/T50681, GBT50681-2011, GBT 50681, GBT50681
Introduction of GB 50681-2011
1 General Provisions 1.0.1 This code is formulated with view to achieving safety and usability, advanced technology, environmental protection and energy conservation, economy and rationality, convenient construction and maintenance in design of machinery building and its attachment building architecture. 1.0.2 This code is applicable to the following scopes: 1 Design of constructed, extended and renovated machinery building and its attachment building architecture ; 2 Architecture design of ionizing radiation room in machinery factory; 3 Architecture design that shielding layer is added by the use of buildings under 0.15MHz~30MHz shielding frequency of electromagnetic shielding room in the machinery factory. 1.0.3 Design of machinery building and its attachment building architecture shall meet the requirements of this code and the current relevant standards. 2 Terms 2.0.1 United workshop The building composed of multiple process workshops. 2.0.2 Attachment building Auxiliary buildings for office, scientific research, technical, living and sanitary facilities and warehouse that are arranged in adjacent zone for production services of machinery building or independently in the factory area. 2.0.3 Electromagnetic shielding room Mutual induction facilities against static electricity or electromagnetism. 2.0.4 Crane beam slidewalk The plate arranged along one side of the crane beam surface in the building for traveling of workers. 2.0.5 Crane work grade Crane level determined according to loading state and utilization grade. 3 Basic Requirements
Contents of GB 50681-2011
Contents 1 General Provisions 2 Terms 3 Basic Requirements 4 Roofing 4.1 Roofing Structure 4.2 Membrane Water-proof Roofing 4.3 Coated Water-proof Roofing 4.4 Rigid Water-proof Roofing 4.5 Thermal Insulation Roofing 4.6 Metal Contour Plate Roofing 4.7 Roofing Drainage 5 Wall 6 Ground and Floor 6.1 Surface Layer 6.2 Cushion 6.3 Footsteps, Ramp, Apron and Ditch 6.4 Floor and Ground Structure 7 Door and Window 7.1 Door 7.2 Side Window 7.3 Skylight 7.4 Wind Screen 8 Stairs, Steel Ladder, Elevator and Crane Beam Slidewalk 8.1 Stairs 8.2 Steel Ladder 8.3 Elevator 8.4 Crane Beam Slidewalk 9 Decoration Engineering 9.1 Exterior Wall Decoration 9.2 Interior Wall Decoration 9.3 Ceiling and Suspended Ceiling 10 Waterproofing of Underground Engineering 11 Anti-corrosion Design 11.1 Building Layout 11.2 Load Bearing and Building Envelope 11.3 Ground and Floor 11.4 Anti-corrosion Coating 12 Ionizing Radiation Room 13 Electromagnetic Shielding Room 13.1 Basic Requirements 13.2 Shielding Efficiency 13.3 Shielding Material and the Structural Form 13.4 Construction of Shielding Layer 14 Noise Control 14.1 Noise Control 14.2 Sound Insulation 14.3 Sound Absorption 14.4 Noise Elimination 15 Air Conditioning Region 15.1 Building Lay-out 15.2 Thermal Performance Design for Building Envelope 15.3 Roofing, Suspended Ceiling and Technical Interlayer 15.4 Wall 15.5 Ground and Floor 15.6 Doors and Windows Appendix A Calculation Parameter for Thermal Performance of Machinery Building and Its Attachment Building Indoor in Winter Explanation of Wording in This Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50681-2011, GB/T 50681-2011, GBT 50681-2011, GB50681-2011, GB 50681, GB50681, GB/T50681-2011, GB/T 50681, GB/T50681, GBT50681-2011, GBT 50681, GBT50681