2025-12-14 10.2.82.121
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5135.2-2025
GB 5135.2-2025   Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm (English Version)
Standard No.: GB 5135.2-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):360.0 remind me the price change

Email:

Implemented on:2026-11-1 Delivery: via email in 1~5 business day

→ → →

,,2026-11-1,32F5E68371C9370D1762263300859
Standard No.: GB 5135.2-2025
English Name: Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm
Chinese Name: 自动喷水灭火系统 第2部分:湿式报警阀、延迟器、水力警铃
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-10-31
Implemented on: 2026-11-1
Status: to be valid
Superseding:GB 5135.2-2003 Automatic sprinkler system—Part 2:Wet system alarm valves、retard chamber、water motor alarm
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 360.0
Delivery: via email in 1~5 business day
GB 5135.2-2025 Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB 5135.2-2025 Replaces GB 5135.2-2003 Automatic sprinkler system - Part 2: Wet system alarm valves, retard chamber and water motor alarm 自动喷水灭火系统 第2部分:湿式报警阀、延迟器、水力警铃 Issue date: 2025-10-31 Implementation date: 2026-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Designation 5 Requirements 5.1 General Requirements 5.2 Technical Requirements 6 Test Methods 6.1 Sampling and Temperature Treatment 6.2 Freezing Point 6.3 Freeze-Thaw Stability 6.4 Viscosity 6.5 pH Value 6.6 Corrosion Rate 6.7 Surface Tension 6.8 Wetting Ability 6.9 Expansion Ratio and 25% Drainage Time 6.10 Thermal Protection Performance 6.11 Class A Fire Extinguishing Performance 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Appendix A (Normative) Standard Compressed Air Foam System Operation Method 1 Scope This document defines the terms and definitions of wet system alarm valves, retard chambers, and water motor alarms in automatic sprinkler systems. It specifies the classification, model designation, requirements, inspection rules, marking, instruction manuals, packaging, transportation, and storage for wet system alarm valves, retard chambers, and water motor alarms, and describes the corresponding test methods. This document applies to the design, manufacture, and inspection of wet system alarm valves, retard chambers, and water motor alarms in automatic sprinkler systems. 2 Normative References The contents of the following documents, through normative references in this text, constitute essential provisions of this document. For dated references, only the edition cited applies; for undated references, the latest version (including all amendments) applies. GB 5135.11 Automatic sprinkler systems—Part 11: Grooved pipe fittings GB/T 7306 (all parts) 55° sealing pipe threads GB/T 9124.1 Steel pipe flanges—Part 1: PN series GB/T 9124.2 Steel pipe flanges—Part 2: Class series GB/T 9969 General principles for instruction manuals of industrial products GB/T 17241.1 Cast iron pipe flanges—Part 1: PN series GB/T 17241.2 Cast iron pipe flanges—Part 2: Class series 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Wet system alarm valve A one-way valve that allows water to flow into a wet fire protection system and drives the associated alarm components at specified pressure and flow rates. 3.2 Sealing assembly The main movable sealing component in a wet system alarm valve that prevents backflow of water. 3.3 Compensator An auxiliary component that minimizes false actuation of the wet system alarm valve due to water source pressure fluctuations or surges. 3.4 Retard chamber A volumetric device that minimizes false alarms caused by water source pressure fluctuations or surges. 3.5 Water motor alarm A hydraulically driven alarm device that produces audible signals. 3.6 Ready condition The state where the wet system alarm valve is installed in the piping system, supplied with stable water pressure from the water source, and no water flows from any outlet on the system side. 3.7 Rated working pressure The maximum working pressure allowed for the wet system alarm valve, retard chamber, and water motor alarm in the ready condition (3.6) or operating state. 3.8 Service pressure The static water pressure at the inlet of the valve when the wet system alarm valve is in the ready condition (3.6). 3.9 System pressure The static water pressure at the outlet of the valve when the wet system alarm valve is in the ready condition (3.6). 3.10 Retard time The time difference between the wet system alarm valve with and without a retard chamber, from the moment water is released from the system side until the alarm device emits a continuous alarm. 4 Classification and Designation 4.1 Classification by structural form: a) Butterfly-type wet system alarm valve, designated as "D"; b) Flap-type wet system alarm valve, no designation. 4.2 Classification by connection form: a) Grooved connection, designated as "G"; b) Threaded connection, designated as "L"; c) Flanged connection, no designation. 5 Model Designation 5.1 Model designation for wet system alarm valves The model designation for wet system alarm valves shall comply with the following rules: Example: ZSFZD 100-1.2-G indicates a butterfly-type wet system alarm valve with a grooved connection, a rated working pressure of 1.2 MPa, and a nominal diameter of 100 mm. 5.2 Model designation for retard chambers and water motor alarms The model designation for retard chambers and water motor alarms shall comply with the provisions of Appendix A. 6 Requirements 6.1 Appearance and Marking 6.1.1 Appearance Wet system alarm valves, retard chambers, and water motor alarms shall have a smooth surface, no processing defects or impact damage, uniform coating, and complete markings. 6.1.2 Marking Wet system alarm valves shall be clearly marked, and the following information shall be permanently and legibly indicated in a prominent position: a) Product name and model; b) Name or trademark of the manufacturer; c) Rated working pressure; d) Applicable standard; e) Date of manufacture and product serial number; f) Water flow direction for installation. 6.2 Specifications The nominal diameters of the inlet and outlet of wet system alarm valves shall be 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, and 250 mm. 6.3 Rated working pressure
Code of China
Standard
GB 5135.2-2025  Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm (English Version)
Standard No.GB 5135.2-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)360.0
Implemented on2026-11-1
Deliveryvia email in 1~5 business day
Detail of GB 5135.2-2025
Standard No.
GB 5135.2-2025
English Name
Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm
Chinese Name
自动喷水灭火系统 第2部分:湿式报警阀、延迟器、水力警铃
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-10-31
Implemented on
2026-11-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5135.2-2003 Automatic sprinkler system—Part 2:Wet system alarm valves、retard chamber、water motor alarm
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
360.0
Keywords
GB 5135.2-2025, GB/T 5135.2-2025, GBT 5135.2-2025, GB5135.2-2025, GB 5135.2, GB5135.2, GB/T5135.2-2025, GB/T 5135.2, GB/T5135.2, GBT5135.2-2025, GBT 5135.2, GBT5135.2
Introduction of GB 5135.2-2025
GB 5135.2-2025 Automatic sprinkler system—Part 2: Wet system alarm valves; retard chamber and water motor alarm English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 13.220.10 CCS H 57 National Standard of the People's Republic of China ‌GB 5135.2-2025 Replaces GB 5135.2-2003 Automatic sprinkler system - Part 2: Wet system alarm valves, retard chamber and water motor alarm 自动喷水灭火系统 第2部分:湿式报警阀、延迟器、水力警铃 Issue date: 2025-10-31 Implementation date: 2026-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Designation 5 Requirements 5.1 General Requirements 5.2 Technical Requirements 6 Test Methods 6.1 Sampling and Temperature Treatment 6.2 Freezing Point 6.3 Freeze-Thaw Stability 6.4 Viscosity 6.5 pH Value 6.6 Corrosion Rate 6.7 Surface Tension 6.8 Wetting Ability 6.9 Expansion Ratio and 25% Drainage Time 6.10 Thermal Protection Performance 6.11 Class A Fire Extinguishing Performance 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Appendix A (Normative) Standard Compressed Air Foam System Operation Method 1 Scope This document defines the terms and definitions of wet system alarm valves, retard chambers, and water motor alarms in automatic sprinkler systems. It specifies the classification, model designation, requirements, inspection rules, marking, instruction manuals, packaging, transportation, and storage for wet system alarm valves, retard chambers, and water motor alarms, and describes the corresponding test methods. This document applies to the design, manufacture, and inspection of wet system alarm valves, retard chambers, and water motor alarms in automatic sprinkler systems. 2 Normative References The contents of the following documents, through normative references in this text, constitute essential provisions of this document. For dated references, only the edition cited applies; for undated references, the latest version (including all amendments) applies. GB 5135.11 Automatic sprinkler systems—Part 11: Grooved pipe fittings GB/T 7306 (all parts) 55° sealing pipe threads GB/T 9124.1 Steel pipe flanges—Part 1: PN series GB/T 9124.2 Steel pipe flanges—Part 2: Class series GB/T 9969 General principles for instruction manuals of industrial products GB/T 17241.1 Cast iron pipe flanges—Part 1: PN series GB/T 17241.2 Cast iron pipe flanges—Part 2: Class series 3 Terms and Definitions The following terms and definitions apply to this document. 3.1 Wet system alarm valve A one-way valve that allows water to flow into a wet fire protection system and drives the associated alarm components at specified pressure and flow rates. 3.2 Sealing assembly The main movable sealing component in a wet system alarm valve that prevents backflow of water. 3.3 Compensator An auxiliary component that minimizes false actuation of the wet system alarm valve due to water source pressure fluctuations or surges. 3.4 Retard chamber A volumetric device that minimizes false alarms caused by water source pressure fluctuations or surges. 3.5 Water motor alarm A hydraulically driven alarm device that produces audible signals. 3.6 Ready condition The state where the wet system alarm valve is installed in the piping system, supplied with stable water pressure from the water source, and no water flows from any outlet on the system side. 3.7 Rated working pressure The maximum working pressure allowed for the wet system alarm valve, retard chamber, and water motor alarm in the ready condition (3.6) or operating state. 3.8 Service pressure The static water pressure at the inlet of the valve when the wet system alarm valve is in the ready condition (3.6). 3.9 System pressure The static water pressure at the outlet of the valve when the wet system alarm valve is in the ready condition (3.6). 3.10 Retard time The time difference between the wet system alarm valve with and without a retard chamber, from the moment water is released from the system side until the alarm device emits a continuous alarm. 4 Classification and Designation 4.1 Classification by structural form: a) Butterfly-type wet system alarm valve, designated as "D"; b) Flap-type wet system alarm valve, no designation. 4.2 Classification by connection form: a) Grooved connection, designated as "G"; b) Threaded connection, designated as "L"; c) Flanged connection, no designation. 5 Model Designation 5.1 Model designation for wet system alarm valves The model designation for wet system alarm valves shall comply with the following rules: Example: ZSFZD 100-1.2-G indicates a butterfly-type wet system alarm valve with a grooved connection, a rated working pressure of 1.2 MPa, and a nominal diameter of 100 mm. 5.2 Model designation for retard chambers and water motor alarms The model designation for retard chambers and water motor alarms shall comply with the provisions of Appendix A. 6 Requirements 6.1 Appearance and Marking 6.1.1 Appearance Wet system alarm valves, retard chambers, and water motor alarms shall have a smooth surface, no processing defects or impact damage, uniform coating, and complete markings. 6.1.2 Marking Wet system alarm valves shall be clearly marked, and the following information shall be permanently and legibly indicated in a prominent position: a) Product name and model; b) Name or trademark of the manufacturer; c) Rated working pressure; d) Applicable standard; e) Date of manufacture and product serial number; f) Water flow direction for installation. 6.2 Specifications The nominal diameters of the inlet and outlet of wet system alarm valves shall be 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, and 250 mm. 6.3 Rated working pressure
Contents of GB 5135.2-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5135.2-2025, GB/T 5135.2-2025, GBT 5135.2-2025, GB5135.2-2025, GB 5135.2, GB5135.2, GB/T5135.2-2025, GB/T 5135.2, GB/T5135.2, GBT5135.2-2025, GBT 5135.2, GBT5135.2