1 Subject content and applicable scope
This standard describes the determination theory of aluminium in calcium metal, and specifies the analytical procedures, result calculation and method precision.
It is applicable to the determination of aluminum in calcium metal. The determination range is 10~1 000μg/g with allowable amount of impurities (mg/g): 1.5 of Fe, 3.0 of Cu, 1.0 of Mn, 1.0 of Ni, 0.3 of Cr, 0.3 of Co and 10.0 of Mg.
2 Method summary
Dissolve the specimen with hydrochloric acid (1+1), add sodium acetate and copper reagents, adjust the pH value to 5.6~6.0, extract and separate impurities such as iron, nickel, copper and manganese with chloroform, and then add oxine chloroform to extract aluminium, and measure the absorbance of the organic phase at 390nm spectrophotometer wavelength.
3 Instrument
3.1 Spectrophotometer (wavelength of 390nm may be selected).
3.2 Acidometer (pH value error is not more than 0.1).
3.3 Glass electrode.
3.4 Calomel electrode.
1 Subject content and applicable scope
2 Method summary
3 Apparatuses
4 Reagents
5 Plotting of standard curve
6 Procedure
7 Calculation of analytical results
8 Method precision
Standard
GB/T 10267.4-1988 Method for analysis of calcium metal-The determination of aluminium by oxine chloroform extraction photometric method (English Version)
Standard No.
GB/T 10267.4-1988
Status
to be superseded
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
84.0
Implemented on
1989-10-1
Delivery
via email in 1 business day
Detail of GB/T 10267.4-1988
Standard No.
GB/T 10267.4-1988
English Name
Method for analysis of calcium metal-The determination of aluminium by oxine chloroform extraction photometric method
1 Subject content and applicable scope
This standard describes the determination theory of aluminium in calcium metal, and specifies the analytical procedures, result calculation and method precision.
It is applicable to the determination of aluminum in calcium metal. The determination range is 10~1 000μg/g with allowable amount of impurities (mg/g): 1.5 of Fe, 3.0 of Cu, 1.0 of Mn, 1.0 of Ni, 0.3 of Cr, 0.3 of Co and 10.0 of Mg.
2 Method summary
Dissolve the specimen with hydrochloric acid (1+1), add sodium acetate and copper reagents, adjust the pH value to 5.6~6.0, extract and separate impurities such as iron, nickel, copper and manganese with chloroform, and then add oxine chloroform to extract aluminium, and measure the absorbance of the organic phase at 390nm spectrophotometer wavelength.
3 Instrument
3.1 Spectrophotometer (wavelength of 390nm may be selected).
3.2 Acidometer (pH value error is not more than 0.1).
3.3 Glass electrode.
3.4 Calomel electrode.
Contents of GB/T 10267.4-1988
1 Subject content and applicable scope
2 Method summary
3 Apparatuses
4 Reagents
5 Plotting of standard curve
6 Procedure
7 Calculation of analytical results
8 Method precision