2023-3-28 18.206.92.240
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 12519-2010
GB/T 12519-2010   General specification of analytical instruments (English Version)
Standard No.: GB/T 12519-2010 Status:abolished remind me the status change

Email:

Language:English File Format:PDF
Word Count: 7000 words Price(USD):210.0 remind me the price change

Email:

Implemented on:2011-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 12519-2010
English Name: General specification of analytical instruments
Chinese Name: 分析仪器通用技术条件
Chinese Classification: N53    Electrochemical, thermochemistry and optical profile type analyzer
Professional Classification: GB    National Standard
ICS Classification: 71.040.01 71.040.01    Analytical chemistry in general 71.040.01
Issued by: AQSIQ, SAC
Issued on: 2010-12-01
Implemented on: 2011-5-1
Status: abolished
Superseded by:GB/T 12519-2021 General specification of analytical instruments
Superseded on:2022-5-1
Abolished on:2022-05-01
Superseding:GB/T 12519-1990 General specification of analytical instruments
Language: English
File Format: PDF
Word Count: 7000 words
Price(USD): 210.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is a revision of and supersedes "General Specification of Analytical Instruments" (GB/T 12519-1990). Compared with the original standard, this standard has the following main changes in technical content: - For all the quoted standards, the latest editions referred to applied; - Terms were added; - The instrument model and class designation were added; - Requirements of the instrument function were added; - Requirements of the electromagnetic compatibility (EMC) for instrument were added; - Requirements of the instrument interface, compatibility and interaction were added; - The instrument safety requirements and test method were modified; - The original Appendix A was deleted and the current Appendix A was added. The Appendix A of this standard is informative. This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Technical Committee on Industrial Process Measurement and Control (SAC/TC 124) of Standardization Administration of China. Drafting organizations of this standard: Beijing Analytical Instrument Institute, Shanghai Precision & Scientific Instrument Co., Ltd., Shanghai Lengguang Technology Co., Ltd., Beijing Ruili Analytical Instrument Company, Foshan Analytical Instrument Co., Ltd, Chongqing Chuanyi Analytical Instrument Co., Ltd., Nanjing Analytical Instrument Factory Co., Ltd., Dalian Elite Analytical Instrument Co, Ltd., Shanghai Institute of Measurement and Testing Technology and Beijing Institute of Metrology. Chief drafting staff of this standard: Ma Yajuan, Yin Chuanxin, Qian Guangbei, Wang Jingfeng, Li Peisheng, Hu Tibao, Xu Huaiming, Zhang Xueyun, Zhang Min and Shen Zhengsheng. The previous edition of the standard superseded by this standard is as: - GB/T 12519-1990. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA 中华人民共和国国家标准 GB/T 12519-2010 Supersedes GB/T 12519-1990 General Specification of Analytical Instruments 分析仪器通用技术条件 1. Scope This standard specifies the requirements, test methods, inspection rules, marking, packaging, transport and storage for analytical instrument. This standard is applicable to all types of analytical instruments (hereinafter referred to as instrument). This standard is also applicable to the devices attached to instrument or the devices formed into independent products for sample treatment, preparation, signal processing and transmission and auxiliary analysis. 2. Normative References The following clauses quoted by this standard become the constituent parts of this standard. For dated reference, subsequent amendments to (excluding the correction contents) or revisions of do not applicable to this standard. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 191-2008 Packaging-Pictorial Marking for Handling of Goods (ISO 780: 1997, MOD) GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributes Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection (ISO 2859-1: 1999, IDT) GB/T 2829-2002 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB 4793.1-2007 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use-Part 1: General Requirements (IEC 61010-1: 2001, IDT) GB/T 6592-1996 Expression of the Performance of Electrical and Electronic Measuring Equipment (idt IEC 60359: 1987) GB/T 11606-2007 Methods of Environmental Test for Analytical Instruments GB/T 13384-2008 General Specifications for Packing of Mechanical and Electrical Product GB/T 135966 Analytical Instrument-Vocabulary GB/T 18403.1-2001 Expression of Performance of Gas Analyzers-Part 1:General (eqv IEC 61207-1: 1994) GB/T 20245.1-2006 Expression of Performance of Electrochemical Analyzers Part1: General (IEC: 60746-1: 2003, IDT) JB/T 6241 Analytical Instrument-Method for Product Classification, Designation and Model Codification 3. Terms For the purposes of this standard, the terms and definitions given in GB/T 13966 and the following apply. 3.1 Quality property A description of the technical status of the instrument, which generally is composed of function, technical parameter and performance characteristic. 3.2 Technical parameter A description of the main characteristics of the instrument, such as the measurement object, measurement range, minimum detectable quantity, input quantity, output quantity, etc. of the instrument. Where quantitative assessment is required for a technical parameter of the instrument, the parameter is the performance characteristic. 3.3 Performance characteristic A quantitative description of the service performance of the instrument and the quantitative assessment criteria during the instrument inspection and acceptance, e.g. the sensitivity, accuracy, repeatability and stability of the instrument. In the technical standards of the instrument, each performance characteristic shall have its corresponding test method. 3.4 Function A description of the pathway and mode in which the instrument achieves the required performance characteristic, e.g. the operating software, calibration mode, data processing method, alarm mode and signal transmission form of the instrument. Where quantitative assessment is required for a function of the instrument, such function is the performance characteristic. 3.5 Product standard A document used for fixing the product technical state. It is the basis for the manufacture, inspection, and assessment of the product. The object of product standard may be a product or a class of product. 4. Instrument Classification and Model Designation See JB/T 6241. 5. Requirements 5.1 Working conditions of the instrument The working conditions of the instrument include the reference working condition, normal working condition and extreme working condition. The service conditions are as follows: a) According to the design service conditions of the instrument and by reference to the ambient condition given in Table 1 of GB/T 11606-2007, select all the quantities that will have non-ignorable influence on the instrument quality characteristics, and the reference values or reference ranges as the normal working condition. Where the requirements of GB/T 11606-2007 are not completely met, the difference from the requirements shall be indicated in the document; b) Where the assessment on some quality characteristics of the instrument needs to exclude the influence of environmental factors, a reference working condition shall be given (see Table 2 of GB/T 11606-2007); c) Where necessary, an extreme working condition shall be given. 5.2 Appearance The instrument appearance shall meet the following requirements: a) The instrument appearance shall be in order and clean, and its surface coating and plating shall be free from obvious stripping, scratch, visible base and stain; b) All the nameplates and marks shall be durable and clear and their contents shall meet the requirements of relevant laws, regulations and standards; c) No fasteners shall get loose and all the regulating parts shall be flexible and function normally; d) The parts surfaces shall not be rusted; c) The removable parts of the instrument shall be able to be disassembled and assembled without problems.
Foreword i 1. Scope 2. Normative References 3. Terms 4. Instrument Classification and Model Designation 5. Requirements 6. Test Methods 7. Inspection Rule 8. Marking, Packaging, Transportation and Storage 9. Quality Warranty Appendix A (Informative) Determination of Voltage Value in Dielectric Strength Test
Referred in GB/T 12519-2010:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB/T 2828.1-2003 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)
*GB 4793.1-2007 Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
*GB/T 6592-1996 Expression of the performance of electrical and electronic measuring equipment
*GB/T 11606-2007 Methods of environmental test for analytical instruments
*GB/T 13384-2008 General specifications for packing of mechanical and electrical product
*GBT135966-
*GB/T 18403.1-2001 Expression of performance gas analyzers--Part 1:General
*GB/T 20245.1-2006 Expression of performance of electrochemical analyzers Part1: General
*JB/T 6241-1992 Classification, Designation and Model Drawing-up Method of Analytical Instrument Product
Code of China
Standard
GB/T 12519-2010  General specification of analytical instruments (English Version)
Standard No.GB/T 12519-2010
Statusabolished
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)210.0
Implemented on2011-5-1
Deliveryvia email in 1 business day
Detail of GB/T 12519-2010
Standard No.
GB/T 12519-2010
English Name
General specification of analytical instruments
Chinese Name
分析仪器通用技术条件
Chinese Classification
N53
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2010-12-01
Implemented on
2011-5-1
Status
abolished
Superseded by
GB/T 12519-2021 General specification of analytical instruments
Superseded on
2022-5-1
Abolished on
2022-05-01
Superseding
GB/T 12519-1990 General specification of analytical instruments
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
210.0
Keywords
GB/T 12519-2010, GB 12519-2010, GBT 12519-2010, GB/T12519-2010, GB/T 12519, GB/T12519, GB12519-2010, GB 12519, GB12519, GBT12519-2010, GBT 12519, GBT12519
Introduction of GB/T 12519-2010
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is a revision of and supersedes "General Specification of Analytical Instruments" (GB/T 12519-1990). Compared with the original standard, this standard has the following main changes in technical content: - For all the quoted standards, the latest editions referred to applied; - Terms were added; - The instrument model and class designation were added; - Requirements of the instrument function were added; - Requirements of the electromagnetic compatibility (EMC) for instrument were added; - Requirements of the instrument interface, compatibility and interaction were added; - The instrument safety requirements and test method were modified; - The original Appendix A was deleted and the current Appendix A was added. The Appendix A of this standard is informative. This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Technical Committee on Industrial Process Measurement and Control (SAC/TC 124) of Standardization Administration of China. Drafting organizations of this standard: Beijing Analytical Instrument Institute, Shanghai Precision & Scientific Instrument Co., Ltd., Shanghai Lengguang Technology Co., Ltd., Beijing Ruili Analytical Instrument Company, Foshan Analytical Instrument Co., Ltd, Chongqing Chuanyi Analytical Instrument Co., Ltd., Nanjing Analytical Instrument Factory Co., Ltd., Dalian Elite Analytical Instrument Co, Ltd., Shanghai Institute of Measurement and Testing Technology and Beijing Institute of Metrology. Chief drafting staff of this standard: Ma Yajuan, Yin Chuanxin, Qian Guangbei, Wang Jingfeng, Li Peisheng, Hu Tibao, Xu Huaiming, Zhang Xueyun, Zhang Min and Shen Zhengsheng. The previous edition of the standard superseded by this standard is as: - GB/T 12519-1990. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA 中华人民共和国国家标准 GB/T 12519-2010 Supersedes GB/T 12519-1990 General Specification of Analytical Instruments 分析仪器通用技术条件 1. Scope This standard specifies the requirements, test methods, inspection rules, marking, packaging, transport and storage for analytical instrument. This standard is applicable to all types of analytical instruments (hereinafter referred to as instrument). This standard is also applicable to the devices attached to instrument or the devices formed into independent products for sample treatment, preparation, signal processing and transmission and auxiliary analysis. 2. Normative References The following clauses quoted by this standard become the constituent parts of this standard. For dated reference, subsequent amendments to (excluding the correction contents) or revisions of do not applicable to this standard. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 191-2008 Packaging-Pictorial Marking for Handling of Goods (ISO 780: 1997, MOD) GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributes Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection (ISO 2859-1: 1999, IDT) GB/T 2829-2002 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB 4793.1-2007 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use-Part 1: General Requirements (IEC 61010-1: 2001, IDT) GB/T 6592-1996 Expression of the Performance of Electrical and Electronic Measuring Equipment (idt IEC 60359: 1987) GB/T 11606-2007 Methods of Environmental Test for Analytical Instruments GB/T 13384-2008 General Specifications for Packing of Mechanical and Electrical Product GB/T 135966 Analytical Instrument-Vocabulary GB/T 18403.1-2001 Expression of Performance of Gas Analyzers-Part 1:General (eqv IEC 61207-1: 1994) GB/T 20245.1-2006 Expression of Performance of Electrochemical Analyzers Part1: General (IEC: 60746-1: 2003, IDT) JB/T 6241 Analytical Instrument-Method for Product Classification, Designation and Model Codification 3. Terms For the purposes of this standard, the terms and definitions given in GB/T 13966 and the following apply. 3.1 Quality property A description of the technical status of the instrument, which generally is composed of function, technical parameter and performance characteristic. 3.2 Technical parameter A description of the main characteristics of the instrument, such as the measurement object, measurement range, minimum detectable quantity, input quantity, output quantity, etc. of the instrument. Where quantitative assessment is required for a technical parameter of the instrument, the parameter is the performance characteristic. 3.3 Performance characteristic A quantitative description of the service performance of the instrument and the quantitative assessment criteria during the instrument inspection and acceptance, e.g. the sensitivity, accuracy, repeatability and stability of the instrument. In the technical standards of the instrument, each performance characteristic shall have its corresponding test method. 3.4 Function A description of the pathway and mode in which the instrument achieves the required performance characteristic, e.g. the operating software, calibration mode, data processing method, alarm mode and signal transmission form of the instrument. Where quantitative assessment is required for a function of the instrument, such function is the performance characteristic. 3.5 Product standard A document used for fixing the product technical state. It is the basis for the manufacture, inspection, and assessment of the product. The object of product standard may be a product or a class of product. 4. Instrument Classification and Model Designation See JB/T 6241. 5. Requirements 5.1 Working conditions of the instrument The working conditions of the instrument include the reference working condition, normal working condition and extreme working condition. The service conditions are as follows: a) According to the design service conditions of the instrument and by reference to the ambient condition given in Table 1 of GB/T 11606-2007, select all the quantities that will have non-ignorable influence on the instrument quality characteristics, and the reference values or reference ranges as the normal working condition. Where the requirements of GB/T 11606-2007 are not completely met, the difference from the requirements shall be indicated in the document; b) Where the assessment on some quality characteristics of the instrument needs to exclude the influence of environmental factors, a reference working condition shall be given (see Table 2 of GB/T 11606-2007); c) Where necessary, an extreme working condition shall be given. 5.2 Appearance The instrument appearance shall meet the following requirements: a) The instrument appearance shall be in order and clean, and its surface coating and plating shall be free from obvious stripping, scratch, visible base and stain; b) All the nameplates and marks shall be durable and clear and their contents shall meet the requirements of relevant laws, regulations and standards; c) No fasteners shall get loose and all the regulating parts shall be flexible and function normally; d) The parts surfaces shall not be rusted; c) The removable parts of the instrument shall be able to be disassembled and assembled without problems.
Contents of GB/T 12519-2010
Foreword i 1. Scope 2. Normative References 3. Terms 4. Instrument Classification and Model Designation 5. Requirements 6. Test Methods 7. Inspection Rule 8. Marking, Packaging, Transportation and Storage 9. Quality Warranty Appendix A (Informative) Determination of Voltage Value in Dielectric Strength Test
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 12519-2010, GB 12519-2010, GBT 12519-2010, GB/T12519-2010, GB/T 12519, GB/T12519, GB12519-2010, GB 12519, GB12519, GBT12519-2010, GBT 12519, GBT12519