2026-1-11 10.1.16.22
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 17263-2025
GB/T 17263-2025   Self-ballasted lamps for general lighting service―Performance specifications (English Version)
Standard No.: GB/T 17263-2025 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 19000 words Translation Price(USD):570.0 remind me the price change

Email:

Implemented on:2025-9-1 Delivery: via email in 1~5 business day

→ → →

,,2025-9-1,DFE28DACE7B3201C1741845789039
Standard No.: GB/T 17263-2025
English Name: Self-ballasted lamps for general lighting service―Performance specifications
Chinese Name: 普通照明用自镇流荧光灯性能规范
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2025-02-28
Implemented on: 2025-9-1
Status: valid
Superseding:GB/T 17263-2013 Self-ballasted lamps for general lighting service—Performance requirements
Target Language: English
File Format: PDF
Word Count: 19000 words
Translation Price(USD): 570.0
Delivery: via email in 1~5 business day
GB/T 17263-2025 Self-ballasted lamps for general lighting service―Performance specifications English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 29.140.30 CCS K 71 National Standard of the People's Republic of China GB/T 17263-2025 Replaces GB/T 17263-2013 Self-ballasted lamps for general lighting service - Performance specifications 普通照明用自镇流荧光灯 性能规范 (English Translation) Issue date: 2025-02-28 Implementation date: 2025-09-01 Issued by the State Administration for Market Regulation the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and model 5 Technical requirements 6 Inspection rules 7 Requirements for product production, import or export Annex A (Normative) Start-up time test Annex B (Normative) Rising time test Annex C (Normative) General measurement conditions for photometric and electrical characteristics and requirements for testing equipment Annex D (Normative) Measurement of initial luminous flux, light efficiency and flux maintenance rate Annex E (Normative) Life test Annex F (Normative) Switch tests Bibliography Self-ballasted lamps for general lighting service - Performance specifications 1 Scope This document specifies the classification and model, technical requirements and acceptance rules of self-ballasted lamps for general lighting (hereinafter referred to as "lamps"), and describes the corresponding test methods. This document is suitable for lamps used for general lighting in households and on similar occasions, and the rated voltage is 220V, the frequency is 50Hz, and the lamp holder used meets the requirements of IEC 60061-1. 2 Normative references The following documents contain references which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 2900.65-2023 Electrotechnical terminology - Lighting GB/T 10682-2010 Double-capped fluorescent lamps - Performance specifications GB/T 16844 Self-ballasted lamps for general lighting services - Safety requirements GB/T 17262-2011 Single-capped fluorescent lamps - Performance specification GB 17625.1-2022 Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions (equipment input current≤16 A per phase) GB/T 17743 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment GB/T 18595 Equipment for general lighting purposes-EMC immunity requirements GB/T 19658 Method of measurement of center beam intensity and beam angle(s)of reflector lamps GB/T 22907 The photometry and goniophotometry of luminaires GB/T 23113 Sample preparation for measurement of mercury level in discharge lamp GB/T 26178-2010 The measurement of luminous flux IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps IEC 60901 Single-capped fluorescent lamps - Performance specifications CIE 69 Methods of characterizing illuminance meters and luminance meters: Performance, characteristics and specifications 3 Terms and definitions For the purpose of this document, the terms and definitions defined in GB/T 2900.65-2023 as well as the following apply. 3.1 self-ballasted lamp a lamp containing a lamp cap, a light source and the components necessary to start the light source and maintain a stable ignition point is not removable without damaging its structure 3.2 displacement factor the cosine of the phase angle between the fundamental wave of the supply voltage and the fundamental wave of the supply current, expressed by cos ϕ 1 Note: See Annex F of GB/T 24823-× × × × for the explanation of displacement coefficient. 3.3 type lamps with the same photometric and electrical characteristics regardless of the influence of the lamp head 3.4 rated value, < light sources and related equipment > the quantity used for specification purposes, which is expressly indicated by the manufacturer or responsible seller and determined under standard test conditions Note 1: In order to indicate the "rating" of a particular quantity, the term "value" is replaced by the name of the quantity; For example, rated power, rated voltage, rated current and rated temperature. Note 2: Standard test conditions are given in the relevant standards. 3.5 starting time at the specified temperature of the lamp, turn on the power until the lamp is fully started and maintains the ignition point 3.6 run-up time the time required for the light output to reach 60% of its stable light output after the lamp is turned on 3.7 stabilization time the time required after the lamp is turned on to the stabilization of the photoelectric characteristics of the lamp 3.8 lumens efficiency the ratio of the luminous flux emitted by lamps (including cowled lamps and reflector lamps) to the power consumed Note: The unit is lumens per watt (lm/W). 3.9 beam angle at the angle between two given straight lines on the plane passing through the axis of the beam, the two given straight lines pass through the front center of the lamp and the luminous point whose luminous intensity is 50% of the central light intensity respectively 3.10 lumen maintenance ignition point under specified conditions, the ratio of the luminous flux of the lamp to the initial luminous flux of the lamp at a specific time during its life Note: Expressed as percentage. 3.11 failure the phenomenon that the lamp can't ignite normally or continuously, or its light flux maintenance rate is lower than a specified value 3.12 early failure the failure of the lamp before the ignition point reaches the specified time
Code of China
Standard
GB/T 17263-2025  Self-ballasted lamps for general lighting service―Performance specifications (English Version)
Standard No.GB/T 17263-2025
Statusvalid
LanguageEnglish
File FormatPDF
Word Count19000 words
Price(USD)570.0
Implemented on2025-9-1
Deliveryvia email in 1~5 business day
Detail of GB/T 17263-2025
Standard No.
GB/T 17263-2025
English Name
Self-ballasted lamps for general lighting service―Performance specifications
Chinese Name
普通照明用自镇流荧光灯性能规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-02-28
Implemented on
2025-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 17263-2013 Self-ballasted lamps for general lighting service—Performance requirements
Language
English
File Format
PDF
Word Count
19000 words
Price(USD)
570.0
Keywords
GB/T 17263-2025, GB 17263-2025, GBT 17263-2025, GB/T17263-2025, GB/T 17263, GB/T17263, GB17263-2025, GB 17263, GB17263, GBT17263-2025, GBT 17263, GBT17263
Introduction of GB/T 17263-2025
GB/T 17263-2025 Self-ballasted lamps for general lighting service―Performance specifications English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS 29.140.30 CCS K 71 National Standard of the People's Republic of China GB/T 17263-2025 Replaces GB/T 17263-2013 Self-ballasted lamps for general lighting service - Performance specifications 普通照明用自镇流荧光灯 性能规范 (English Translation) Issue date: 2025-02-28 Implementation date: 2025-09-01 Issued by the State Administration for Market Regulation the Standardization Administration of the People's Republic of China Contents Foreword 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and model 5 Technical requirements 6 Inspection rules 7 Requirements for product production, import or export Annex A (Normative) Start-up time test Annex B (Normative) Rising time test Annex C (Normative) General measurement conditions for photometric and electrical characteristics and requirements for testing equipment Annex D (Normative) Measurement of initial luminous flux, light efficiency and flux maintenance rate Annex E (Normative) Life test Annex F (Normative) Switch tests Bibliography Self-ballasted lamps for general lighting service - Performance specifications 1 Scope This document specifies the classification and model, technical requirements and acceptance rules of self-ballasted lamps for general lighting (hereinafter referred to as "lamps"), and describes the corresponding test methods. This document is suitable for lamps used for general lighting in households and on similar occasions, and the rated voltage is 220V, the frequency is 50Hz, and the lamp holder used meets the requirements of IEC 60061-1. 2 Normative references The following documents contain references which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 2900.65-2023 Electrotechnical terminology - Lighting GB/T 10682-2010 Double-capped fluorescent lamps - Performance specifications GB/T 16844 Self-ballasted lamps for general lighting services - Safety requirements GB/T 17262-2011 Single-capped fluorescent lamps - Performance specification GB 17625.1-2022 Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions (equipment input current≤16 A per phase) GB/T 17743 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment GB/T 18595 Equipment for general lighting purposes-EMC immunity requirements GB/T 19658 Method of measurement of center beam intensity and beam angle(s)of reflector lamps GB/T 22907 The photometry and goniophotometry of luminaires GB/T 23113 Sample preparation for measurement of mercury level in discharge lamp GB/T 26178-2010 The measurement of luminous flux IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps IEC 60901 Single-capped fluorescent lamps - Performance specifications CIE 69 Methods of characterizing illuminance meters and luminance meters: Performance, characteristics and specifications 3 Terms and definitions For the purpose of this document, the terms and definitions defined in GB/T 2900.65-2023 as well as the following apply. 3.1 self-ballasted lamp a lamp containing a lamp cap, a light source and the components necessary to start the light source and maintain a stable ignition point is not removable without damaging its structure 3.2 displacement factor the cosine of the phase angle between the fundamental wave of the supply voltage and the fundamental wave of the supply current, expressed by cos ϕ 1 Note: See Annex F of GB/T 24823-× × × × for the explanation of displacement coefficient. 3.3 type lamps with the same photometric and electrical characteristics regardless of the influence of the lamp head 3.4 rated value, < light sources and related equipment > the quantity used for specification purposes, which is expressly indicated by the manufacturer or responsible seller and determined under standard test conditions Note 1: In order to indicate the "rating" of a particular quantity, the term "value" is replaced by the name of the quantity; For example, rated power, rated voltage, rated current and rated temperature. Note 2: Standard test conditions are given in the relevant standards. 3.5 starting time at the specified temperature of the lamp, turn on the power until the lamp is fully started and maintains the ignition point 3.6 run-up time the time required for the light output to reach 60% of its stable light output after the lamp is turned on 3.7 stabilization time the time required after the lamp is turned on to the stabilization of the photoelectric characteristics of the lamp 3.8 lumens efficiency the ratio of the luminous flux emitted by lamps (including cowled lamps and reflector lamps) to the power consumed Note: The unit is lumens per watt (lm/W). 3.9 beam angle at the angle between two given straight lines on the plane passing through the axis of the beam, the two given straight lines pass through the front center of the lamp and the luminous point whose luminous intensity is 50% of the central light intensity respectively 3.10 lumen maintenance ignition point under specified conditions, the ratio of the luminous flux of the lamp to the initial luminous flux of the lamp at a specific time during its life Note: Expressed as percentage. 3.11 failure the phenomenon that the lamp can't ignite normally or continuously, or its light flux maintenance rate is lower than a specified value 3.12 early failure the failure of the lamp before the ignition point reaches the specified time
Contents of GB/T 17263-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Contact us via WeChat
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 17263-2025, GB 17263-2025, GBT 17263-2025, GB/T17263-2025, GB/T 17263, GB/T17263, GB17263-2025, GB 17263, GB17263, GBT17263-2025, GBT 17263, GBT17263