GB/T 18430.2-2025   Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications (English)
Standard No.: GB/T 18430.2-2025 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 25000 words Translation Price(USD):750.0 remind me the price change

Email:

Implemented on:2026-5-1 Delivery: via email in 1 business day

→ → →

,,2026-5-1,57B72EAF25D0DF351762257485292
Standard No.: GB/T 18430.2-2025
English Name: Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications
Chinese Name: 蒸气压缩循环冷水(热泵)机组 第2部分:户用及类似用途的冷水(热泵)机组
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2025-10-31
Implemented on: 2026-5-1
Status: valid
Superseding:GB/T 18430.2-2016 Water chilling(heat pump)packages using the vapor compression cycle―Part 2:Water chilling (heat pump) packages for household and similar application
Target Language: English
File Format: PDF
Word Count: 25000 words
Translation Price(USD): 750.0
Delivery: via email in 1 business day
Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications 1 Scope This document specifies the types, model designations, basic parameters, technical requirements, inspection rules, as well as marking, packaging, transportation and storage of water chilling (heat pump) packages for household and similar applications, and describes the corresponding test methods. This document is applicable to comfort-type water chilling (heat pump) packages for household and similar applications with a cooling capacity of not more than 50 kW. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2423.17 Environmental testing - Part 2: Test methods - Test Ka: Salt mist GB 2894-2025 Safety colours and safety signs GB/T 4208 Degrees of protection provided by enclosure (IP code) GB/T 4706.1-2024 Safety of household and similar electrical appliances - Part 1: General requirements GB/T 4706.32-2024 Safety of household and similar electrical appliances - Part 32: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers GB/T 9237 Refrigerating systems and heat pumps - Safety and environmental requirements GB/T 9286-2021 Paints and varnishes - Cross-cut test GB/T 10870-2014 The methods of performance test for water chilling (heat pump) packages using the vapor compression cycle GB/T 13306 Plates GB/T 13384 General specifications for packing of mechanical and electrical product GB/T 18430.1-2024 Water chilling (heat pump) packages using the vapor compression cycle - Part 1: Water chilling (heat pump) packages for industrial & commercial and similar application GB/T 21362-2023 Heat pump water heater for commercial & industrial and similar application GB/T 26572 Requirements of concentration limits for certain restricted substances in electrical and electronic products GB/T 29044 Water quality for heating and air conditioning systems JB/T 4330-1999 Determination of noise emitted by refrigerating and air conditioning equipments JB/T 7249 Refrigeration and air conditioning apparatus - Terminology JB/T 10916 Household and similar heating & air conditioning & hot water packages NB/T 47013.8-2012 Nondestructive testing of pressure equipments - Part 8: Leak testing 3 Terms and definitions For the purposes of this document, the terms and definitions given in JB/T 7249 and GB/T 18430.1-2024 as well as the following apply. 3.1 cooling seasonal total load; CSTL total heat removed from the interior of a building by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.2 cooling seasonal total energy; CSTE total electric energy consumed by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.3 cooling seasonal performance factor; CSPF ratio of the total heat removed from the interior to the total electric energy consumed by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.4 heating seasonal total load; HSTL total heat delivered to the interior of a building by the package during heating operation in the heating season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.5 heating seasonal total energy; HSTE total electric energy consumed by the package during heating operation in the heating season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.6 heating seasonal performance factor; HSPF ratio of the total heat delivered to the interior to the total electric energy consumed by the package during heating operation in the heating season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.7 annual performance factor; APF ratio of the sum of heat removed from the interior during cooling and heat delivered to the interior during heating to the total electric energy consumed by the package over a year consisting of one consecutive cooling season and one heating season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.8 useful water temperature Tm minimum water temperature that contributes to the useful energy content when water is drawn off in the water use model Note: The unit is degree Celsius (°C). 3.9 useful water flow f
Contents Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Types and basic parameters 5 Technical requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Annex A (Normative) Special requirements and test methods for packages with heat recovery function Annex B (Normative) Special requirements and test methods for packages with cold storage function Annex C (Normative) Test and calculation methods for performance of domestic hot water function Annex D (Normative) Test and calculation method for seasonal performance of air-cooled package Annex E (Normative) Comparison table for Category B test items Bibliography
GB/T 18430.2-2025 is referred in:
*GB/T 10870-2014/XG1-2015 The methods of performance test for water chilling(heat pump) packages using the vaper compression cycle , includes Amendment 1
Code of China
Standard
GB/T 18430.2-2025  Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications (English)
Standard No.GB/T 18430.2-2025
Statusvalid
LanguageEnglish
File FormatPDF
Word Count25000 words
Translation Price(USD)750.0
Implemented on2026-5-1
Deliveryvia email in 1 business day
Detail of GB/T 18430.2-2025
Standard No.
GB/T 18430.2-2025
English Name
Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications
Chinese Name
蒸气压缩循环冷水(热泵)机组 第2部分:户用及类似用途的冷水(热泵)机组
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2025-10-31
Implemented on
2026-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 18430.2-2016 Water chilling(heat pump)packages using the vapor compression cycle―Part 2:Water chilling (heat pump) packages for household and similar application
Language
English
File Format
PDF
Word Count
25000 words
Translation Price(USD)
750.0
Keywords
GB/T 18430.2-2025, GB 18430.2-2025, GBT 18430.2-2025, GB/T18430.2-2025, GB/T 18430.2, GB/T18430.2, GB18430.2-2025, GB 18430.2, GB18430.2, GBT18430.2-2025, GBT 18430.2, GBT18430.2
Introduction of GB/T 18430.2-2025
Water chilling (heat pump) packages using the vapor compression cycle - Part 2: Water chilling (heat pump) packages for household and similar applications 1 Scope This document specifies the types, model designations, basic parameters, technical requirements, inspection rules, as well as marking, packaging, transportation and storage of water chilling (heat pump) packages for household and similar applications, and describes the corresponding test methods. This document is applicable to comfort-type water chilling (heat pump) packages for household and similar applications with a cooling capacity of not more than 50 kW. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2423.17 Environmental testing - Part 2: Test methods - Test Ka: Salt mist GB 2894-2025 Safety colours and safety signs GB/T 4208 Degrees of protection provided by enclosure (IP code) GB/T 4706.1-2024 Safety of household and similar electrical appliances - Part 1: General requirements GB/T 4706.32-2024 Safety of household and similar electrical appliances - Part 32: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers GB/T 9237 Refrigerating systems and heat pumps - Safety and environmental requirements GB/T 9286-2021 Paints and varnishes - Cross-cut test GB/T 10870-2014 The methods of performance test for water chilling (heat pump) packages using the vapor compression cycle GB/T 13306 Plates GB/T 13384 General specifications for packing of mechanical and electrical product GB/T 18430.1-2024 Water chilling (heat pump) packages using the vapor compression cycle - Part 1: Water chilling (heat pump) packages for industrial & commercial and similar application GB/T 21362-2023 Heat pump water heater for commercial & industrial and similar application GB/T 26572 Requirements of concentration limits for certain restricted substances in electrical and electronic products GB/T 29044 Water quality for heating and air conditioning systems JB/T 4330-1999 Determination of noise emitted by refrigerating and air conditioning equipments JB/T 7249 Refrigeration and air conditioning apparatus - Terminology JB/T 10916 Household and similar heating & air conditioning & hot water packages NB/T 47013.8-2012 Nondestructive testing of pressure equipments - Part 8: Leak testing 3 Terms and definitions For the purposes of this document, the terms and definitions given in JB/T 7249 and GB/T 18430.1-2024 as well as the following apply. 3.1 cooling seasonal total load; CSTL total heat removed from the interior of a building by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.2 cooling seasonal total energy; CSTE total electric energy consumed by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.3 cooling seasonal performance factor; CSPF ratio of the total heat removed from the interior to the total electric energy consumed by the package during cooling operation in the cooling season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.4 heating seasonal total load; HSTL total heat delivered to the interior of a building by the package during heating operation in the heating season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.5 heating seasonal total energy; HSTE total electric energy consumed by the package during heating operation in the heating season Note: The unit is kilowatt-hour (kW·h). The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.6 heating seasonal performance factor; HSPF ratio of the total heat delivered to the interior to the total electric energy consumed by the package during heating operation in the heating season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.7 annual performance factor; APF ratio of the sum of heat removed from the interior during cooling and heat delivered to the interior during heating to the total electric energy consumed by the package over a year consisting of one consecutive cooling season and one heating season Note: The unit is kilowatt-hour per kilowatt-hour [(kW·h)/(kW·h)]. The value shall be retained with 2 decimal places (at least 3 decimal places when used as a process parameter). 3.8 useful water temperature Tm minimum water temperature that contributes to the useful energy content when water is drawn off in the water use model Note: The unit is degree Celsius (°C). 3.9 useful water flow f
Contents of GB/T 18430.2-2025
Contents Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Types and basic parameters 5 Technical requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Annex A (Normative) Special requirements and test methods for packages with heat recovery function Annex B (Normative) Special requirements and test methods for packages with cold storage function Annex C (Normative) Test and calculation methods for performance of domestic hot water function Annex D (Normative) Test and calculation method for seasonal performance of air-cooled package Annex E (Normative) Comparison table for Category B test items Bibliography