2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 20319-2006
GB/T 20319-2006   Code for acceptance of Wind turbines generator systems (English Version)
Standard No.: GB/T 20319-2006 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2500 words Translation Price(USD):344.0 remind me the price change

Email:

Implemented on:2007-1-1 Delivery: via email in 1 business day

→ → →

,2018-2-1,2007-1-1,14113818181802981F3B69B87101B
Standard No.: GB/T 20319-2006
English Name: Code for acceptance of Wind turbines generator systems
Chinese Name: 风力发电机组 验收规范
Chinese Classification: F11    Wind energy
Professional Classification: GB    National Standard
Source Content Issued by: SAC
Issued on: 2006-7-20
Implemented on: 2007-1-1
Status: superseded
Superseded by:GB/T 20319-2017 Wind turbine generator systems. Specification for acceptance
Superseded on:2018-2-1
Target Language: English
File Format: PDF
Word Count: 2500 words
Translation Price(USD): 344.0
Delivery: via email in 1 business day
This standard specifies the general principles and contents of handover and acceptance of project carried out by the supplier and the purchaser after site installation, commissioning and normal power generation of wind turbine generator system. It aims at providing unified method for the determination of safety, power characteristic, power quality, noise and other performance of the unit. This standard is applicable to the finalized wind turbine generator system with swept area of wind rotor greater than or equal to 40m2, while not applicable to the acceptance of developed sample machine and newly developed product.
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Acceptance Procedure 4.1 General 4.2 Site Commissioning 4.3 Test Run 4.4 Pre-acceptance 4.5 Operation and Maintenance 4.6 Final Acceptance 5 Acceptance Test Method 5.1 General 5.2 Bolted Connection Inspection 5.3 Measurement of Grounding Resistance 5.4 Inspection and Test of Control Functions 5.5 Inspection and Test of Safety Protection Function 5.6 Anti-corrosion Inspection 5.7 Availability Assessment 5.8 Characteristic Testing of Unit Power 5.9 Measurement and Assessment of Power Quality 5.10 Noise Measurement 6 Acceptance Documents 6.1 General 6.2 Project Overview 6.3 Completion Drawing 6.4 Quality Documents of Wind Turbine Generator System 6.5 Acceptance Documents of Installation Construction Project 6.6 Commissioning and Test Run Reports of Wind Turbine Generator System 6.7 Acceptance Test Report 6.8 Conclusion and Suggestion of Final Acceptance 6.9 Others
GB/T 20319-2006 is referred in:
* GB/Z 25458-2010 Rules and procedures for conformity testing and certification of wind turbine generator system
Code of China
Standard
GB/T 20319-2006  Code for acceptance of Wind turbines generator systems (English Version)
Standard No.GB/T 20319-2006
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count2500 words
Price(USD)344.0
Implemented on2007-1-1
Deliveryvia email in 1 business day
Detail of GB/T 20319-2006
Standard No.
GB/T 20319-2006
English Name
Code for acceptance of Wind turbines generator systems
Chinese Name
风力发电机组 验收规范
Chinese Classification
F11
Professional Classification
GB
ICS Classification
Issued by
SAC
Issued on
2006-7-20
Implemented on
2007-1-1
Status
superseded
Superseded by
GB/T 20319-2017 Wind turbine generator systems. Specification for acceptance
Superseded on
2018-2-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
2500 words
Price(USD)
344.0
Keywords
GB/T 20319-2006, GB 20319-2006, GBT 20319-2006, GB/T20319-2006, GB/T 20319, GB/T20319, GB20319-2006, GB 20319, GB20319, GBT20319-2006, GBT 20319, GBT20319
Introduction of GB/T 20319-2006
This standard specifies the general principles and contents of handover and acceptance of project carried out by the supplier and the purchaser after site installation, commissioning and normal power generation of wind turbine generator system. It aims at providing unified method for the determination of safety, power characteristic, power quality, noise and other performance of the unit. This standard is applicable to the finalized wind turbine generator system with swept area of wind rotor greater than or equal to 40m2, while not applicable to the acceptance of developed sample machine and newly developed product.
Contents of GB/T 20319-2006
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Acceptance Procedure 4.1 General 4.2 Site Commissioning 4.3 Test Run 4.4 Pre-acceptance 4.5 Operation and Maintenance 4.6 Final Acceptance 5 Acceptance Test Method 5.1 General 5.2 Bolted Connection Inspection 5.3 Measurement of Grounding Resistance 5.4 Inspection and Test of Control Functions 5.5 Inspection and Test of Safety Protection Function 5.6 Anti-corrosion Inspection 5.7 Availability Assessment 5.8 Characteristic Testing of Unit Power 5.9 Measurement and Assessment of Power Quality 5.10 Noise Measurement 6 Acceptance Documents 6.1 General 6.2 Project Overview 6.3 Completion Drawing 6.4 Quality Documents of Wind Turbine Generator System 6.5 Acceptance Documents of Installation Construction Project 6.6 Commissioning and Test Run Reports of Wind Turbine Generator System 6.7 Acceptance Test Report 6.8 Conclusion and Suggestion of Final Acceptance 6.9 Others
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 20319-2006, GB 20319-2006, GBT 20319-2006, GB/T20319-2006, GB/T 20319, GB/T20319, GB20319-2006, GB 20319, GB20319, GBT20319-2006, GBT 20319, GBT20319