2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 21246-2007
GB/T 21246-2007   Measurement method for cathodic protection parameters of buried steel pipelines (English Version)
Standard No.: GB/T 21246-2007 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 18500 words Translation Price(USD):550.0 remind me the price change

Email:

Implemented on:2008-5-1 Delivery: via email in 1 business day

→ → →

2021-06-01 ,2021-6-1,2008-5-1,1411381818301344C834CA5591324
Standard No.: GB/T 21246-2007
English Name: Measurement method for cathodic protection parameters of buried steel pipelines
Chinese Name: 埋地钢质管道阴极保护参数测量方法
Chinese Classification: E98    Oil and gas gathering and transportation equipment
Professional Classification: GB    National Standard
ICS Classification: 75.180.30 75.180.30    Volumetric equipment and measurements 75.180.30
Source Content Issued by: AQSIQ; SAC
Issued on: 2007-11-01
Implemented on: 2008-5-1
Status: superseded
Superseded by:GB/T 21246-2020 Measurement method for cathodic protection parameters of buried steel pipelines
Superseded on:2021-6-1
Abolished on:2021-06-01
Target Language: English
File Format: PDF
Word Count: 18500 words
Translation Price(USD): 550.0
Delivery: via email in 1 business day
1 Scope This standard specifies site measurement method for cathodic protection parameters of buried steel pipeline. This standard is applicable to site measurement for cathodic protection parameters of buried steel pipeline. Measurement for external bottom plate of steel storage tank, steel pipeline in beach and cathodic protection parameters of structure may be adopted by reference. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to these specifications are encouraged to research whether the latest editions of these labels are applied or not. For undated references, the latest edition of the normative document is applicable. JJG 123 Verification Regulation of D.C. Potentiometers JJG 124 Verification Regulation of Amperemeters Voltmeters Wattmeters and Ohmmeters JJG 123 Verification Regulation of DC Digital Voltmeter JJG 123 Verification Regulation of Earth Resistance Meter JJG 123 Verification Regulation of DC Digital Amperemetor JJG 622 Verification Regulation of Megohmmeter 3 Terms and Definitions For the purpose of this standard, the following terms and definitions apply. 3.1 The pipe-to-soil potential It refers to potential difference between pipeline and its adjacent electrolyte (soil). 3.2 On potential It refers to potential of measured structure on the electrolyte (soil) where the cathodic protection system is persistently operated. 3.3 IR drop It refers to voltage drop produced within electrolyte (soil) between reference electrode and metal pipeline due to current flow according to Ohm's law. 3.4 Off potential It refers to potential of measured structure on the electrolyte (soil) at the instant power failure. Note: Generally, measurement shall be immediately carried out after cathodic protection current is cut off and before polarization potential has attenuated. 3.5 Voltage spiking It refers to transient potential fluctuation on pipeline caused by transient process at the interrupted or applied instant of cathodic protection current. 3.6 Close-interval potential survey (CIPS) It refers to such a kind of method that the reference electrode is moved in close-interval (generally 1m~3m) along ground surface at the top of pipe to measure the pipe-to-soil potential. 3.7 Intensive measurement technique It refers to the technique that the pipe-to-soil potential and soil potential gradient in vertical direction are measured simultaneously. Note: intensive measurement technique may identify defect in anti-corrosion coating and can calculate the potential after all the IR drops are eliminated at the defect area. 3.8 Equalising current It is also referred to as "secondary current" and refers to current between polarization difference positions of structure after protection current is interrupted; equalising current may be the error source of IR drop potential. 3.9 Reference electrode method remote from pipeline It refers to such method that the reference electrode is placed in soil relatively remote measured pipeline (ground potential is nulling) to measure the pipe-to-soil potential. 3.10 Remote earth It refers to such area where any measurable voltage drop caused by current flow is absent between any two points. 3.11 Coating resistivity It refers to product of coating resistance and coating surface area. 3.12 Coating resistance
1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirement 5 Potential Measurement 6 Output Current of Sacrificial Anode 7 In-line Current 8 Resistivity of External Coating on Pipeline 9 Insulation Property of Insulated Joint (Flange) 10 Grounding Resistance 11 Soil Resistivity 12 Ground Leak Detection of External Coating on Pipeline
Referred in GB/T 21246-2007:
*JJG 123-2005 Measuring Ruler for Difference of Wheels Set Position and Brake Discs Set Position of Railway Vehciles
*JJG 124-2005 Verification Regulation of Amperemeters Voltmeters Wattmeters and Ohmmeters
*JJG 123-2005 Measuring Ruler for Difference of Wheels Set Position and Brake Discs Set Position of Railway Vehciles
*JJG 123-2005 Measuring Ruler for Difference of Wheels Set Position and Brake Discs Set Position of Railway Vehciles
*JJG 123-2005 Measuring Ruler for Difference of Wheels Set Position and Brake Discs Set Position of Railway Vehciles
*JJG 622-1997 Verification regulation of megohmmeter
Code of China
Standard
GB/T 21246-2007  Measurement method for cathodic protection parameters of buried steel pipelines (English Version)
Standard No.GB/T 21246-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count18500 words
Price(USD)550.0
Implemented on2008-5-1
Deliveryvia email in 1 business day
Detail of GB/T 21246-2007
Standard No.
GB/T 21246-2007
English Name
Measurement method for cathodic protection parameters of buried steel pipelines
Chinese Name
埋地钢质管道阴极保护参数测量方法
Chinese Classification
E98
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2007-11-01
Implemented on
2008-5-1
Status
superseded
Superseded by
GB/T 21246-2020 Measurement method for cathodic protection parameters of buried steel pipelines
Superseded on
2021-6-1
Abolished on
2021-06-01
Superseding
Language
English
File Format
PDF
Word Count
18500 words
Price(USD)
550.0
Keywords
GB/T 21246-2007, GB 21246-2007, GBT 21246-2007, GB/T21246-2007, GB/T 21246, GB/T21246, GB21246-2007, GB 21246, GB21246, GBT21246-2007, GBT 21246, GBT21246
Introduction of GB/T 21246-2007
1 Scope This standard specifies site measurement method for cathodic protection parameters of buried steel pipeline. This standard is applicable to site measurement for cathodic protection parameters of buried steel pipeline. Measurement for external bottom plate of steel storage tank, steel pipeline in beach and cathodic protection parameters of structure may be adopted by reference. 2 Normative References The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to these specifications are encouraged to research whether the latest editions of these labels are applied or not. For undated references, the latest edition of the normative document is applicable. JJG 123 Verification Regulation of D.C. Potentiometers JJG 124 Verification Regulation of Amperemeters Voltmeters Wattmeters and Ohmmeters JJG 123 Verification Regulation of DC Digital Voltmeter JJG 123 Verification Regulation of Earth Resistance Meter JJG 123 Verification Regulation of DC Digital Amperemetor JJG 622 Verification Regulation of Megohmmeter 3 Terms and Definitions For the purpose of this standard, the following terms and definitions apply. 3.1 The pipe-to-soil potential It refers to potential difference between pipeline and its adjacent electrolyte (soil). 3.2 On potential It refers to potential of measured structure on the electrolyte (soil) where the cathodic protection system is persistently operated. 3.3 IR drop It refers to voltage drop produced within electrolyte (soil) between reference electrode and metal pipeline due to current flow according to Ohm's law. 3.4 Off potential It refers to potential of measured structure on the electrolyte (soil) at the instant power failure. Note: Generally, measurement shall be immediately carried out after cathodic protection current is cut off and before polarization potential has attenuated. 3.5 Voltage spiking It refers to transient potential fluctuation on pipeline caused by transient process at the interrupted or applied instant of cathodic protection current. 3.6 Close-interval potential survey (CIPS) It refers to such a kind of method that the reference electrode is moved in close-interval (generally 1m~3m) along ground surface at the top of pipe to measure the pipe-to-soil potential. 3.7 Intensive measurement technique It refers to the technique that the pipe-to-soil potential and soil potential gradient in vertical direction are measured simultaneously. Note: intensive measurement technique may identify defect in anti-corrosion coating and can calculate the potential after all the IR drops are eliminated at the defect area. 3.8 Equalising current It is also referred to as "secondary current" and refers to current between polarization difference positions of structure after protection current is interrupted; equalising current may be the error source of IR drop potential. 3.9 Reference electrode method remote from pipeline It refers to such method that the reference electrode is placed in soil relatively remote measured pipeline (ground potential is nulling) to measure the pipe-to-soil potential. 3.10 Remote earth It refers to such area where any measurable voltage drop caused by current flow is absent between any two points. 3.11 Coating resistivity It refers to product of coating resistance and coating surface area. 3.12 Coating resistance
Contents of GB/T 21246-2007
1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirement 5 Potential Measurement 6 Output Current of Sacrificial Anode 7 In-line Current 8 Resistivity of External Coating on Pipeline 9 Insulation Property of Insulated Joint (Flange) 10 Grounding Resistance 11 Soil Resistivity 12 Ground Leak Detection of External Coating on Pipeline
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 21246-2007, GB 21246-2007, GBT 21246-2007, GB/T21246-2007, GB/T 21246, GB/T21246, GB21246-2007, GB 21246, GB21246, GBT21246-2007, GBT 21246, GBT21246