2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 25915.4-2010
GB/T 25915.4-2010   Cleanrooms and associated controlled environments—Part 4:Design,construction and start-up (English Version)
Standard No.: GB/T 25915.4-2010 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 21000 words Translation Price(USD):570.0 remind me the price change

Email:

Implemented on:2011-6-1 Delivery: via email in 1 business day

→ → →

,,2011-6-1,1411381818878616E7D3B92891725
Standard No.: GB/T 25915.4-2010
English Name: Cleanrooms and associated controlled environments—Part 4:Design,construction and start-up
Chinese Name: 洁净室及相关受控环境 第4部分:设计、建造、启动
Chinese Classification: C70    Industrial dust and gas prevention technology
Professional Classification: GB    National Standard
ICS Classification: 13.040.35 13.040.35    Cleanrooms and associated controlled environments 13.040.35
Source Content Issued by: AQSIQ
Issued on: 2011-1-14
Implemented on: 2011-6-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 21000 words
Translation Price(USD): 570.0
Delivery: via email in 1 business day
GB/T 25915.4-2010 Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up 1 Scope This part of GB/T 25915 specifies requirements for the design and construction of cleanroom installations but does not prescribe specific technological or contractual means to meet these requirements. It is intended for use by purchasers, suppliers and designers of cleanroom installations and provides a checklist of important parameters of performance. Construction guidance is provided, including requirements for start-up and verification. Basic elements of design and construction needed to ensure continued satisfactory operation are identified through the consideration of relevant aspects of operation and maintenance. Note: Further guidance in respect of the above requirements is given in Annexes A to H. Other parts of GB/T 25915 may provide complementary information. Application of this part of GB/T 25915 is restricted in the following: ——user requirements are represented by purchaser or specifier; ——specific processes to be accommodated in the cleanroom installation are not specified; ——fire and safety regulations are not considered specifically; the appropriate national and local requirements shall be respected; ——process media and utility services are only considered with respect to their routing between and in the different zones of cleanliness; ——regarding initial operation and maintenance, only cleanroom construction-specific requirements are considered. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 25915.1-2010 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness (ISO 14644-1:1999, IDT) GB/T 25915.2-2010 Cleanrooms and associated controlled environments - Part 2: Specifications for testing and monitoring to prove continued compliance with GB/T 25915.1 (ISO 14644-2:2000, IDT) GB/T 25915.3-2010 Cleanrooms and associated controlled environments - Part 3: Test methods (ISO 14644-3:2005, IDT) GB/T 25916.1-2010 Cleanrooms and associated controlled environments - Biocontamination control - Part 1: General principles and methods (ISO 14698-1: 2003, IDT) GB/T 25916.2-2010 Cleanrooms and associated controlled environments - Biocontamination control - Part 2: Evaluation and interpretation of biocontamination data (ISO 14698-2: 2003, IDT) 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 25915.1-2010 and the following apply. 3.1 changing room room where people using a cleanroom may change into, or out of, cleanroom apparel 3.2 clean air device stand-alone equipment for treating and distributing clean air to achieve defined environmental conditions 3.3 cleanliness condition of a product, surface, device, gas, fluid, etc. with a defined level of contamination Note: Contamination may be particulate, non-particulate, biological, molecular or of other consistency. 3.4 commissioning planned and documented series of inspections, adjustments and tests carried out systematically to set the installation into correct technical operation as specified 3.5 contaminant any particulate, molecular, non- particulate and biological entity that can adversely affect the product or process
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Requirements 5 Planning and design 6 Construction and start-up 7 Testing and approval 8 Documentation Annex A (informative) Control and segregation concepts Annex B (Informative) Classification examples Annex C (Informative) Approval of an installation Annex D (Informative) Layout of an installation Annex E (Informative) Construction and materials Annex F (informative) Environmental control of cleanrooms Annex G (informative) Control of air cleanliness Annex H (informative) Additional specification of requirements to be agreed upon between purchaser/user and designer/supplier Bibliography
Referred in GB/T 25915.4-2010:
*GB/T 25915.1-2010 Cleanrooms and associated controlled environments—Part 1:Classification of air cleanliness
*GB/T 25915.2-2010 Cleanrooms and associated controlled environments—Part 2:Specifications for testing and monitoring to prove continued compliance with GB/T 25915.1
*GB/T 25915.3-2010 Cleanrooms and associated controlled environments—Part 3:Test methods
*GB/T 25916.1-2010 Cleanrooms and associated controlled environments—Biocontamination Control—Part 1:General principles and methods
*GB/T 25916.2-2010 Cleanrooms and associated controlled environments—Biocontamination control—Part 2:Evaluation and interpretation of biocontamination data
GB/T 25915.4-2010 is referred in:
*GB/T 25915.5-2010 Cleanrooms and associated controlled environments—Part 5:Operations
*GB/T 25915.7-2010 Cleanrooms and associated controlled environments—Part 7:Separative devices (clean air hoods,gloveboxes,isolators and minienvironments)
*GB/T 25916.1-2010 Cleanrooms and associated controlled environments—Biocontamination Control—Part 1:General principles and methods
*GB/T 25915.3-2010 Cleanrooms and associated controlled environments—Part 3:Test methods
Code of China
Standard
GB/T 25915.4-2010   Cleanrooms and associated controlled environments—Part 4:Design,construction and start-up (English Version)
Standard No.GB/T 25915.4-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Price(USD)570.0
Implemented on2011-6-1
Deliveryvia email in 1 business day
Detail of GB/T 25915.4-2010
Standard No.
GB/T 25915.4-2010
English Name
Cleanrooms and associated controlled environments—Part 4:Design,construction and start-up
Chinese Name
洁净室及相关受控环境 第4部分:设计、建造、启动
Chinese Classification
C70
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
2011-1-14
Implemented on
2011-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
21000 words
Price(USD)
570.0
Keywords
GB/T 25915.4-2010, GB 25915.4-2010, GBT 25915.4-2010, GB/T25915.4-2010, GB/T 25915.4, GB/T25915.4, GB25915.4-2010, GB 25915.4, GB25915.4, GBT25915.4-2010, GBT 25915.4, GBT25915.4
Introduction of GB/T 25915.4-2010
GB/T 25915.4-2010 Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up 1 Scope This part of GB/T 25915 specifies requirements for the design and construction of cleanroom installations but does not prescribe specific technological or contractual means to meet these requirements. It is intended for use by purchasers, suppliers and designers of cleanroom installations and provides a checklist of important parameters of performance. Construction guidance is provided, including requirements for start-up and verification. Basic elements of design and construction needed to ensure continued satisfactory operation are identified through the consideration of relevant aspects of operation and maintenance. Note: Further guidance in respect of the above requirements is given in Annexes A to H. Other parts of GB/T 25915 may provide complementary information. Application of this part of GB/T 25915 is restricted in the following: ——user requirements are represented by purchaser or specifier; ——specific processes to be accommodated in the cleanroom installation are not specified; ——fire and safety regulations are not considered specifically; the appropriate national and local requirements shall be respected; ——process media and utility services are only considered with respect to their routing between and in the different zones of cleanliness; ——regarding initial operation and maintenance, only cleanroom construction-specific requirements are considered. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 25915.1-2010 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness (ISO 14644-1:1999, IDT) GB/T 25915.2-2010 Cleanrooms and associated controlled environments - Part 2: Specifications for testing and monitoring to prove continued compliance with GB/T 25915.1 (ISO 14644-2:2000, IDT) GB/T 25915.3-2010 Cleanrooms and associated controlled environments - Part 3: Test methods (ISO 14644-3:2005, IDT) GB/T 25916.1-2010 Cleanrooms and associated controlled environments - Biocontamination control - Part 1: General principles and methods (ISO 14698-1: 2003, IDT) GB/T 25916.2-2010 Cleanrooms and associated controlled environments - Biocontamination control - Part 2: Evaluation and interpretation of biocontamination data (ISO 14698-2: 2003, IDT) 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 25915.1-2010 and the following apply. 3.1 changing room room where people using a cleanroom may change into, or out of, cleanroom apparel 3.2 clean air device stand-alone equipment for treating and distributing clean air to achieve defined environmental conditions 3.3 cleanliness condition of a product, surface, device, gas, fluid, etc. with a defined level of contamination Note: Contamination may be particulate, non-particulate, biological, molecular or of other consistency. 3.4 commissioning planned and documented series of inspections, adjustments and tests carried out systematically to set the installation into correct technical operation as specified 3.5 contaminant any particulate, molecular, non- particulate and biological entity that can adversely affect the product or process
Contents of GB/T 25915.4-2010
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 Requirements 5 Planning and design 6 Construction and start-up 7 Testing and approval 8 Documentation Annex A (informative) Control and segregation concepts Annex B (Informative) Classification examples Annex C (Informative) Approval of an installation Annex D (Informative) Layout of an installation Annex E (Informative) Construction and materials Annex F (informative) Environmental control of cleanrooms Annex G (informative) Control of air cleanliness Annex H (informative) Additional specification of requirements to be agreed upon between purchaser/user and designer/supplier Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 25915.4-2010, GB 25915.4-2010, GBT 25915.4-2010, GB/T25915.4-2010, GB/T 25915.4, GB/T25915.4, GB25915.4-2010, GB 25915.4, GB25915.4, GBT25915.4-2010, GBT 25915.4, GBT25915.4