2026-5-28 10.8.143.123
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 26875.5-2026
GB/T 26875.5-2026   Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software (English)
Standard No.: GB/T 26875.5-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2027-5-1 Delivery: via email in 1~3 business day

→ → →

,,2027-5-1,8277DE3E0C0A85DA1778135012928
Standard No.: GB/T 26875.5-2026
English Name: Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software
Chinese Name: 城市消防远程监控系统 第5部分:受理软件功能要求
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-04-30
Implemented on: 2027-5-1
Status: to be valid
Superseding:GB/T 26875.5-2011
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1~3 business day
GB/T 26875.5-2026 Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 26875.5-2026 Remote-monitoring system of urban fire protection - Part 5: Functional requirements for receiving software 城市消防远程监控系统 第5部分:受理软件功能要求 Issue date: 2026-04-30 Implementation date: 2026-10-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Functional Requirements 5 Conformity Evaluation Bibliography Remote monitoring system of urban fire protection — Part 5: Functional requirements for receiving software 1 Scope This document specifies the functional requirements and conformity evaluation for the receiving software used at manual receiving agent seats on the application support platform in a remote monitoring system of urban fire protection. This document applies to the design, development and testing of the receiving software (hereinafter referred to as the “software”) used at manual receiving agent seats on the application support platform in a remote monitoring system of urban fire protection (hereinafter referred to as the “system”). 2 Normative References The following documents are essential for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 25000.51-2016 Systems and software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE) — Part 51: Requirements for quality of Ready to Use Software Product (RUSP) and instructions for testing GB/T 26875.1 Remote monitoring system of urban fire protection — Part 1: General technical requirements 3 Terms and Definitions The terms and definitions given in GB/T 26875.1 apply to this document. 4 Functional Requirements 4.1 After the software is started and run or after a login operation, it shall automatically enter the receiving working state. 4.2 The software shall have operation confirmation prompts for functions such as parameter configuration, shift handover, onduty/offduty state switching, and exiting. 4.3 The software interface shall be displayed in Chinese. It shall have display interfaces for text information, geographic information and video information, and shall display, but not be limited to, the following information: a) Unreceived information; b) Date and time information; c) Software version information; d) Receiving agent seat and receiving agent information; e) Offduty or onduty status information of receiving agents; f) Communication connection status information. Among the above information, the content in a) shall not be covered. 4.4 When two or more agent seats are online simultaneously receiving information, the software shall have functions for the assignment management of unreceived information to agent seats, for taking over information, and for transferring and pushing information. 4.5 During information processing, there shall be an indication of the receiving process. For improper operations, there shall be an alarm prompt. 4.6 The display interfaces for text information, geographic information and video information shall have associated operation functions. When processing newly received information on the text information display interface, the geographic information display interface and the video information display interface shall automatically switch to the corresponding geographic location and video interface. When performing a positioning operation on the geographic information display interface, the relevant location information shall be able to be extracted into the text information display interface. 4.7 The software shall be able to record and query the offduty and onduty times of receiving agents, the shift handover times of receiving agents, and duty notes, and shall have a log viewing function. The operation log shall include, but not be limited to, the start and exit times of the software, the times and content of parameter configuration changes, the times and content of software error prompts, and the times and status information of communication connection status changes. 4.8 The software shall have a time synchronisation function. The time deviation after time synchronisation shall comply with the provisions of GB/T 26875.1. 4.9 The software shall be able to receive, display, process and query the fire facility operational status information of networked units. 4.10 The software shall be able to display and query the fire safety management information of networked units, and shall be able to monitor and process the dynamic management information of the fire safety management information of networked units.
Code of China
Standard
GB/T 26875.5-2026  Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software (English Version)
Standard No.GB/T 26875.5-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)270.0
Implemented on2027-5-1
Deliveryvia email in 1~3 business day
Detail of GB/T 26875.5-2026
Standard No.
GB/T 26875.5-2026
English Name
Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software
Chinese Name
城市消防远程监控系统 第5部分:受理软件功能要求
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-04-30
Implemented on
2027-5-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 26875.5-2011
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Keywords
GB/T 26875.5-2026, GB 26875.5-2026, GBT 26875.5-2026, GB/T26875.5-2026, GB/T 26875.5, GB/T26875.5, GB26875.5-2026, GB 26875.5, GB26875.5, GBT26875.5-2026, GBT 26875.5, GBT26875.5
Introduction of GB/T 26875.5-2026
GB/T 26875.5-2026 Remote-monitoring system of urban fire protection—Part 5:Functional requirements for receiving software English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 26875.5-2026 Remote-monitoring system of urban fire protection - Part 5: Functional requirements for receiving software 城市消防远程监控系统 第5部分:受理软件功能要求 Issue date: 2026-04-30 Implementation date: 2026-10-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative References 3 Terms and Definitions 4 Functional Requirements 5 Conformity Evaluation Bibliography Remote monitoring system of urban fire protection — Part 5: Functional requirements for receiving software 1 Scope This document specifies the functional requirements and conformity evaluation for the receiving software used at manual receiving agent seats on the application support platform in a remote monitoring system of urban fire protection. This document applies to the design, development and testing of the receiving software (hereinafter referred to as the “software”) used at manual receiving agent seats on the application support platform in a remote monitoring system of urban fire protection (hereinafter referred to as the “system”). 2 Normative References The following documents are essential for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 25000.51-2016 Systems and software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE) — Part 51: Requirements for quality of Ready to Use Software Product (RUSP) and instructions for testing GB/T 26875.1 Remote monitoring system of urban fire protection — Part 1: General technical requirements 3 Terms and Definitions The terms and definitions given in GB/T 26875.1 apply to this document. 4 Functional Requirements 4.1 After the software is started and run or after a login operation, it shall automatically enter the receiving working state. 4.2 The software shall have operation confirmation prompts for functions such as parameter configuration, shift handover, onduty/offduty state switching, and exiting. 4.3 The software interface shall be displayed in Chinese. It shall have display interfaces for text information, geographic information and video information, and shall display, but not be limited to, the following information: a) Unreceived information; b) Date and time information; c) Software version information; d) Receiving agent seat and receiving agent information; e) Offduty or onduty status information of receiving agents; f) Communication connection status information. Among the above information, the content in a) shall not be covered. 4.4 When two or more agent seats are online simultaneously receiving information, the software shall have functions for the assignment management of unreceived information to agent seats, for taking over information, and for transferring and pushing information. 4.5 During information processing, there shall be an indication of the receiving process. For improper operations, there shall be an alarm prompt. 4.6 The display interfaces for text information, geographic information and video information shall have associated operation functions. When processing newly received information on the text information display interface, the geographic information display interface and the video information display interface shall automatically switch to the corresponding geographic location and video interface. When performing a positioning operation on the geographic information display interface, the relevant location information shall be able to be extracted into the text information display interface. 4.7 The software shall be able to record and query the offduty and onduty times of receiving agents, the shift handover times of receiving agents, and duty notes, and shall have a log viewing function. The operation log shall include, but not be limited to, the start and exit times of the software, the times and content of parameter configuration changes, the times and content of software error prompts, and the times and status information of communication connection status changes. 4.8 The software shall have a time synchronisation function. The time deviation after time synchronisation shall comply with the provisions of GB/T 26875.1. 4.9 The software shall be able to receive, display, process and query the fire facility operational status information of networked units. 4.10 The software shall be able to display and query the fire safety management information of networked units, and shall be able to monitor and process the dynamic management information of the fire safety management information of networked units.
Contents of GB/T 26875.5-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 26875.5-2026, GB 26875.5-2026, GBT 26875.5-2026, GB/T26875.5-2026, GB/T 26875.5, GB/T26875.5, GB26875.5-2026, GB 26875.5, GB26875.5, GBT26875.5-2026, GBT 26875.5, GBT26875.5