2026-10-3 10.8.20.197
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 2985-2026
GB/T 2985-2026   Biological microscope (English)
Standard No.: GB/T 2985-2026 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):405.0 remind me the price change

Email:

Implemented on:2027-3-1 Delivery: via email in 1~5 business day

→ → →

,,2027-3-1,BB4562CA4BD3D8881788420223125
Standard No.: GB/T 2985-2026
English Name: Biological microscope
Chinese Name: 生物显微镜
Professional Classification: GB    National Standard
Source Content Issued by: SAMR, SAC
Issued on: 2026-08-28
Implemented on: 2027-3-1
Status: to be valid
Superseding:GB/T 2985-2008 Biological microscope
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 405.0
Delivery: via email in 1~5 business day
GB/T 2985-2026 Biological microscope English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 2985-2026 Biological microscope 生物显微镜 Issue date: 2026-06-27 Implementation date: 2027-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and basic parameters 5 Requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Bibliography Biological microscopes 1 Scope This document specifies the classification and basic parameters, requirements, inspection rules, marking, packaging, transportation and storage for biological microscope products, and describes the corresponding test methods. This document is applicable to various types of biological microscopes with a mechanical tube length of 160 mm or of the infinity type. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2828.1, Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 9247, Microscopes — Condensers GB/T 13384, General specifications for packaging of mechanical and electrical products GB/T 22055, Microscopes — Connecting dimensions of imaging components GB/T 22056, Microscopes — Marking of objectives and eyepieces GB/T 22059, Microscopes — Magnification values, tolerances and symbols GB/T 25480, Basic environmental conditions and test methods for transportation and storage of instruments and meters GB/T 27668, Microscopes — Terminology for light microscopy GB/T 42125.1, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 1: General requirements GB/T 43846.1, Microscopes — Designation of microscope objectives — Part 1: Flatness of field/plan GB/T 43846.2, Microscopes — Designation of microscope objectives — Part 2: Chromatic correction GB/T 43846.3, Microscopes — Designation of microscope objectives — Part 3: Spectral transmittance JB/T 7398.13, Microscopes — Test specimen slides for biological microscopes JB/T 8230.7, Microscopes — Dimensions and positions of holes for stage spring clips and mechanical stages 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 22055, GB/T 27668, GB/T 43846.1, GB/T 43846.2 and GB/T 43846.3, as well as the following, apply. 3.1 optical density (OD) A quantity representing the degree (ability) of light absorption by a substance. Note: Expressed by Formula (1): 4 Classification and basic parameters 4.1 The classification of biological microscopes (hereinafter referred to as "microscopes") is specified in Table 1. 4.2 The connecting dimensions of microscope imaging components shall comply with GB/T 22055. 4.3 The marking of microscope objectives and eyepieces shall comply with GB/T 22056. 4.4 The dimensions and positions of holes on the microscope stage for mounting the specimen mechanical stage or specimen clips (spring clips) shall comply with JB/T 8230.7. 5 Requirements 5.1 Optical and mechanical performance 5.1.1 The clear imaging range (diameter) of the microscope shall not be less than that specified in Table 2, with no phenomenon of one side being clear and the other side being blurred. 5.1.2 When different magnification objectives are interchanged using the objective nosepiece, the objectives shall be parfocal, and the parfocal deviation shall not exceed the range specified in Table 3. 5.1.3 The positioning of the objective nosepiece shall be accurate and stable, and its repeatability error shall meet the following requirements: a) Low-power popular microscope: ≤ 0.030 mm; b) High-power popular microscope: ≤ 0.025 mm; c) Laboratory microscope: ≤ 0.020 mm; d) Research microscope: ≤ 0.010 mm. 5.1.4 After interchanging different magnification objectives using the objective nosepiece, the following requirements shall be met: a) Popular microscope: The centre of the original image plane shall not move outside the field of view of the equipped eyepiece; b) Laboratory and research microscopes: The centre of the original image plane shall not move outside one-half of the field of view of the equipped eyepiece. 5.1.5 The connection between the stage and the microscope stand shall be firm. When a horizontal force of 5 N is applied to the left or right side of the stage, its maximum displacement shall not exceed 0.05 mm. After the force is removed, the stage shall return to its original position, and the deviation relative to the original position shall not exceed 0.005 mm. 5.1.6 When the specimen is moved within a 5 mm × 5 mm range using a movable stage or specimen mechanical stage, the specimen image shall be clear. If refocusing is required, the adjustment amount shall meet the following requirements: a) Popular microscope: ≤ 0.012 mm; b) Laboratory and research microscopes: ≤ 0.008 mm. 5.1.7 When using the fine focusing mechanism and observing with a 10× objective, the displacement of the image plane centre within the depth of field shall meet the following requirements: a) Popular microscope (high power): ≤ 0.1 mm; b) Laboratory and research microscopes: ≤ 0.05 mm. 5.1.8 The backlash of the fine focusing mechanism shall meet the following requirements: a) Popular microscope (low power): ≤ 0.016 mm; b) Popular microscope (high power): ≤ 0.008 mm; c) Laboratory microscope: ≤ 0.004 mm; d) Research microscope: ≤ 0.002 mm. 5.1.9 The magnification deviation of the microscope objective system shall not exceed ±5 %. 5.1.10 The magnification deviation of the microscope eyepiece shall not exceed ±5 %. 5.1.11 The optical axes of the illumination system and the observation system shall be aligned. The illumination in the field of view shall be uniform, with no phenomenon of one side being bright and the other side being dark, or of light blocking. When the condenser is raised to its highest position, the top of the condenser shall be 0.03 mm to 0.4 mm below the stage surface (not applicable to long working distance condensers). 5.1.12 When the microscope is equipped with a swing-out condenser, and the top lens swing frame is repeatedly swung into the optical path, the axis of the top lens shall be coaxial with the axis of the entire condenser, and the axis deviation in the focal plane of the condenser shall not exceed 0.02 mm.
Code of China
Standard
GB/T 2985-2026  Biological microscope (English)
Standard No.GB/T 2985-2026
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count13500 words
Translation Price(USD)405.0
Implemented on2027-3-1
Deliveryvia email in 1~5 business day
Detail of GB/T 2985-2026
Standard No.
GB/T 2985-2026
English Name
Biological microscope
Chinese Name
生物显微镜
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR, SAC
Issued on
2026-08-28
Implemented on
2027-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 2985-2008 Biological microscope
Language
English
File Format
PDF
Word Count
13500 words
Translation Price(USD)
405.0
Keywords
GB/T 2985-2026, GB 2985-2026, GBT 2985-2026, GB/T2985-2026, GB/T 2985, GB/T2985, GB2985-2026, GB 2985, GB2985, GBT2985-2026, GBT 2985, GBT2985
Introduction of GB/T 2985-2026
GB/T 2985-2026 Biological microscope English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered. ICS CCS National Standard of the People's Republic of China ‌GB/T 2985-2026 Biological microscope 生物显微镜 Issue date: 2026-06-27 Implementation date: 2027-05-01 Issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China the Standardization Administration of the People's Republic of China Contents Foreword Introduction 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and basic parameters 5 Requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Bibliography Biological microscopes 1 Scope This document specifies the classification and basic parameters, requirements, inspection rules, marking, packaging, transportation and storage for biological microscope products, and describes the corresponding test methods. This document is applicable to various types of biological microscopes with a mechanical tube length of 160 mm or of the infinity type. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB/T 2828.1, Sampling procedures for inspection by attributes — Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 9247, Microscopes — Condensers GB/T 13384, General specifications for packaging of mechanical and electrical products GB/T 22055, Microscopes — Connecting dimensions of imaging components GB/T 22056, Microscopes — Marking of objectives and eyepieces GB/T 22059, Microscopes — Magnification values, tolerances and symbols GB/T 25480, Basic environmental conditions and test methods for transportation and storage of instruments and meters GB/T 27668, Microscopes — Terminology for light microscopy GB/T 42125.1, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 1: General requirements GB/T 43846.1, Microscopes — Designation of microscope objectives — Part 1: Flatness of field/plan GB/T 43846.2, Microscopes — Designation of microscope objectives — Part 2: Chromatic correction GB/T 43846.3, Microscopes — Designation of microscope objectives — Part 3: Spectral transmittance JB/T 7398.13, Microscopes — Test specimen slides for biological microscopes JB/T 8230.7, Microscopes — Dimensions and positions of holes for stage spring clips and mechanical stages 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 22055, GB/T 27668, GB/T 43846.1, GB/T 43846.2 and GB/T 43846.3, as well as the following, apply. 3.1 optical density (OD) A quantity representing the degree (ability) of light absorption by a substance. Note: Expressed by Formula (1): 4 Classification and basic parameters 4.1 The classification of biological microscopes (hereinafter referred to as "microscopes") is specified in Table 1. 4.2 The connecting dimensions of microscope imaging components shall comply with GB/T 22055. 4.3 The marking of microscope objectives and eyepieces shall comply with GB/T 22056. 4.4 The dimensions and positions of holes on the microscope stage for mounting the specimen mechanical stage or specimen clips (spring clips) shall comply with JB/T 8230.7. 5 Requirements 5.1 Optical and mechanical performance 5.1.1 The clear imaging range (diameter) of the microscope shall not be less than that specified in Table 2, with no phenomenon of one side being clear and the other side being blurred. 5.1.2 When different magnification objectives are interchanged using the objective nosepiece, the objectives shall be parfocal, and the parfocal deviation shall not exceed the range specified in Table 3. 5.1.3 The positioning of the objective nosepiece shall be accurate and stable, and its repeatability error shall meet the following requirements: a) Low-power popular microscope: ≤ 0.030 mm; b) High-power popular microscope: ≤ 0.025 mm; c) Laboratory microscope: ≤ 0.020 mm; d) Research microscope: ≤ 0.010 mm. 5.1.4 After interchanging different magnification objectives using the objective nosepiece, the following requirements shall be met: a) Popular microscope: The centre of the original image plane shall not move outside the field of view of the equipped eyepiece; b) Laboratory and research microscopes: The centre of the original image plane shall not move outside one-half of the field of view of the equipped eyepiece. 5.1.5 The connection between the stage and the microscope stand shall be firm. When a horizontal force of 5 N is applied to the left or right side of the stage, its maximum displacement shall not exceed 0.05 mm. After the force is removed, the stage shall return to its original position, and the deviation relative to the original position shall not exceed 0.005 mm. 5.1.6 When the specimen is moved within a 5 mm × 5 mm range using a movable stage or specimen mechanical stage, the specimen image shall be clear. If refocusing is required, the adjustment amount shall meet the following requirements: a) Popular microscope: ≤ 0.012 mm; b) Laboratory and research microscopes: ≤ 0.008 mm. 5.1.7 When using the fine focusing mechanism and observing with a 10× objective, the displacement of the image plane centre within the depth of field shall meet the following requirements: a) Popular microscope (high power): ≤ 0.1 mm; b) Laboratory and research microscopes: ≤ 0.05 mm. 5.1.8 The backlash of the fine focusing mechanism shall meet the following requirements: a) Popular microscope (low power): ≤ 0.016 mm; b) Popular microscope (high power): ≤ 0.008 mm; c) Laboratory microscope: ≤ 0.004 mm; d) Research microscope: ≤ 0.002 mm. 5.1.9 The magnification deviation of the microscope objective system shall not exceed ±5 %. 5.1.10 The magnification deviation of the microscope eyepiece shall not exceed ±5 %. 5.1.11 The optical axes of the illumination system and the observation system shall be aligned. The illumination in the field of view shall be uniform, with no phenomenon of one side being bright and the other side being dark, or of light blocking. When the condenser is raised to its highest position, the top of the condenser shall be 0.03 mm to 0.4 mm below the stage surface (not applicable to long working distance condensers). 5.1.12 When the microscope is equipped with a swing-out condenser, and the top lens swing frame is repeatedly swung into the optical path, the axis of the top lens shall be coaxial with the axis of the entire condenser, and the axis deviation in the focal plane of the condenser shall not exceed 0.02 mm.
Contents of GB/T 2985-2026
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 2985-2026, GB 2985-2026, GBT 2985-2026, GB/T2985-2026, GB/T 2985, GB/T2985, GB2985-2026, GB 2985, GB2985, GBT2985-2026, GBT 2985, GBT2985