2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 35937-2018
GB/T 35937-2018   Household and similar drinking water purifier performance test method (English Version)
Standard No.: GB/T 35937-2018 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 1000 words Translation Price(USD):140.0 remind me the price change

Email:

Implemented on:2018-9-1 Delivery: via email in 1 business day

→ → →

,,2018-9-1,C966F8B7F6BE45C41519353860145
Standard No.: GB/T 35937-2018
English Name: Household and similar drinking water purifier performance test method
Chinese Name: 家用和类似用途饮用水处理装置性能测试方法
Chinese Classification: Y69    Others
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2018-02-06
Implemented on: 2018-9-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 1000 words
Translation Price(USD): 140.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by China National Light Industry Council. This standard is under the jurisdiction of the National Technical Committee on Household Electrical Appliances of Standardization Administration of China (SAC/TC 46). Household and Similar Drinking Water Purifier Performance Test Method 1 Scope This standard specifies the terms and definitions and test methods of household and similar drinking water purifier (hereinafter referred to as "water purifier"). This standard is applicable to the performance test of household and similar drinking water purifier. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 4706.1 Household and Similar Electrical Appliances - Safety Part 1: General Requirements GB 5749 Standards for Drinking Water Quality GB/T 5750 (All Parts) Standard Examination Methods for Drinking Water GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods GB/T 17218 Hygienic Safety Evaluation for Chemicals Used in Drinking Water Treatment GB/T 17219 Standard for Safety Evaluation of Equipment and Protective Materials in Drinking Water System GB/T 22090 Cold and Hot Water Dispenser 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 average influent challenge level the average concentration of certain substance led into water supply system during purification test 3.2 contaminant liquid the solution with specific concentration and containing one or several contaminant(s) during purification test 3.3 purification efficiency the ratio of purified volume by water purifier to contaminant liquid volume during purification test, expressed in % 3.4 concentrated water the general term for raw water treated by water purifier used for purposes other than domestic drinking water 4 Test Method 4.1 Test Conditions and Equipment 4.1.1 General test conditions Unless otherwise specified, the test shall be carried out under the following conditions: a) Ambient temperature: (25±5)℃; b) Test water temperature: (25±1)℃; c) Inlet pressure: (0.24±0.02)MPa; d) Relative humidity: 45%~75%; e) Water hardness: <450mg/L; f) The nominal value of power supply voltage provided by the manufacturer shall be adopted; g) Test shall be carried out in the laboratory with adjustable temperature and free of external hot air flow and thermal radiation action; h) Water purifier is installed according to the relevant requirements of operation instructions provided by the manufacturer for washing or regeneration of water purifying unit. 4.1.2 Inflow water quality used for test 4.1.2.1 Water purifier: The water quality of water purifier shall meet the following conditions: ——pH: 7.5±0.5; ——turbidity: <1.0NTU; ——total dissolved solids (TDS): (200~500)mg/L; ——TOC: ≤1.0mg/L. 4.1.2.2 Water softener: The water quality of water softener shall meet the following conditions: ——hardness: (342±34.2)mg/L(calculated in CaCO3); ——iron: <0.1mg/L; ——pH: 7.5±0.5; ——TDS: (350~500)mg/L; ——turbidity: <1.0NTU; ——sodium: ≤85.5mg/L. 4.1.2.3 Others: Complying with the municipal tap water requirements in GB 5749 or other centralized water supply requirements. 4.1.3 Main measuring instruments and their requirements: See Table 1 for measuring instruments and their parameters.   Table 1 Measuring Instruments and Parameters Measuring instrument Parameter Thermometer Precision: ±0.3℃ Ammeter Accuracy: not lower than Grade 0.5 Voltmeter Accuracy: not lower than Grade 0.5 Noise meter Sound level meter of Type 1 or superior Surface vibration tester Frequency response range: (10~1000)Hz Relative sensitivity: not exceeding -10%~+20% Measuring cylinder Precision: not lower than 10mL Timer Accuracy: ±1s Pressure gauge Precision: 2% Extensometer Precision: ±0.01mm 4.2 Visual Inspection 4.2.1 Test conditions Test conditions for visual inspection shall meet the following requirements: a) Ambient temperature: (25±5)℃; b) Relative humidity: 45%~75%; c) Lighting conditions: 1000lux-1500lux; d) The uncorrected (corrected) visual acuity of inspection personnel is above 4.5; e) The inspection surface forms a 45° angle with human eyes; f) Test distance: 0.5m-0.8m. 4.2.2 Test items Test items shall cover the following aspects: a) Inspect the appearance of water purifier; b) Inspect the surface of exposed structural parts of water purifier; c) Inspect the coating surface of water purifier; d) Inspect the decorative coating of electroplated parts and the surface of plastic parts. 4.3 Structural Performance Test 4.3.1 Test instruments See Figure 1 for devices of circulating pressure test and hydrostatic pressure test. The structural performance test shall be carried out in enclosed and isolated environment to avoid personnel injury or property damage during the test.
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Test Method 4.1 Test Conditions and Equipment 4.2 Visual Inspection 4.3 Structural Performance Test 4.4 Sanitary Safety Test 4.5 Performance Test 4.6 Electrical Safety Annex A (Informative) Preparation of Contaminant Liquids
Referred in GB/T 35937-2018:
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*GB 5749-2022 Standards for drinking water quality
*GB/T 5750-2006 Standard examination methods for drinking water
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB/T 17218-1998 Hygienic safety evaluation for chemicals used in drinking water treatment
*GB/T 17219-1998 Standard for Safety Evaluation of Equipment and Protective Mater
*GB/T 22090-2008 Cold and hot water dispenser
Code of China
Standard
GB/T 35937-2018  Household and similar drinking water purifier performance test method (English Version)
Standard No.GB/T 35937-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count1000 words
Price(USD)140.0
Implemented on2018-9-1
Deliveryvia email in 1 business day
Detail of GB/T 35937-2018
Standard No.
GB/T 35937-2018
English Name
Household and similar drinking water purifier performance test method
Chinese Name
家用和类似用途饮用水处理装置性能测试方法
Chinese Classification
Y69
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2018-02-06
Implemented on
2018-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
1000 words
Price(USD)
140.0
Keywords
GB/T 35937-2018, GB 35937-2018, GBT 35937-2018, GB/T35937-2018, GB/T 35937, GB/T35937, GB35937-2018, GB 35937, GB35937, GBT35937-2018, GBT 35937, GBT35937
Introduction of GB/T 35937-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by China National Light Industry Council. This standard is under the jurisdiction of the National Technical Committee on Household Electrical Appliances of Standardization Administration of China (SAC/TC 46). Household and Similar Drinking Water Purifier Performance Test Method 1 Scope This standard specifies the terms and definitions and test methods of household and similar drinking water purifier (hereinafter referred to as "water purifier"). This standard is applicable to the performance test of household and similar drinking water purifier. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 4706.1 Household and Similar Electrical Appliances - Safety Part 1: General Requirements GB 5749 Standards for Drinking Water Quality GB/T 5750 (All Parts) Standard Examination Methods for Drinking Water GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods GB/T 17218 Hygienic Safety Evaluation for Chemicals Used in Drinking Water Treatment GB/T 17219 Standard for Safety Evaluation of Equipment and Protective Materials in Drinking Water System GB/T 22090 Cold and Hot Water Dispenser 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 average influent challenge level the average concentration of certain substance led into water supply system during purification test 3.2 contaminant liquid the solution with specific concentration and containing one or several contaminant(s) during purification test 3.3 purification efficiency the ratio of purified volume by water purifier to contaminant liquid volume during purification test, expressed in % 3.4 concentrated water the general term for raw water treated by water purifier used for purposes other than domestic drinking water 4 Test Method 4.1 Test Conditions and Equipment 4.1.1 General test conditions Unless otherwise specified, the test shall be carried out under the following conditions: a) Ambient temperature: (25±5)℃; b) Test water temperature: (25±1)℃; c) Inlet pressure: (0.24±0.02)MPa; d) Relative humidity: 45%~75%; e) Water hardness: <450mg/L; f) The nominal value of power supply voltage provided by the manufacturer shall be adopted; g) Test shall be carried out in the laboratory with adjustable temperature and free of external hot air flow and thermal radiation action; h) Water purifier is installed according to the relevant requirements of operation instructions provided by the manufacturer for washing or regeneration of water purifying unit. 4.1.2 Inflow water quality used for test 4.1.2.1 Water purifier: The water quality of water purifier shall meet the following conditions: ——pH: 7.5±0.5; ——turbidity: <1.0NTU; ——total dissolved solids (TDS): (200~500)mg/L; ——TOC: ≤1.0mg/L. 4.1.2.2 Water softener: The water quality of water softener shall meet the following conditions: ——hardness: (342±34.2)mg/L(calculated in CaCO3); ——iron: <0.1mg/L; ——pH: 7.5±0.5; ——TDS: (350~500)mg/L; ——turbidity: <1.0NTU; ——sodium: ≤85.5mg/L. 4.1.2.3 Others: Complying with the municipal tap water requirements in GB 5749 or other centralized water supply requirements. 4.1.3 Main measuring instruments and their requirements: See Table 1 for measuring instruments and their parameters.   Table 1 Measuring Instruments and Parameters Measuring instrument Parameter Thermometer Precision: ±0.3℃ Ammeter Accuracy: not lower than Grade 0.5 Voltmeter Accuracy: not lower than Grade 0.5 Noise meter Sound level meter of Type 1 or superior Surface vibration tester Frequency response range: (10~1000)Hz Relative sensitivity: not exceeding -10%~+20% Measuring cylinder Precision: not lower than 10mL Timer Accuracy: ±1s Pressure gauge Precision: 2% Extensometer Precision: ±0.01mm 4.2 Visual Inspection 4.2.1 Test conditions Test conditions for visual inspection shall meet the following requirements: a) Ambient temperature: (25±5)℃; b) Relative humidity: 45%~75%; c) Lighting conditions: 1000lux-1500lux; d) The uncorrected (corrected) visual acuity of inspection personnel is above 4.5; e) The inspection surface forms a 45° angle with human eyes; f) Test distance: 0.5m-0.8m. 4.2.2 Test items Test items shall cover the following aspects: a) Inspect the appearance of water purifier; b) Inspect the surface of exposed structural parts of water purifier; c) Inspect the coating surface of water purifier; d) Inspect the decorative coating of electroplated parts and the surface of plastic parts. 4.3 Structural Performance Test 4.3.1 Test instruments See Figure 1 for devices of circulating pressure test and hydrostatic pressure test. The structural performance test shall be carried out in enclosed and isolated environment to avoid personnel injury or property damage during the test.
Contents of GB/T 35937-2018
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Test Method 4.1 Test Conditions and Equipment 4.2 Visual Inspection 4.3 Structural Performance Test 4.4 Sanitary Safety Test 4.5 Performance Test 4.6 Electrical Safety Annex A (Informative) Preparation of Contaminant Liquids
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 35937-2018, GB 35937-2018, GBT 35937-2018, GB/T35937-2018, GB/T 35937, GB/T35937, GB35937-2018, GB 35937, GB35937, GBT35937-2018, GBT 35937, GBT35937