2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 41336-2022
GB/T 41336-2022   Classification and test method for fire resistant performance of curtain wall (English Version)
Standard No.: GB/T 41336-2022 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):255.0 remind me the price change

Email:

Implemented on:2022-10-1 Delivery: via email in 1~3 business day

→ → →

,,2022-10-1,913D0AD7652582E41647924862829
Standard No.: GB/T 41336-2022
English Name: Classification and test method for fire resistant performance of curtain wall
Chinese Name: 建筑幕墙防火性能分级及试验方法
Chinese Classification: P32    Building construction and decoration engineering
Professional Classification: GB    National Standard
ICS Classification: 91.060.10 91.060.10    Walls. Partitions. Fa?ades 91.060.10
Source Content Issued by: SAMR; SAC
Issued on: 2022-03-09
Implemented on: 2022-10-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 255.0
Delivery: via email in 1~3 business day
Classification and test method for fire resistant performance of curtain wall Warning: All personnel carrying out this test shall be aware that this test may cause personal injuries. During the test, toxic or harmful smoke dust and fume may be produced. Mechanical injuries and operational hazards may occur during test piece installation, during the test and during the cleaning of test pieces after the test. Before the test, all potential hazards and health hazards shall be analyzed and safety forecasts shall be made. Necessary training shall be provided for relevant personnel. Laboratory staff shall operate in strict accordance with safety operation procedures and take reliable protective measures. 1 Scope This document specifies the classification for fire resistant performance of curtain wall, test apparatus and instruments, test conditions, test piece requirements, test piece installation and test zones, measuring instrument layout, test procedures, test results and judgments, and the test report. This document is applicable to the classification for fire resistant performance of fire-resistant construction of curtain wall (including fire-resistant curtain wall, fire-resistant curtain wall outside spandrel area, firestopping between floor and curtain wall and firestopping between firewall and curtain wall). 2 Normative references The following documents contain requirements which, through reference in this text, constitute indispensable requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 5907.1 Fire protection vocabulary - Part 1: General terms GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 12513 Fire-resistance tests - Elements of building construction - Glazed elements GB/T 26784 Fire resistance test for elements of building construction - Alternative and additional procedures GB/T 34327 Terminology for curtain wall   3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5907.1 and GB/T 34327 and the following apply. 3.1 fire-resistant construction of curtain wall joint protection and perimeter fire barriers which are located at inter-floor slab and firewall between floor and curtain wall, with a certain fire-resistant performance and able to block flame, smoke spread or heat transfer 3.2 fire-resistant performance of curtain wall ability of a fire-resistant construction of curtain wall to meet the requirements of fire-resistant integrity, fire-resistant heat insulation or reduction of radiation under standard test conditions 3.3 fire-resistant curtain wall curtain wall construction located at the opening of the external wall of a building and used to prevent the spread of internal and external fire spread 3.4 fire-resistant curtain wall outside spandrel area construction located between the upper and lower floor openings of the external wall of a building and used to prevent the spread of internal and external fire spread 3.5 firestopping between floor and curtain wall blocking and sealing system located between inter-floor solid wall or slab and fire-resistant curtain wall outside spandrel area or fire-resistant curtain wall of a building, which has the functions of sealing and expansion deformation under normal use conditions and prevents the internal fire spread in the vertical direction in case of fire 3.6 firestopping between firewall and curtain wall blocking and sealing system located between firewall and fire-resistant curtain wall of a building, which has the functions of sealing and expansion deformation under normal use conditions and prevents the internal fire spread in the horizontal direction in case of fire 3.7 reduction of radiation ability of fire-resistant construction of curtain wall to prevent heat radiation under standard test conditions 3.8 internal fire exposure curve standard curve used to simulate the temperature-time relationship in an internal fire of a building 3.9 external fire exposure curve standard curve used to simulate temperature-time relationship in an external fire of a building 3.10 assistant fire- resistant member member which meets the actual requirements for fire resistance rating of engineering, allows the installation and connection of test pieces, and has the functions of a closed test furnace 3.11 furnace closure member combined member which is composed of supporting frame and/or heat insulation material and has the functions of a closed test furnace 3.12 movement capability ability of firestopping between floor and curtain wall or firestopping between firewall and curtain wall to adapt to displacement change under the action of reciprocating load in the width direction of blocked joint
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Classification of fire resistance performance 5 Test apparatus and instruments 6 Test conditions 7 Requirements for test pieces 8 Test piece installation and test zones 9 Measuring instrument layout 10 Test procedures 11 Test results and judgement 12 Test report
Code of China
Standard
GB/T 41336-2022  Classification and test method for fire resistant performance of curtain wall (English Version)
Standard No.GB/T 41336-2022
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)255.0
Implemented on2022-10-1
Deliveryvia email in 1~3 business day
Detail of GB/T 41336-2022
Standard No.
GB/T 41336-2022
English Name
Classification and test method for fire resistant performance of curtain wall
Chinese Name
建筑幕墙防火性能分级及试验方法
Chinese Classification
P32
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2022-03-09
Implemented on
2022-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
255.0
Keywords
GB/T 41336-2022, GB 41336-2022, GBT 41336-2022, GB/T41336-2022, GB/T 41336, GB/T41336, GB41336-2022, GB 41336, GB41336, GBT41336-2022, GBT 41336, GBT41336
Introduction of GB/T 41336-2022
Classification and test method for fire resistant performance of curtain wall Warning: All personnel carrying out this test shall be aware that this test may cause personal injuries. During the test, toxic or harmful smoke dust and fume may be produced. Mechanical injuries and operational hazards may occur during test piece installation, during the test and during the cleaning of test pieces after the test. Before the test, all potential hazards and health hazards shall be analyzed and safety forecasts shall be made. Necessary training shall be provided for relevant personnel. Laboratory staff shall operate in strict accordance with safety operation procedures and take reliable protective measures. 1 Scope This document specifies the classification for fire resistant performance of curtain wall, test apparatus and instruments, test conditions, test piece requirements, test piece installation and test zones, measuring instrument layout, test procedures, test results and judgments, and the test report. This document is applicable to the classification for fire resistant performance of fire-resistant construction of curtain wall (including fire-resistant curtain wall, fire-resistant curtain wall outside spandrel area, firestopping between floor and curtain wall and firestopping between firewall and curtain wall). 2 Normative references The following documents contain requirements which, through reference in this text, constitute indispensable requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 5907.1 Fire protection vocabulary - Part 1: General terms GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 12513 Fire-resistance tests - Elements of building construction - Glazed elements GB/T 26784 Fire resistance test for elements of building construction - Alternative and additional procedures GB/T 34327 Terminology for curtain wall   3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5907.1 and GB/T 34327 and the following apply. 3.1 fire-resistant construction of curtain wall joint protection and perimeter fire barriers which are located at inter-floor slab and firewall between floor and curtain wall, with a certain fire-resistant performance and able to block flame, smoke spread or heat transfer 3.2 fire-resistant performance of curtain wall ability of a fire-resistant construction of curtain wall to meet the requirements of fire-resistant integrity, fire-resistant heat insulation or reduction of radiation under standard test conditions 3.3 fire-resistant curtain wall curtain wall construction located at the opening of the external wall of a building and used to prevent the spread of internal and external fire spread 3.4 fire-resistant curtain wall outside spandrel area construction located between the upper and lower floor openings of the external wall of a building and used to prevent the spread of internal and external fire spread 3.5 firestopping between floor and curtain wall blocking and sealing system located between inter-floor solid wall or slab and fire-resistant curtain wall outside spandrel area or fire-resistant curtain wall of a building, which has the functions of sealing and expansion deformation under normal use conditions and prevents the internal fire spread in the vertical direction in case of fire 3.6 firestopping between firewall and curtain wall blocking and sealing system located between firewall and fire-resistant curtain wall of a building, which has the functions of sealing and expansion deformation under normal use conditions and prevents the internal fire spread in the horizontal direction in case of fire 3.7 reduction of radiation ability of fire-resistant construction of curtain wall to prevent heat radiation under standard test conditions 3.8 internal fire exposure curve standard curve used to simulate the temperature-time relationship in an internal fire of a building 3.9 external fire exposure curve standard curve used to simulate temperature-time relationship in an external fire of a building 3.10 assistant fire- resistant member member which meets the actual requirements for fire resistance rating of engineering, allows the installation and connection of test pieces, and has the functions of a closed test furnace 3.11 furnace closure member combined member which is composed of supporting frame and/or heat insulation material and has the functions of a closed test furnace 3.12 movement capability ability of firestopping between floor and curtain wall or firestopping between firewall and curtain wall to adapt to displacement change under the action of reciprocating load in the width direction of blocked joint
Contents of GB/T 41336-2022
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Classification of fire resistance performance 5 Test apparatus and instruments 6 Test conditions 7 Requirements for test pieces 8 Test piece installation and test zones 9 Measuring instrument layout 10 Test procedures 11 Test results and judgement 12 Test report
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 41336-2022, GB 41336-2022, GBT 41336-2022, GB/T41336-2022, GB/T 41336, GB/T41336, GB41336-2022, GB 41336, GB41336, GBT41336-2022, GBT 41336, GBT41336