2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 43080.3-2023
GB/T 43080.3-2023   Fans—Efficiency classification for fans—Part 3: Fans without drives at maximum operating speed (English Version)
Standard No.: GB/T 43080.3-2023 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):240.0 remind me the price change

Email:

Implemented on:2024-4-1 Delivery: via email in 1 business day

→ → →

,,2024-4-1,2BCD1842A5FFE30D1695043745660
Standard No.: GB/T 43080.3-2023
English Name: Fans—Efficiency classification for fans—Part 3: Fans without drives at maximum operating speed
Chinese Name: 通风机 通风机效率等级 第3部分:不含驱动装置最高转速时的通风机
Chinese Classification: J72    Compressor and fan
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2023-9-7
Implemented on: 2024-4-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 240.0
Delivery: via email in 1 business day
GB/T 43080.3-2023 Ion conductive membrane for Vanadium flow battery - Technical conditions and test methods 1 Scope This document specifies the terms and definitions, sampling methods and general conditions, technical requirements, and test methods for the thickness uniformity, areal resistance, conductivity, ion exchange capacity, tensile properties, water uptake, dimensional change rate, vanadium ion diffusion coefficient, ion permeation selectivity and oxidation resistance of ion conductive membrane for vanadium flow battery. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 601-2016 Chemical reagent - Preparations of reference titration solutions GB/T 1040.3-2006 Plastics - Determination of tensile properties - Part 3: Test conditions for films and sheets GB/T 1462-2005 Test methods for water absorption of fiber reinforced plastics GB/T 6672-2001 Plastics film and sheeting - Determination of thickness by mechanical scanning GB/T 20042.3 Proton exchange membrane fuel cell - Part 3: Test method for proton exchange membrane GB/T 20103 Technical terms for membrane separation GB/T 29840-2013 Vanadium flow battery - Terminology 3 Terms and definitions For the purpose of this document, the terms and definitions given in GB/T 29840-2013 and GB/T 20042.3 and the following apply. 3.1 ion conductive membrane membrane that separates the positive and negative electrolytes and selectively conducts ions [Source: GB/T 29840-2013, 2.2, modified] Note: Both ion exchange membranes and porous ion conductive membranes belong to ion conductive membranes, and their mechanisms of conducting ions are the ion exchange mechanism and sieving mechanism respectively. 3.2 ion exchange membrane ion conductive membrane containing ion exchange groups, which may selectively permeate ions 3.3 porous ion conductive membrane ion conductive membrane for sieving and conducting hydrogen ions and vanadium ions by nano-aperture 3.4 membrane resistance resistance in the membrane thickness direction at given temperature and solution composition, expressed in Ω 3.5 effective area geometric area of an ion conductive membrane realizing ion conduction, perpendicular to the current direction, expressed in cm2 3.6 membrane area resistance product of the resistance and the effective area of the ion conductive membrane during measurement, expressed in Ω·cm2 3.7 membrane conductivity capability of a membrane to pass ions, which is equal to the ratio of membrane thickness to membrane area resistance, expressed in S/cm 3.8 dry membrane membrane containing no free water within as opposed to wet membrane Note: It is typically obtained by drying an ion conductive membrane in an oven at 105℃~110℃ for a certain period of time until it reaches a constant weight as weighed by a balance. 3.9 ion exchange capacity (IEC) number of moles of ion exchange groups per gram of dry ion exchange membrane, expressed in mol/g 3.10 water uptake rate of mass change of a dry membrane before and after water absorption at a specified temperature and humidity, expressed in percentage (%) 3.11 dimensional change rate dimensional change rate in the transverse, machine and thickness directions of a membrane after being immersed in a specific solvent for a certain time at a specified temperature and humidity, expressed in percentage (%) 3.12 ion diffusion coefficient quantity of ions permeating through an ion conductive membrane under given conditions, expressed in cm2/s 3.13 ion permeation selectivity capability of an ion conductive membrane to selectively allow permeation of different ions, quantified as the ratio of ion diffusion coefficients for different ions measured under given conditions 4 Technical requirements 4.1 General In a vanadium battery, the ion conductive membrane divides the battery into two half-cells, separating the electrolytes at the cathode and the anode, and forming a current loop by transferring ions. An ideal ion conductive membrane shall have the following properties: ——Low dimensional change rate; ——High membrane conductivity and ion permeation selectivity; ——Low vanadium ion diffusion coefficient; ——Robust chemical stability. 4.2 Indicator requirements The technical indicators of ion conductive membrane shall be as specified in Table 1.
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Technical requirements 4.1 General 4.2 Indicator requirements 5 Test methods 5.1 Sampling method and general conditions 5.2 Accuracy requirements for instruments 5.3 Thickness uniformity 5.4 Water uptake 5.5 Dimensional change rate 5.6 Tensile properties 5.7 Conductivity and membrane area resistance 5.8 Ion exchange capacity (IEC) 5.9 Vanadium ion diffusion properties 5.10 Ion permeation selectivity 5.11 Oxidation resistance Annex A (Normative) Pretreatment method for ion conductive membrane Annex B (Normative) Calibration of 0.1mol/L NaOH standard solution Annex C (Informative) Preparation method before ion permeation selectivity coefficient test Annex D (Informative) Derivation method for equation for ion diffusion coefficient
Referred in GB/T 43080.3-2023:
*GB/T 601-2016 Chemical Reagent - Preparations of Standard Volumetric Solutions
*GB/T 1040.3-2006 Plastics - Determination of Tensile Properties - Part 3: Test Conditions for Films and Sheets
*GB/T 1462-2005 Test methods for water absorption of fiber reinforced plastics
*GB/T 6672-2001 Plastics film and sheeting--Determination of thickness by mechanical scanning
*GB/T 20042.3-2022 Proton exchange membrane fuel cell—Part 3: Test method for proton exchange membrane
*GB/T 20103-2006 Technical terms for membrane separation
*GB/T 29840-2013 Vanadium flow battery—Terminology
Code of China
Standard
GB/T 43080.3-2023  Fans—Efficiency classification for fans—Part 3: Fans without drives at maximum operating speed (English Version)
Standard No.GB/T 43080.3-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)240.0
Implemented on2024-4-1
Deliveryvia email in 1 business day
Detail of GB/T 43080.3-2023
Standard No.
GB/T 43080.3-2023
English Name
Fans—Efficiency classification for fans—Part 3: Fans without drives at maximum operating speed
Chinese Name
通风机 通风机效率等级 第3部分:不含驱动装置最高转速时的通风机
Chinese Classification
J72
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2023-9-7
Implemented on
2024-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
240.0
Keywords
GB/T 43080.3-2023, GB 43080.3-2023, GBT 43080.3-2023, GB/T43080.3-2023, GB/T 43080.3, GB/T43080.3, GB43080.3-2023, GB 43080.3, GB43080.3, GBT43080.3-2023, GBT 43080.3, GBT43080.3
Introduction of GB/T 43080.3-2023
GB/T 43080.3-2023 Ion conductive membrane for Vanadium flow battery - Technical conditions and test methods 1 Scope This document specifies the terms and definitions, sampling methods and general conditions, technical requirements, and test methods for the thickness uniformity, areal resistance, conductivity, ion exchange capacity, tensile properties, water uptake, dimensional change rate, vanadium ion diffusion coefficient, ion permeation selectivity and oxidation resistance of ion conductive membrane for vanadium flow battery. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 601-2016 Chemical reagent - Preparations of reference titration solutions GB/T 1040.3-2006 Plastics - Determination of tensile properties - Part 3: Test conditions for films and sheets GB/T 1462-2005 Test methods for water absorption of fiber reinforced plastics GB/T 6672-2001 Plastics film and sheeting - Determination of thickness by mechanical scanning GB/T 20042.3 Proton exchange membrane fuel cell - Part 3: Test method for proton exchange membrane GB/T 20103 Technical terms for membrane separation GB/T 29840-2013 Vanadium flow battery - Terminology 3 Terms and definitions For the purpose of this document, the terms and definitions given in GB/T 29840-2013 and GB/T 20042.3 and the following apply. 3.1 ion conductive membrane membrane that separates the positive and negative electrolytes and selectively conducts ions [Source: GB/T 29840-2013, 2.2, modified] Note: Both ion exchange membranes and porous ion conductive membranes belong to ion conductive membranes, and their mechanisms of conducting ions are the ion exchange mechanism and sieving mechanism respectively. 3.2 ion exchange membrane ion conductive membrane containing ion exchange groups, which may selectively permeate ions 3.3 porous ion conductive membrane ion conductive membrane for sieving and conducting hydrogen ions and vanadium ions by nano-aperture 3.4 membrane resistance resistance in the membrane thickness direction at given temperature and solution composition, expressed in Ω 3.5 effective area geometric area of an ion conductive membrane realizing ion conduction, perpendicular to the current direction, expressed in cm2 3.6 membrane area resistance product of the resistance and the effective area of the ion conductive membrane during measurement, expressed in Ω·cm2 3.7 membrane conductivity capability of a membrane to pass ions, which is equal to the ratio of membrane thickness to membrane area resistance, expressed in S/cm 3.8 dry membrane membrane containing no free water within as opposed to wet membrane Note: It is typically obtained by drying an ion conductive membrane in an oven at 105℃~110℃ for a certain period of time until it reaches a constant weight as weighed by a balance. 3.9 ion exchange capacity (IEC) number of moles of ion exchange groups per gram of dry ion exchange membrane, expressed in mol/g 3.10 water uptake rate of mass change of a dry membrane before and after water absorption at a specified temperature and humidity, expressed in percentage (%) 3.11 dimensional change rate dimensional change rate in the transverse, machine and thickness directions of a membrane after being immersed in a specific solvent for a certain time at a specified temperature and humidity, expressed in percentage (%) 3.12 ion diffusion coefficient quantity of ions permeating through an ion conductive membrane under given conditions, expressed in cm2/s 3.13 ion permeation selectivity capability of an ion conductive membrane to selectively allow permeation of different ions, quantified as the ratio of ion diffusion coefficients for different ions measured under given conditions 4 Technical requirements 4.1 General In a vanadium battery, the ion conductive membrane divides the battery into two half-cells, separating the electrolytes at the cathode and the anode, and forming a current loop by transferring ions. An ideal ion conductive membrane shall have the following properties: ——Low dimensional change rate; ——High membrane conductivity and ion permeation selectivity; ——Low vanadium ion diffusion coefficient; ——Robust chemical stability. 4.2 Indicator requirements The technical indicators of ion conductive membrane shall be as specified in Table 1.
Contents of GB/T 43080.3-2023
Foreword II 1 Scope 2 Normative references 3 Terms and definitions 4 Technical requirements 4.1 General 4.2 Indicator requirements 5 Test methods 5.1 Sampling method and general conditions 5.2 Accuracy requirements for instruments 5.3 Thickness uniformity 5.4 Water uptake 5.5 Dimensional change rate 5.6 Tensile properties 5.7 Conductivity and membrane area resistance 5.8 Ion exchange capacity (IEC) 5.9 Vanadium ion diffusion properties 5.10 Ion permeation selectivity 5.11 Oxidation resistance Annex A (Normative) Pretreatment method for ion conductive membrane Annex B (Normative) Calibration of 0.1mol/L NaOH standard solution Annex C (Informative) Preparation method before ion permeation selectivity coefficient test Annex D (Informative) Derivation method for equation for ion diffusion coefficient
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 43080.3-2023, GB 43080.3-2023, GBT 43080.3-2023, GB/T43080.3-2023, GB/T 43080.3, GB/T43080.3, GB43080.3-2023, GB 43080.3, GB43080.3, GBT43080.3-2023, GBT 43080.3, GBT43080.3