2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 46261-2025
GB/T 46261-2025   General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations (English Version)
Standard No.: GB/T 46261-2025 Status:to be valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 36000 words Translation Price(USD):1080.0 remind me the price change

Email:

Implemented on:2026-9-1 Delivery: via email in 1~10 business day

→ → →

,,2026-9-1,6631846A0C16AD241756977119202
Standard No.: GB/T 46261-2025
English Name: General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations
Chinese Name: 电化学储能电站火灾监测预警系统通用技术要求
Chinese Classification: C81    Fire monitoring, alarming and fire-fighting dispatching system
Professional Classification: GB    National Standard
ICS Classification: 13.220.20 13.220.20    Fire protection 13.220.20
Source Content Issued by: SAMR; SAC
Issued on: 2025-8-29
Implemented on: 2026-9-1
Status: to be valid
Target Language: English
File Format: PDF
Word Count: 36000 words
Translation Price(USD): 1080.0
Delivery: via email in 1~10 business day
GB/T 46261-2025 General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing thorugh draft translation, self-check, revision and varification) will be delivered upon being ordered. ICS 13.220.20 CCS C 81 National Standard of the People's Republic of China GB/T 46261-2025 General Technical Requirements for Fire Monitoring and Warning Systems in Electrochemical Energy Storage Stations Issued on : 2025-08-29 Implementation on : 2026-09-01 Issued by: State Administration for Market Regulation, Standardization Administration of China Contents Preface 1 Scope 2 Normative References 3 Terms and definitions 4 Models and Categories 5 Requirements 6 experiments 7 Inspection Rules 8 Signs and packaging Appendix A (Informative) Systems and Equipment Appendix B (Normative) Product Models Appendix C (Normative) Compatibility Requirements Appendix D (Normative) Combustion Performance of Control Device Shell Appendix E (Normative) Control Device Operation Data Storage Unit Appendix F (Normative) Threshold Inspection Smoke Box Appendix G (Normative) Battery Thermal runaway Alarm Performance Test Equipment and Test Methods Appendix H (Normative) Electrolyte Fire Sensitivity Test Equipment and Test Methods Appendix I (Normative) Gas Testing Equipment and Test Methods Appendix J (Normative) Standard Temperature Chamber Appendix K (Normative) Pressure Monitoring Performance Test Device 1 Scope This document defines terms for fire monitoring and warning systems in electrochemical energy storage stations (ESS), specifies classification, requirements, inspection rules, and labeling, and describes corresponding test methods. Applicability: Design, manufacture, and inspection of fire monitoring and warning system equipment installed in ESS and energy storage devices. 2 Normative References GB/T 4208—2017 Degrees of protection provided by enclosures (IP Code) GB 4717—2024 Fire alarm control units GB/T 5907.5 Fire protection vocabulary - Part 5: Fire protection products GB/T 17626 series Electromagnetic compatibility testing standards 3 Terms and Definitions 3. 1 Fire monitoring and warning systems for electrochemical energy storage stations A system for fire monitoring, warning, and equipment linkage control in electrochemical energy storage power plants. Note: The system equipment includes fire alarm control devices for electrochemical energy storage power stations, various fire monitoring and alarm devices for electrochemical energy storage power stations, fire detectors and other fire alarm triggering devices, combustible gas detectors, manual fire alarm buttons, modules, fire sound and light alarms, gas release alarms, etc. The system composition and equipment are detailed in Appendix A. three point two Fire alarm control units for electrochemical energy storage power plants- tions A device installed in an electrochemical energy storage power station that can receive thermal runaway warning signals, thermal runaway fire monitoring alarm signals, and fault signals from the fire monitoring and alarm device and other alarm triggering devices of the electrochemical energy storage power station, and complete status display and linkage control functions. three point three Fire detectors for electrochemical energy storage stations A device installed in an electrochemical energy storage power station that uses one or more sensors to continuously monitor various physical and/or chemical phenomena during the initial stage of thermal runaway in battery cells, battery modules, battery packs, etc., and outputs thermal runaway warning or thermal runaway fire monitoring alarm signals to the control device. 4 Models and Categories 4.1 Model The model designation method for the fire alarm control device (hereinafter referred to as the "control device") and the fire monitoring and alarm device (hereinafter referred to as the "monitoring and alarm device") of the electrochemical energy storage power station shall meet the requirements of Appendix B. 4.2 Classification of Control Devices Divided by application method: Type I: Independent monitoring and alarm control device; - Type II: Independent control device; - Type III: Regional control device; - Type IV: Centralized control device; - Type V: Centralized area compatible control device. 4.3 Classification of Monitoring and Alarm Devices 4.3. 1. Divided by sensor type: YJA type: gas monitoring and warning device for electrochemical energy storage power plants; JCA type: Electrochemical energy storage power plant carbon monoxide and smoke and temperature sensing composite fire monitoring and alarm device; JCB type: Electrochemical energy storage power plant hydrogen and smoke and temperature sensing composite fire monitoring and alarm device; JCC type: Electrochemical energy storage power plant hydrogen, carbon monoxide, and smoke and temperature sensing composite fire monitoring and alarm device; JCD type: Electrochemical energy storage power plant carbon dioxide and smoke and temperature sensing composite fire monitoring and alarm device; JCE type: Electrochemical energy storage power plant hydrogen, carbon dioxide, and smoke and temperature sensing composite fire monitoring and alarm device; JCF type: Electrochemical energy storage power station suction type carbon monoxide and smoke sensing composite gas monitoring and alarm device; JCG type: Electrochemical energy storage power station suction type hydrogen, carbon monoxide, and smoke sensing composite gas monitoring and alarm device; JCH type: Electrochemical energy storage power station suction type carbon dioxide and smoke sensing composite gas monitoring and alarm device; JCI type: Electrochemical energy storage power station suction type hydrogen, carbon dioxide, and smoke sensing composite gas monitoring and alarm device. 4.3.2 Classified according to applicable electrochemical energy storage power stations: - Air cooled type: suitable for monitoring and alarm devices in air-cooled electrochemical energy storage power plants; Liquid cooled type: suitable for monitoring and alarm devices in liquid cooled electrochemical energy storage power plants. 4.3.3 Divided by applicable environment: - Ordinary type: suitable for electrochemical energy storage power plants with ambient temperatures ranging from -10 ℃ to 55 ℃; Special type: suitable for electrochemical energy storage power plants with ambient temperatures ranging from -40 ℃ to 70 ℃.
Code of China
Standard
GB/T 46261-2025  General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations (English Version)
Standard No.GB/T 46261-2025
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count36000 words
Price(USD)1080.0
Implemented on2026-9-1
Deliveryvia email in 1~10 business day
Detail of GB/T 46261-2025
Standard No.
GB/T 46261-2025
English Name
General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations
Chinese Name
电化学储能电站火灾监测预警系统通用技术要求
Chinese Classification
C81
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-8-29
Implemented on
2026-9-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
36000 words
Price(USD)
1080.0
Keywords
GB/T 46261-2025, GB 46261-2025, GBT 46261-2025, GB/T46261-2025, GB/T 46261, GB/T46261, GB46261-2025, GB 46261, GB46261, GBT46261-2025, GBT 46261, GBT46261
Introduction of GB/T 46261-2025
GB/T 46261-2025 General technical requirements for fire monitoring and warning systems for electrochemical energy storage stations English, Anglais, Englisch, Inglés, えいご This is a draft translation for reference among interesting stakeholders. The finalized translation (passing thorugh draft translation, self-check, revision and varification) will be delivered upon being ordered. ICS 13.220.20 CCS C 81 National Standard of the People's Republic of China GB/T 46261-2025 General Technical Requirements for Fire Monitoring and Warning Systems in Electrochemical Energy Storage Stations Issued on : 2025-08-29 Implementation on : 2026-09-01 Issued by: State Administration for Market Regulation, Standardization Administration of China Contents Preface 1 Scope 2 Normative References 3 Terms and definitions 4 Models and Categories 5 Requirements 6 experiments 7 Inspection Rules 8 Signs and packaging Appendix A (Informative) Systems and Equipment Appendix B (Normative) Product Models Appendix C (Normative) Compatibility Requirements Appendix D (Normative) Combustion Performance of Control Device Shell Appendix E (Normative) Control Device Operation Data Storage Unit Appendix F (Normative) Threshold Inspection Smoke Box Appendix G (Normative) Battery Thermal runaway Alarm Performance Test Equipment and Test Methods Appendix H (Normative) Electrolyte Fire Sensitivity Test Equipment and Test Methods Appendix I (Normative) Gas Testing Equipment and Test Methods Appendix J (Normative) Standard Temperature Chamber Appendix K (Normative) Pressure Monitoring Performance Test Device 1 Scope This document defines terms for fire monitoring and warning systems in electrochemical energy storage stations (ESS), specifies classification, requirements, inspection rules, and labeling, and describes corresponding test methods. Applicability: Design, manufacture, and inspection of fire monitoring and warning system equipment installed in ESS and energy storage devices. 2 Normative References GB/T 4208—2017 Degrees of protection provided by enclosures (IP Code) GB 4717—2024 Fire alarm control units GB/T 5907.5 Fire protection vocabulary - Part 5: Fire protection products GB/T 17626 series Electromagnetic compatibility testing standards 3 Terms and Definitions 3. 1 Fire monitoring and warning systems for electrochemical energy storage stations A system for fire monitoring, warning, and equipment linkage control in electrochemical energy storage power plants. Note: The system equipment includes fire alarm control devices for electrochemical energy storage power stations, various fire monitoring and alarm devices for electrochemical energy storage power stations, fire detectors and other fire alarm triggering devices, combustible gas detectors, manual fire alarm buttons, modules, fire sound and light alarms, gas release alarms, etc. The system composition and equipment are detailed in Appendix A. three point two Fire alarm control units for electrochemical energy storage power plants- tions A device installed in an electrochemical energy storage power station that can receive thermal runaway warning signals, thermal runaway fire monitoring alarm signals, and fault signals from the fire monitoring and alarm device and other alarm triggering devices of the electrochemical energy storage power station, and complete status display and linkage control functions. three point three Fire detectors for electrochemical energy storage stations A device installed in an electrochemical energy storage power station that uses one or more sensors to continuously monitor various physical and/or chemical phenomena during the initial stage of thermal runaway in battery cells, battery modules, battery packs, etc., and outputs thermal runaway warning or thermal runaway fire monitoring alarm signals to the control device. 4 Models and Categories 4.1 Model The model designation method for the fire alarm control device (hereinafter referred to as the "control device") and the fire monitoring and alarm device (hereinafter referred to as the "monitoring and alarm device") of the electrochemical energy storage power station shall meet the requirements of Appendix B. 4.2 Classification of Control Devices Divided by application method: Type I: Independent monitoring and alarm control device; - Type II: Independent control device; - Type III: Regional control device; - Type IV: Centralized control device; - Type V: Centralized area compatible control device. 4.3 Classification of Monitoring and Alarm Devices 4.3. 1. Divided by sensor type: YJA type: gas monitoring and warning device for electrochemical energy storage power plants; JCA type: Electrochemical energy storage power plant carbon monoxide and smoke and temperature sensing composite fire monitoring and alarm device; JCB type: Electrochemical energy storage power plant hydrogen and smoke and temperature sensing composite fire monitoring and alarm device; JCC type: Electrochemical energy storage power plant hydrogen, carbon monoxide, and smoke and temperature sensing composite fire monitoring and alarm device; JCD type: Electrochemical energy storage power plant carbon dioxide and smoke and temperature sensing composite fire monitoring and alarm device; JCE type: Electrochemical energy storage power plant hydrogen, carbon dioxide, and smoke and temperature sensing composite fire monitoring and alarm device; JCF type: Electrochemical energy storage power station suction type carbon monoxide and smoke sensing composite gas monitoring and alarm device; JCG type: Electrochemical energy storage power station suction type hydrogen, carbon monoxide, and smoke sensing composite gas monitoring and alarm device; JCH type: Electrochemical energy storage power station suction type carbon dioxide and smoke sensing composite gas monitoring and alarm device; JCI type: Electrochemical energy storage power station suction type hydrogen, carbon dioxide, and smoke sensing composite gas monitoring and alarm device. 4.3.2 Classified according to applicable electrochemical energy storage power stations: - Air cooled type: suitable for monitoring and alarm devices in air-cooled electrochemical energy storage power plants; Liquid cooled type: suitable for monitoring and alarm devices in liquid cooled electrochemical energy storage power plants. 4.3.3 Divided by applicable environment: - Ordinary type: suitable for electrochemical energy storage power plants with ambient temperatures ranging from -10 ℃ to 55 ℃; Special type: suitable for electrochemical energy storage power plants with ambient temperatures ranging from -40 ℃ to 70 ℃.
Contents of GB/T 46261-2025
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 46261-2025, GB 46261-2025, GBT 46261-2025, GB/T46261-2025, GB/T 46261, GB/T46261, GB46261-2025, GB 46261, GB46261, GBT46261-2025, GBT 46261, GBT46261