2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 6882-2016
GB/T 6882-2016   Acoustics--Determination of sound power levels and sound energy levels of noise sources using sound pressure--Precision methods for anechoic rooms and hemi-anechoic rooms (English Version)
Standard No.: GB/T 6882-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 25000 words Translation Price(USD):620.0 remind me the price change

Email:

Implemented on:2016-9-1 Delivery: via email in 1 business day

→ → →

,,2016-9-1,686241010280E4401457576158342
Standard No.: GB/T 6882-2016
English Name: Acoustics--Determination of sound power levels and sound energy levels of noise sources using sound pressure--Precision methods for anechoic rooms and hemi-anechoic rooms
Chinese Name: 声学 声压法测定噪声源声功率级和声能量级 消声室和半消声室精密法
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; MOH
Issued on: 2016-02-24
Implemented on: 2016-9-1
Status: valid
Superseding:GB/T 6882-2008 Acoustics - Determination of sound power levels of noise sources using pressure - Precision methods for anechoic and hemi-anechoic rooms
Target Language: English
File Format: PDF
Word Count: 25000 words
Translation Price(USD): 620.0
Delivery: via email in 1 business day
1 Scope 1.1 General This standard specifies the methods for measuring the sound pressure levels on a measurement surface enveloping a noise source (machinery or equipment) in an anechoic room or a hemi-anechoic room. The sound power level (and in case of impulsive or transient noise radiation, the sound energy level) of noise source in frequency bands of width one-third octave or with frequency weighting A applied, is calculated using those measurements, including corrections to allow for any differences between the meteorological conditions at the time and place of the test and those corresponding to a reference characteristic acoustic impedance. In general, the frequency range of interest is the one-third-octave bands with mid-band frequencies from 100Hz to 10,000Hz. As required, the range is extended or restricted to frequencies beyond or within these limits, to those between which the test room is qualified for the purpose of measurement. 1.2 Types of noise and noise sources The methods specified in this standard are suitable for all types of noise (steady, non-steady, fluctuating, isolated burst of sound energy, etc.) defined in GB/T 19052. The noise source under test can be a device, machine, component or sub-assembly. The maximum size of the noise source depends on specified requirements regarding the radius of the hypothetical sphere or hemisphere used as the enveloping measurement surface. 1.3 Test room The test rooms that are applicable for measurements made in accordance with this standard are an anechoic room or hemi-anechoic room, also called, respectively, a free-field test room or hemi-free-field test room. 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this standard, for measurements made in specified bands of frequency and with frequency weighting A applied. The uncertainty conforms to Accuracy Grade 1 in GB/T 19052-2003. 2 Normative References The following documents are indispensable for the application of this standard. For dated reference, only the edition cited applies. For undated reference, the latest edition (including any amendments) applies. GB/T 3785.1-2010 Electroacoustics — Sound Level Meters — Part 1: Specifications(IEC 61672-1:2002, IDT) GB/T 15173-2010 Electroacoustics — Sound Calibrators (IEC 60942:2003, IDT) GB/T 19052-2003 Acoustics - Noise Emitted by Machinery and Equipment-Rules for the Drafting and Presentation of A Noise Test Code (ISO 12001:1996, IDT) ISO 5725 (All Parts) [Accuracy (Trueness and Precision) of Measurement Methods and Results] SO 9613—1:1993 Acoustics — Attenuation of Sound during Propagation Outdoors — Part 1: Calculation of the Absorption of Sound by the Atmosphere) IEC 61183:1994 Electroacoustics — Random— Incidence and Diffuse — Field Calibration of Sound Level Meters IEC 61260:1995 Electroacoustics — Octave-band and Fractional—octave—band Filters ISO/IEC Guideline 98-3 Uncertainty Of Measurement — Part 3: Guide to the Expression of Uncertainty In Measurement (GUM:1995) 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply.
Foreword i Introduction iii 1 Scope 2 Normative References 3 Terms and Definitions 4 Reference Meteorological Conditions 5 Test Rooms 6 Instrumentation 7 Definition, Location, Installation and Operation of Noise Source Under Test 8 Measurement Surface 9 Determination of Sound Power Levels and Sound Energy Levels 10 Measurement Uncertainty 11 Information to be Recorded 12 Test Report Annex A (Normative) General Procedures for Qualification of Anechoic and Hemi-Anechoic Rooms Annex B (Normative) Qualification Procedure for Spaces Within Test Rooms Used in the Determination of Sound Power Levels and Sound Energy Levels of Specific Noise Sources Annex C (Normative) Calculation of A-Weighted Sound Power Levels And A-Weighted Sound Energy Levels from One-Third-Octave Band Levels Annex D (Normative) Array of Microphone Positions on A Spherical Measurement Surface in A Free Field Annex E (Normative) Arrays of Microphone Positions on A Hemispherical Measurement Surface in A Hemi-Free Field Annex F (Normative) Coaxial Circular Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex G (Normative) Meridional Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex H (Normative) Spiral Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex I (Informative) Guidance on the Development of Information on Measurement Uncertainty Annex NA (Informative) Test Room Design Guideline References
GB/T 6882-2016 is referred in:
*GB/T 9473-2017 Performance requirements for table lamps for paper task
*GB/T 15860-2011 General specification for compact disc players
*GB/T 17713-2011 Range hood
*GB/T 4214.1-2000 Acoustics--Household and similar electrical appliances--Test code for determination of airborne acoustical noise--Part 1:General requirements
Code of China
Standard
GB/T 6882-2016  Acoustics--Determination of sound power levels and sound energy levels of noise sources using sound pressure--Precision methods for anechoic rooms and hemi-anechoic rooms (English Version)
Standard No.GB/T 6882-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count25000 words
Price(USD)620.0
Implemented on2016-9-1
Deliveryvia email in 1 business day
Detail of GB/T 6882-2016
Standard No.
GB/T 6882-2016
English Name
Acoustics--Determination of sound power levels and sound energy levels of noise sources using sound pressure--Precision methods for anechoic rooms and hemi-anechoic rooms
Chinese Name
声学 声压法测定噪声源声功率级和声能量级 消声室和半消声室精密法
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; MOH
Issued on
2016-02-24
Implemented on
2016-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 6882-2008 Acoustics - Determination of sound power levels of noise sources using pressure - Precision methods for anechoic and hemi-anechoic rooms
Language
English
File Format
PDF
Word Count
25000 words
Price(USD)
620.0
Keywords
GB/T 6882-2016, GB 6882-2016, GBT 6882-2016, GB/T6882-2016, GB/T 6882, GB/T6882, GB6882-2016, GB 6882, GB6882, GBT6882-2016, GBT 6882, GBT6882
Introduction of GB/T 6882-2016
1 Scope 1.1 General This standard specifies the methods for measuring the sound pressure levels on a measurement surface enveloping a noise source (machinery or equipment) in an anechoic room or a hemi-anechoic room. The sound power level (and in case of impulsive or transient noise radiation, the sound energy level) of noise source in frequency bands of width one-third octave or with frequency weighting A applied, is calculated using those measurements, including corrections to allow for any differences between the meteorological conditions at the time and place of the test and those corresponding to a reference characteristic acoustic impedance. In general, the frequency range of interest is the one-third-octave bands with mid-band frequencies from 100Hz to 10,000Hz. As required, the range is extended or restricted to frequencies beyond or within these limits, to those between which the test room is qualified for the purpose of measurement. 1.2 Types of noise and noise sources The methods specified in this standard are suitable for all types of noise (steady, non-steady, fluctuating, isolated burst of sound energy, etc.) defined in GB/T 19052. The noise source under test can be a device, machine, component or sub-assembly. The maximum size of the noise source depends on specified requirements regarding the radius of the hypothetical sphere or hemisphere used as the enveloping measurement surface. 1.3 Test room The test rooms that are applicable for measurements made in accordance with this standard are an anechoic room or hemi-anechoic room, also called, respectively, a free-field test room or hemi-free-field test room. 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this standard, for measurements made in specified bands of frequency and with frequency weighting A applied. The uncertainty conforms to Accuracy Grade 1 in GB/T 19052-2003. 2 Normative References The following documents are indispensable for the application of this standard. For dated reference, only the edition cited applies. For undated reference, the latest edition (including any amendments) applies. GB/T 3785.1-2010 Electroacoustics — Sound Level Meters — Part 1: Specifications(IEC 61672-1:2002, IDT) GB/T 15173-2010 Electroacoustics — Sound Calibrators (IEC 60942:2003, IDT) GB/T 19052-2003 Acoustics - Noise Emitted by Machinery and Equipment-Rules for the Drafting and Presentation of A Noise Test Code (ISO 12001:1996, IDT) ISO 5725 (All Parts) [Accuracy (Trueness and Precision) of Measurement Methods and Results] SO 9613—1:1993 Acoustics — Attenuation of Sound during Propagation Outdoors — Part 1: Calculation of the Absorption of Sound by the Atmosphere) IEC 61183:1994 Electroacoustics — Random— Incidence and Diffuse — Field Calibration of Sound Level Meters IEC 61260:1995 Electroacoustics — Octave-band and Fractional—octave—band Filters ISO/IEC Guideline 98-3 Uncertainty Of Measurement — Part 3: Guide to the Expression of Uncertainty In Measurement (GUM:1995) 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply.
Contents of GB/T 6882-2016
Foreword i Introduction iii 1 Scope 2 Normative References 3 Terms and Definitions 4 Reference Meteorological Conditions 5 Test Rooms 6 Instrumentation 7 Definition, Location, Installation and Operation of Noise Source Under Test 8 Measurement Surface 9 Determination of Sound Power Levels and Sound Energy Levels 10 Measurement Uncertainty 11 Information to be Recorded 12 Test Report Annex A (Normative) General Procedures for Qualification of Anechoic and Hemi-Anechoic Rooms Annex B (Normative) Qualification Procedure for Spaces Within Test Rooms Used in the Determination of Sound Power Levels and Sound Energy Levels of Specific Noise Sources Annex C (Normative) Calculation of A-Weighted Sound Power Levels And A-Weighted Sound Energy Levels from One-Third-Octave Band Levels Annex D (Normative) Array of Microphone Positions on A Spherical Measurement Surface in A Free Field Annex E (Normative) Arrays of Microphone Positions on A Hemispherical Measurement Surface in A Hemi-Free Field Annex F (Normative) Coaxial Circular Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex G (Normative) Meridional Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex H (Normative) Spiral Paths of Microphones on A Hemispherical Measurement Surface in A Hemi-Free Field Annex I (Informative) Guidance on the Development of Information on Measurement Uncertainty Annex NA (Informative) Test Room Design Guideline References
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 6882-2016, GB 6882-2016, GBT 6882-2016, GB/T6882-2016, GB/T 6882, GB/T6882, GB6882-2016, GB 6882, GB6882, GBT6882-2016, GBT 6882, GBT6882