2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 10563-2006
JB/T 10563-2006   Technical specification for general purposes centrifugal fans (English Version)
Standard No.: JB/T 10563-2006 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2006-10-11 Delivery: via email in 1 business day

→ → →

,,2006-10-11,141137497011408ABDD2F4AB1CDCD
Standard No.: JB/T 10563-2006
English Name: Technical specification for general purposes centrifugal fans
Chinese Name: 一般用途离心通风机技术条件
Chinese Classification: J72    Compressor and fan
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 23.12 23.12    Ventilators. Fans. Air-conditioners 23.12
Source Content Issued by: Ministry of Railway
Issued on: 2006-7-27
Implemented on: 2006-10-11
Status: valid
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
1 Subject Contents and Applicable Scope This standard specifies the technical requirements, test methods, inspection rules, warranty period, marking, packing and transportation of general purposes centrifugal fans (hereinafter referred to as "fan"). This standard is applicable to centrifugal fans used in ventilation system, air conditioning and industrial production. Its transmission medium is air or gas mixture of air and other non-corrosive gases with a maximum total pressure not greater than 14.7kPa. The inlet temperature of the medium shall not be greater than 80℃, the dust content and other solid impurities content shall not be greater than 100mg/m3, the medium shall be free from viscous and fibrous matters. 2 Normative References GB/T 275 Shaft and Housing Fits for Rolling Bearings GB 1171 V Belts GB 1236 Method for Testing Air Performance of Fans GB 2888 Methods of Noise Measurement for Fans, Blowers Compressors and Roots Blowers GB 3181 Color Standard Sample for Paint Film GB 3235 Basic Types Sizes Parameters and Characteristics Curve of Fans GB 4323 Pin Coupling with Elastic Sleeve GB 10178 Site Testing of Fans ZB J72 038 Fan Welding Inspection ZB J72 039 Specification of Riveting and Welding Part for Fans ZB J72 042 Fan Rotor Balance JB 8 Manufacturer's Plate 3 Technical Requirements
1 Subject Contents and Applicable Scope 2 Normative References 3 Technical Requirements 4 Test Methods 5 Inspection Rules 6 Warranty Period 7 Marking, Packaging, and Transportation Additional Information:
Referred in JB/T 10563-2006:
*GB/T 275-2015 Rolling bearings―Fits
*GB 1171-1989 Classical V-belts
*GB 1236-1985
*GB 2888-1982
*GB 3181-1982 Color standard samples for films of paint
*GB3235-
*GB4323-
*GB10178-
*ZBJ72-
*ZBJ72-
*ZBJ72-
*JB 8-1982
JB/T 10563-2006 is referred in:
*GB/T 36699-2018 Specification for liquid fuels and gaseous fuels burners of boilers
*GB/T 6197-2024 Wood based panel machinery—Veneer dryer
Code of China
Standard
JB/T 10563-2006  Technical specification for general purposes centrifugal fans (English Version)
Standard No.JB/T 10563-2006
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)80.0
Implemented on2006-10-11
Deliveryvia email in 1 business day
Detail of JB/T 10563-2006
Standard No.
JB/T 10563-2006
English Name
Technical specification for general purposes centrifugal fans
Chinese Name
一般用途离心通风机技术条件
Chinese Classification
J72
Professional Classification
JB
ICS Classification
Issued by
Ministry of Railway
Issued on
2006-7-27
Implemented on
2006-10-11
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
80.0
Keywords
JB/T 10563-2006, JB 10563-2006, JBT 10563-2006, JB/T10563-2006, JB/T 10563, JB/T10563, JB10563-2006, JB 10563, JB10563, JBT10563-2006, JBT 10563, JBT10563
Introduction of JB/T 10563-2006
1 Subject Contents and Applicable Scope This standard specifies the technical requirements, test methods, inspection rules, warranty period, marking, packing and transportation of general purposes centrifugal fans (hereinafter referred to as "fan"). This standard is applicable to centrifugal fans used in ventilation system, air conditioning and industrial production. Its transmission medium is air or gas mixture of air and other non-corrosive gases with a maximum total pressure not greater than 14.7kPa. The inlet temperature of the medium shall not be greater than 80℃, the dust content and other solid impurities content shall not be greater than 100mg/m3, the medium shall be free from viscous and fibrous matters. 2 Normative References GB/T 275 Shaft and Housing Fits for Rolling Bearings GB 1171 V Belts GB 1236 Method for Testing Air Performance of Fans GB 2888 Methods of Noise Measurement for Fans, Blowers Compressors and Roots Blowers GB 3181 Color Standard Sample for Paint Film GB 3235 Basic Types Sizes Parameters and Characteristics Curve of Fans GB 4323 Pin Coupling with Elastic Sleeve GB 10178 Site Testing of Fans ZB J72 038 Fan Welding Inspection ZB J72 039 Specification of Riveting and Welding Part for Fans ZB J72 042 Fan Rotor Balance JB 8 Manufacturer's Plate 3 Technical Requirements
Contents of JB/T 10563-2006
1 Subject Contents and Applicable Scope 2 Normative References 3 Technical Requirements 4 Test Methods 5 Inspection Rules 6 Warranty Period 7 Marking, Packaging, and Transportation Additional Information:
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 10563-2006, JB 10563-2006, JBT 10563-2006, JB/T10563-2006, JB/T 10563, JB/T10563, JB10563-2006, JB 10563, JB10563, JBT10563-2006, JBT 10563, JBT10563