JB/T 501-2006   Test guide for power transformers (English Version)
Standard No.: JB/T 501-2006 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 24000 words Price(USD):480.0 remind me the price change

Email:

Implemented on:2006-10-1 Delivery: via email in 1 business day
,,
Standard No.: JB/T 501-2006
English Name: Test guide for power transformers
Chinese Name: 电力变压器试验导则
Chinese Classification: K41    Transformer
Professional Classification: JB    Professional Standard - Machinery
Issued by: NDRC
Issued on: 2006-5-6
Implemented on: 2006-10-1
Status: superseded
Superseded by:JB/T 501-2021 Test guide for power transformers
Superseded on:2021-10-1
Superseding:JB/T 501-1991
Language: English
File Format: PDF
Word Count: 24000 words
Price(USD): 480.0
Delivery: via email in 1 business day
Test guide for power transformers 1 Scope This standard specifies procedures and methods of routine tests, type tests and special tests for oil-immersed type and dry-type power transformers. This standard applies to the tests of oil-immersed type and dry-type power transformers. This standard may apply to special transformers. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding any corrigendum), or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the latest editions of the standards indicated below. For undated references, the latest edition of the document referred to applies. GB/T 311.6-1983 High voltage test techniques—Part 5: Sphere-gaps for voltage measurement (eqv IEC 60052:1960) GB/T 507-2002 Insulating liquids—Determination of the breakdown voltage at power frequency (eqv IEC 60156:1995) GB 1094.1-1996 Power transformers—Part 1: General (eqv IEC 60076-1:1993) GB 1094.2-1996 Power transformers—Part 2: Temperature rise (eqv IEC 60076-2:1993) GB 1094.3-2003 Power transformers—Part 3:Insulation levels, dielectric tests and external clearances in air (eqv IEC 60076-3:2000) GB/T 1094.4-2005 Power transformers—Part 4:Guide to the lightning impulse and switching impulse testing—Power transformers and reactors (IEC 60076-4:2002, MOD) GB 1094.5 Power transformers—Part 5: Ability to withstand short circuit (GB 1094.5-2003, IEC 69076-5:2000, MOD) GB/T 1094.10 Power transformers—Part 10: Determination of sound levels (GB/T 1094.10-2003, IEC 60076-10:2001, MOD) GB/T 5654-1985 Measurement of relative permittivity, dielectric dissipation factor at power frequency and volume resistivity of insulating liquids GB 6450 Dry-type power transformers (GB 6450-1986, eqv IEC 60726:1982) GB/T 6451-19 Specification and technical requirements for three-phase oil-immersed power transformers GB 7597-1987 Method of sampling for transformer and turbine oils in electric power industry GB/T 7600-1987 Determination of water content in transformer oils in service by coulometric method GB/T 7601-1987 Determination of water content in transformer oils in service by gas chromatographic method GB/T 10228-1997 Specification and technical requirements for dry-type power transformers GB/T 16274-1996 Specification and technical requirements for oil immersed power transformers 500kV GB/T 16927.1-1997 High voltage test techniques—Part 1: General test requirements (eqv IEC 60060-1:1989) GB/T 17623-1998 Determination of componental contents of gases dissolved in insulating oil by gas chromatography method DL/T 423-1991 Determination of air content in insulating oil by vacuum differential pressure method 3 Main symbols Ur—rated voltage, V; Ir—rated current, A; Sr—rated power, kVA; K—voltage ratio; R—resistance, Ω; T—temperature, ℃; Rxg—phase resistance, Ω; Rxn—line resistance, Ω; Kδ—air density correction factor; Kd—air density; fr—rated frequency, Hz; P0—no-load loss, W ; I0—no-load current, %; Pk—load loss corrected to reference temperature, W; Zk—short-circuit impedance corrected to reference temperature, %; Zi—short-circuit impedance, Ω; Pr—resistance loss, W; θp—average temperature, ℃; Δθ—temperature rise, K; Z0—zero sequence impedance, Ω/phase; Zs—system impedance, Ω. 4 Test procedure This test procedure is not standardized. The items with the test type not indicated are routine tests. To be specific, the following items are included. a) Strength test of oil tank (type test); b) Oil tank leak test; c) Measurement of dielectric characteristics: 1) Determinations of insulation resistance, absorption ratio and polarization index (for transformers of 35kV, 4,000kVA and above, 66kV and above, the insulation resistance and absorption ratio shall be given; for those of 330kV and above, the insulation resistance value, absorption ratio and polarization index shall be given; for other small and medium-sized transformers, only the insulation resistance value is given); 2) Measurement of dielectric dissipation factor (for those of 35kV, 8,000kVA and above, and 66kV and above). d) Transformer oil test:
Contents Foreword i 1 Scope 2 Normative references 3 Main symbols 4 Test procedure 5 Oil tank leak test (routine test) 5.1 General requirements 5.2 Test purpose 5.3 Test method 5.4 Judgment of test results 6 Measurement of dielectric characteristics (routine test) 6.1 Test purpose and items 6.2 Measurement of insulation resistance, absorption ratio and polarization index 6.3 Measurement of dielectric dissipation factor 7 Transformer oil test (routine test) 7.1 Measurement of breakdown voltage 7.2 Measurement of dielectric dissipation factor 7.3 Determination of moisture content 7.4 Determination of air content 7.5 Gas chromatographic analysis of dissolved gas 8 Voltage ratio measurement (routine test) 9 Calibration of voltage vector relation (routine test) 9.1 Voltage ratio bridge method 9.2 Double voltmeter method 9.3 Tester method 10 Winding resistance measurement (routine test) 11 Insulation tests (routine, type and special tests) 11.1 General 11.2 Switching impulse and lightning impulse tests 11.3 Applied voltage withstand test (routine test) 11.4 Short-duration induced over voltage withstand test (ACSD) 11.5 Long-duration induced AC voltage withstand test (ACLD) 11.6 Induced over voltage withstand test of dry-type transformer 12 Partial discharge measurement (routine test) 13 Measurement of no-load loss and current (routine test) 14 Measurement of short-circuit impedance and load loss (routine test) 15 On-load tap-changer test (routine test) 15.1 Operation test 15.2 Auxiliary circuits insulation test 16 Temperature rise test (type test) 17 Mechanical strength test of oil tank (type test) 17.1 Test purpose 17.2 Test methods 17.3 Judgment of results 17.4 Precautions 18 Determination of sound levels (special test) 19 Measurement of zero-sequence impedance of three-phase transformer (special test) 19.1 General 19.2 Measurement of zero-sequence impedance with balanced ampere turns 19.3 Measurement of zero-sequence impedance without balanced ampere turn 20 Test on ability to withstand short circuit (special test) 21 Measurement of no-load current harmonic (special test) 22 Measurement of power absorbed by fan and oil pump motor (special test) 22.1 Preparation before test 22.2 Test methods 22.3 Precautions
Referred in JB/T 501-2006:
*GB/T 311.6-1983 High voltage test techniques; Part 5:Sphere-gaps for voltage measurement
*GB/T 507-2002 Insulating liquids--Determination of the breakdown voltage at power frequency
*GB 1094.1-1996 Power transformers - Part 1: General
*GB 1094.2-1996 Power transformers - Part 2: Temperature rise
*GB 1094.3-2003 Power transformers?Part 3:Insulation levels,dielectric tests and external clearances in air
*GB/T 1094.4-2005 Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors
*GB 1094.5-2008 Power transformers - Part 5: Ability to withstand short circuit
*GB/T 1094.10-2003 Power transformers - Part 10: Determination of sound
*GB/T 5654-1985 Measurement of relative permittivity,dielectric dissipation factor at power frequency and volume resistivity of insulating liquids
*GB 6450-1986 Dry-type power transformers
*GBT6451-1919
*GB 7597-1987 Method of sampling for transformer and turbine oils inelectric power industry
*GB/T 7600-1987
*GB/T 7601-1987
*GB/T 10228-1997 Specification and technical requirements for dry-trpe power transformers
*GB/T 16274-1996 Specification and technical requirements for oil immersed power transformers 500kV
*GB/T 16927.1-1997 Hign voltsge test techniques - Part 1: General test requirements
*GB/T 17623-1998 Determination of componental contents of gases dissolved in insulating oil by gas chromatography method
*DL/T 423-1991 Determination of Dissolved Gas Content in Insulating Oil Method of Vacuum Pressure Difference
JB/T 501-2006 is referred in:
* GB/T 17468-2008 The Guide for Choice Power Transformers
* Q/GDW 731-2012 Selection Guide for On-load Capacity Regulating Power Transformer
Code of China
Standard
JB/T 501-2006   Test guide for power transformers (English Version)
Standard No.JB/T 501-2006
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count24000 words
Price(USD)480.0
Implemented on2006-10-1
Deliveryvia email in 1 business day
Detail of JB/T 501-2006
Standard No.
JB/T 501-2006
English Name
Test guide for power transformers
Chinese Name
电力变压器试验导则
Chinese Classification
K41
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2006-5-6
Implemented on
2006-10-1
Status
superseded
Superseded by
JB/T 501-2021 Test guide for power transformers
Superseded on
2021-10-1
Abolished on
Superseding
JB/T 501-1991
Language
English
File Format
PDF
Word Count
24000 words
Price(USD)
480.0
Keywords
JB/T 501-2006, JB 501-2006, JBT 501-2006, JB/T501-2006, JB/T 501, JB/T501, JB501-2006, JB 501, JB501, JBT501-2006, JBT 501, JBT501
Introduction of JB/T 501-2006
Test guide for power transformers 1 Scope This standard specifies procedures and methods of routine tests, type tests and special tests for oil-immersed type and dry-type power transformers. This standard applies to the tests of oil-immersed type and dry-type power transformers. This standard may apply to special transformers. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding any corrigendum), or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the latest editions of the standards indicated below. For undated references, the latest edition of the document referred to applies. GB/T 311.6-1983 High voltage test techniques—Part 5: Sphere-gaps for voltage measurement (eqv IEC 60052:1960) GB/T 507-2002 Insulating liquids—Determination of the breakdown voltage at power frequency (eqv IEC 60156:1995) GB 1094.1-1996 Power transformers—Part 1: General (eqv IEC 60076-1:1993) GB 1094.2-1996 Power transformers—Part 2: Temperature rise (eqv IEC 60076-2:1993) GB 1094.3-2003 Power transformers—Part 3:Insulation levels, dielectric tests and external clearances in air (eqv IEC 60076-3:2000) GB/T 1094.4-2005 Power transformers—Part 4:Guide to the lightning impulse and switching impulse testing—Power transformers and reactors (IEC 60076-4:2002, MOD) GB 1094.5 Power transformers—Part 5: Ability to withstand short circuit (GB 1094.5-2003, IEC 69076-5:2000, MOD) GB/T 1094.10 Power transformers—Part 10: Determination of sound levels (GB/T 1094.10-2003, IEC 60076-10:2001, MOD) GB/T 5654-1985 Measurement of relative permittivity, dielectric dissipation factor at power frequency and volume resistivity of insulating liquids GB 6450 Dry-type power transformers (GB 6450-1986, eqv IEC 60726:1982) GB/T 6451-19 Specification and technical requirements for three-phase oil-immersed power transformers GB 7597-1987 Method of sampling for transformer and turbine oils in electric power industry GB/T 7600-1987 Determination of water content in transformer oils in service by coulometric method GB/T 7601-1987 Determination of water content in transformer oils in service by gas chromatographic method GB/T 10228-1997 Specification and technical requirements for dry-type power transformers GB/T 16274-1996 Specification and technical requirements for oil immersed power transformers 500kV GB/T 16927.1-1997 High voltage test techniques—Part 1: General test requirements (eqv IEC 60060-1:1989) GB/T 17623-1998 Determination of componental contents of gases dissolved in insulating oil by gas chromatography method DL/T 423-1991 Determination of air content in insulating oil by vacuum differential pressure method 3 Main symbols Ur—rated voltage, V; Ir—rated current, A; Sr—rated power, kVA; K—voltage ratio; R—resistance, Ω; T—temperature, ℃; Rxg—phase resistance, Ω; Rxn—line resistance, Ω; Kδ—air density correction factor; Kd—air density; fr—rated frequency, Hz; P0—no-load loss, W ; I0—no-load current, %; Pk—load loss corrected to reference temperature, W; Zk—short-circuit impedance corrected to reference temperature, %; Zi—short-circuit impedance, Ω; Pr—resistance loss, W; θp—average temperature, ℃; Δθ—temperature rise, K; Z0—zero sequence impedance, Ω/phase; Zs—system impedance, Ω. 4 Test procedure This test procedure is not standardized. The items with the test type not indicated are routine tests. To be specific, the following items are included. a) Strength test of oil tank (type test); b) Oil tank leak test; c) Measurement of dielectric characteristics: 1) Determinations of insulation resistance, absorption ratio and polarization index (for transformers of 35kV, 4,000kVA and above, 66kV and above, the insulation resistance and absorption ratio shall be given; for those of 330kV and above, the insulation resistance value, absorption ratio and polarization index shall be given; for other small and medium-sized transformers, only the insulation resistance value is given); 2) Measurement of dielectric dissipation factor (for those of 35kV, 8,000kVA and above, and 66kV and above). d) Transformer oil test:
Contents of JB/T 501-2006
Contents Foreword i 1 Scope 2 Normative references 3 Main symbols 4 Test procedure 5 Oil tank leak test (routine test) 5.1 General requirements 5.2 Test purpose 5.3 Test method 5.4 Judgment of test results 6 Measurement of dielectric characteristics (routine test) 6.1 Test purpose and items 6.2 Measurement of insulation resistance, absorption ratio and polarization index 6.3 Measurement of dielectric dissipation factor 7 Transformer oil test (routine test) 7.1 Measurement of breakdown voltage 7.2 Measurement of dielectric dissipation factor 7.3 Determination of moisture content 7.4 Determination of air content 7.5 Gas chromatographic analysis of dissolved gas 8 Voltage ratio measurement (routine test) 9 Calibration of voltage vector relation (routine test) 9.1 Voltage ratio bridge method 9.2 Double voltmeter method 9.3 Tester method 10 Winding resistance measurement (routine test) 11 Insulation tests (routine, type and special tests) 11.1 General 11.2 Switching impulse and lightning impulse tests 11.3 Applied voltage withstand test (routine test) 11.4 Short-duration induced over voltage withstand test (ACSD) 11.5 Long-duration induced AC voltage withstand test (ACLD) 11.6 Induced over voltage withstand test of dry-type transformer 12 Partial discharge measurement (routine test) 13 Measurement of no-load loss and current (routine test) 14 Measurement of short-circuit impedance and load loss (routine test) 15 On-load tap-changer test (routine test) 15.1 Operation test 15.2 Auxiliary circuits insulation test 16 Temperature rise test (type test) 17 Mechanical strength test of oil tank (type test) 17.1 Test purpose 17.2 Test methods 17.3 Judgment of results 17.4 Precautions 18 Determination of sound levels (special test) 19 Measurement of zero-sequence impedance of three-phase transformer (special test) 19.1 General 19.2 Measurement of zero-sequence impedance with balanced ampere turns 19.3 Measurement of zero-sequence impedance without balanced ampere turn 20 Test on ability to withstand short circuit (special test) 21 Measurement of no-load current harmonic (special test) 22 Measurement of power absorbed by fan and oil pump motor (special test) 22.1 Preparation before test 22.2 Test methods 22.3 Precautions
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 501-2006, JB 501-2006, JBT 501-2006, JB/T501-2006, JB/T 501, JB/T501, JB501-2006, JB 501, JB501, JBT501-2006, JBT 501, JBT501