Standard No.: JB/T 7387-2014
English Name: Electrical Control Valves for Industrial - Process Control Systems
Chinese Name: 工业过程控制系统用电动控制阀
Professional Classification: JB    Professional Standard - Machinery
Issued by: Ministry of Industry and Information Technology
Issued on: 2014-05-06
Implemented on: 2014-10-1
Status: valid
Superseding:JB/T 7387-1994 Electrical control valves for industrial-process control systems
Language: English
File Format: PDF
Word Count: 9000 words
Price(USD): 220.0
Delivery: via email in 1 business day
1 Scope This standard specifies product classification, basic parameters, requirements, test methods, inspection rules, marking, packaging and storage of electrical control valves for industrial-process control systems (also referred to as electric regulator). This standard is applicable to various electrical control valves (hereinafter referred to as control valve) consisting of electric actuator and valves that are in conformity with JB/T 8219. This standard is not applicable to control valves having specific requirements such as operating under radiation conditions. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. GB/T 13384 General Specifications for Packing of Mechanical and Electrical Product GB/T 17213.3 Industrial-Process Control Valves—Part 3-1: Dimensions—Face-to-face Dimensions for Flanged, Two-way, Globe-type, Straight Pattern and Center-to-face Dimensions for Flanged, Two-way, Globe-type, Angle Pattern Control Valves GB/T 17213.11 Industrial-Process Control Valves—Part 3-2: Dimensions—Face-to-face Dimensions for Rotary Control Valves Except Butterfly Valves GB/T 17213.12 Industrial-Process Control Valves—Part 3-3: Dimensions—End-to-end Dimensions for Buttweld, Two-way, Globe-type, Straight Pattern Control Valves GB/T 18271.1-2000 Process Measurement and Control Devices—General Methods and Procedures for Evaluating Performance—Part 1: General Considerations GB/T 26815-2011 Terminologies for Industrial-Process Measurement and Control Instruments—Terms of Final Controlling Elements JB/T 8219 Electrical Actuators for Industrial-Process Measurement and Control Systems 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 26815-2011 apply. 4 Product Classification and Basic Parameters 4.1 Product classification 4.1.1 By actuation mode Classification by actuation mode of control valve:
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 5 Requirements 6 Test Method 7 Inspection Rules 8 Marking, Packaging and Storage Bibliography Figure 1 Tapping Table 1 Error Limit of Control Valve Table 2 Maximum Seat Leakage Table 3 Leakage Coefficient Table 4 Calculation Formulae of Rated Valve Capacity Table 5 Slope Deviation of Linear Flow Characteristic Table 6 Slope Deviation of Equal Percentage Flow Characteristic Table 7 Size of Standard Test Section Table 8 Inspection Items
Referred in JB/T 7387-2014:
*GB/T 13384-2008 General specifications for packing of mechanical and electrical product
*GB/T 17213.3-2005 Industrial-process control valves—Part 3-1:Dimensions—Face-to-face dimensions for flanged,two-way,globe-type,straight pattern and center-to-face dimensions for flanged,two-way,globe-type,angle pattern control valves
*GB/T 17213.11-2005 Industrial-process control valves - Part 3-2 : Dimensions - Face to face dimensions for rotary control valves except butterfly valves
*GB/T 17213.12-2005 Industrial-process control valves—Part 3-3:Dimensions—End-to-end dimensions for buttweld,two-way,globe-type,straight pattern control valves
*GB/T 18271.1-2000 Proccess measurement and control devices--General methods and procedures for evaluating performance--Part 1:General considerations
*GB/T 26815-2011 Terminologies for industrial process measurement and control instruments - Terms of final controlling elements
*JB/T 8219-2016 Conventional and intelligent electrical actuators for industrial-process control systems
Code of China
Standard
JB/T 7387-2014  Electrical Control Valves for Industrial - Process Control Systems (English Version)
Standard No.JB/T 7387-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)220.0
Implemented on2014-10-1
Deliveryvia email in 1 business day
Detail of JB/T 7387-2014
Standard No.
JB/T 7387-2014
English Name
Electrical Control Valves for Industrial - Process Control Systems
Chinese Name
工业过程控制系统用电动控制阀
Chinese Classification
Professional Classification
JB
ICS Classification
Issued by
Ministry of Industry and Information Technology
Issued on
2014-05-06
Implemented on
2014-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JB/T 7387-1994 Electrical control valves for industrial-process control systems
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
220.0
Keywords
JB/T 7387-2014, JB 7387-2014, JBT 7387-2014, JB/T7387-2014, JB/T 7387, JB/T7387, JB7387-2014, JB 7387, JB7387, JBT7387-2014, JBT 7387, JBT7387
Introduction of JB/T 7387-2014
1 Scope This standard specifies product classification, basic parameters, requirements, test methods, inspection rules, marking, packaging and storage of electrical control valves for industrial-process control systems (also referred to as electric regulator). This standard is applicable to various electrical control valves (hereinafter referred to as control valve) consisting of electric actuator and valves that are in conformity with JB/T 8219. This standard is not applicable to control valves having specific requirements such as operating under radiation conditions. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. GB/T 13384 General Specifications for Packing of Mechanical and Electrical Product GB/T 17213.3 Industrial-Process Control Valves—Part 3-1: Dimensions—Face-to-face Dimensions for Flanged, Two-way, Globe-type, Straight Pattern and Center-to-face Dimensions for Flanged, Two-way, Globe-type, Angle Pattern Control Valves GB/T 17213.11 Industrial-Process Control Valves—Part 3-2: Dimensions—Face-to-face Dimensions for Rotary Control Valves Except Butterfly Valves GB/T 17213.12 Industrial-Process Control Valves—Part 3-3: Dimensions—End-to-end Dimensions for Buttweld, Two-way, Globe-type, Straight Pattern Control Valves GB/T 18271.1-2000 Process Measurement and Control Devices—General Methods and Procedures for Evaluating Performance—Part 1: General Considerations GB/T 26815-2011 Terminologies for Industrial-Process Measurement and Control Instruments—Terms of Final Controlling Elements JB/T 8219 Electrical Actuators for Industrial-Process Measurement and Control Systems 3 Terms and Definitions For the purposes of this document, the terms and definitions given in GB/T 26815-2011 apply. 4 Product Classification and Basic Parameters 4.1 Product classification 4.1.1 By actuation mode Classification by actuation mode of control valve:
Contents of JB/T 7387-2014
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Classification and Basic Parameters 5 Requirements 6 Test Method 7 Inspection Rules 8 Marking, Packaging and Storage Bibliography Figure 1 Tapping Table 1 Error Limit of Control Valve Table 2 Maximum Seat Leakage Table 3 Leakage Coefficient Table 4 Calculation Formulae of Rated Valve Capacity Table 5 Slope Deviation of Linear Flow Characteristic Table 6 Slope Deviation of Equal Percentage Flow Characteristic Table 7 Size of Standard Test Section Table 8 Inspection Items
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 7387-2014, JB 7387-2014, JBT 7387-2014, JB/T7387-2014, JB/T 7387, JB/T7387, JB7387-2014, JB 7387, JB7387, JBT7387-2014, JBT 7387, JBT7387